JJG 131-2004Verification Regulation of the Electric Contact Mercury-in-Glass Thermometers (English PDF)
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for JJG 131-2004 in 30 minutes.
Issued by
The General Administration of Quality Supervision, Inspection and Quarantine issued, This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on March 2,.2004, and
Level / Type
National · Mandatory
Issue date
March 2, 2004
Implementation date
September 2, 2004
Scope
JJG 131-2004 (Verification Regulation of the Electric Contact Mercury-in-Glass Thermometers) is available as an English-translated PDF.
JJG 131-2004 — This standard applies to measurement range of -30 �� ~ 300 �� for various range of electric contact glass mercury thermometer (hereinafter referred to as the thermometer) the initial verification, testing and use of follow-up inspection.
Found what you need?
Document preview — JJG 131-2004
National Standard of the People's Republic of China
- ICS
- 17.200
- Classification
- A 54
- Replacing
- JJG 131-1991
Issued by: The General Administration of Quality Supervision, Inspection and Quarantine issued, This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on March 2,.2004, and
Contents
- 1 Scope (1)
- 2 Citations (1)
- 3 Terms (1)
- 4 Overview (1)
- 4.1 Principles (1)
- 4.2 Construction (1)
- 5 Metrological performance requirements (2)
- 5.1 Indication stability (2)
- 5.2 Indication error (4)
- 5.3 Motion Error (4)
- 5.4 Insensitive area (4)
- 6 General technical requirements (4)
- 6.1 Scales and signs (4)
- 6.2 Glass casing, temperature sensitive bulbs and capillary tubes (5)
- 6.3 Temperature and temperature sensitive liquid column (5)
- 6.4 Adjusting device (5)
- 7 Measuring instrument control (5)
- 7.1 Verification conditions (5)
- 7.2 Verification project (5)
- 7.3 Verification method (5)
- 7.4 Processing of verification results (8)
- 7.5 Verification cycle (8)
- Appendix A Electric Contact Glass Mercury Thermometer Verification Certificate (inside page) format (9)
- Appendix B Electric Contact Glass Mercury Thermometer Verification Result Notification (inside page) format (10)
- Appendix C Evaluation of Uncertainty in Measurement Results of Temperature Correction Value of Electrical Contact Glass Mercury Thermometer (11)
1 Scope (1)
2 Citations (1)
3 Terms (1)
4 Overview (1)
4.1 Principles (1)
4.2 Construction (1)
5 Metrological performance requirements (2)
5.1 Indication stability (2)
5.2 Indication error (4)
5.3 Motion Error (4)
5.4 Insensitive area (4)
6 General technical requirements (4)
6.1 Scales and signs (4)
6.2 Glass casing, temperature sensitive bulbs and capillary tubes (5)
6.3 Temperature and temperature sensitive liquid column (5)
6.4 Adjusting device (5)
7 Measuring instrument control (5)
7.1 Verification conditions (5)
7.2 Verification project (5)
7.3 Verification method (5)
7.4 Processing of verification results (8)
7.5 Verification cycle (8)
Appendix A Electric Contact Glass Mercury Thermometer Verification Certificate (inside page) format (9)
Appendix B Electric Contact Glass Mercury Thermometer Verification Result Notification (inside page) format (10)
Appendix C Evaluation of Uncertainty in Measurement Results of Temperature Correction Value of Electrical Contact Glass Mercury Thermometer (11)
Electric contact glass mercury thermometer verification procedures
1 Scope
This procedure is applicable to electrical contact glass mercury thermometers with various ranges ranging from -30 °C to 300 °C.
The first verification, subsequent verification and in-use inspection of the thermometer are referred to below. Fixed-point thermometer without scale can refer to this procedure is calibrated or tested.
2 Citations
Citations to this procedure JB/T 9264-1999 "Electrical Contact Glass Thermometer" Use of this procedure should take care to use the current valid version of the above cited documents.
3 terms
Scale. A combination of a set of lines, numbers, and unit of measure (°C) on a thermometer to indicate temperature values.
Scale plate. The internal standard glass thermometer is printed with a flat, colored (such as milky white) sheet.
Scale line. A line imprinted on a glass rod or scale to indicate temperature values.
Scale value. A number imprinted on a glass rod or scale to indicate the temperature value.
Master scale. The scale of the measurement range section.
Auxiliary scale. The scale set for measuring the zero indication.
Excavation line. scale line other than the upper and lower limits.
Immersion line. A rod-type immersion thermometer is used to indicate the marking line of the immersion position.
Exposing the liquid column. The thermometer is exposed to the liquid column outside the measured medium during the measurement.
Intermediate bubble. an enlarged part of the inner diameter of the capillary, which functions to accommodate part of the temperature sensitive liquid in order to shorten the length of the capillary degree.
Safety bubble. the enlarged part of the top of the capillary, the role is when the measured temperature exceeds the upper limit of the thermometer when protecting the thermometer, it will not be damaged.
4 Overview
4.1 Principle
The electric contact glass mercury thermometer is used to change the temperature of the mercury in the transparent glass bulb and the capillary.
The effect of thermal expansion and contraction is to measure the temperature. There are two contacts in the thermometer, one on the temperature-sensitive mercury column.
The end face, the other is at any set position of the scale plate. When the ambient temperature changes, the temperature of the mercury column rises or falls.
Drop, causing the two contacts to turn on or off. The electrical equipment can be controlled by the supporting control device.
4.2 Construction
The thermometer is divided into two types. adjustable and fixed. Commonly adjustable and fixed construction diagrams are shown in Figure 1 and
Figure 2 shows.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
How to Download JJG 131-2004
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
Secure payment via Stripe
Payments accepted
JJG 131-2004
$235.00