JJG 1170-2019Automatic Quantitative Loading Vehicle Systems (English PDF)
自动定量装车系统检定规程
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for JJG 1170-2019 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2019
Implementation date
March 31, 2020
Scope
JJG 1170-2019 is the English-translated version of 自动定量装车系统检定规程.
JJG 1170-2019 is the Chinese standard "Automatic Quantitative Loading Vehicle Systems".
Found what you need?
Document preview — JJG 1170-2019
National Standard of the People's Republic of China
- ICS
- 17.100
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Reference documents (1)
- 3 Terms and measurement units (1)
- 3.1 Term (1)
- 3.2 Unit of measurement (3)
- 4 Overview (3)
- 5 Measurement performance requirements (3)
- 5.1 Accuracy level (3)
- 5.2 Maximum allowable error (3)
- 5.3 Cumulative division value (dt) (4)
- 6 General technical requirements (4)
- 6.1 Adaptability of use (4)
- 6.2 Operational safety (4)
- 6.3 Indication device for weighing results (4)
- 6.4 Zero-setting device(5)
- 6.5 Descriptive marks (5)
- 6.6 Verification mark (6)
- 7 Measuring instrument control (6)
- 7.1 Verification conditions (6)
- 7.2 Verification items and verification methods (7)
- 8 Processing of verification results (13)
- 9 Verification period (13)
- Appendix A Verification Record Format--Separation Verification Method (Recommendation) (14)
- Appendix B Verification Record Format---Integrated Verification Method (Recommendation) (16)
- Appendix C Format of the inner page of the verification certificate (recommended) (18)
- Appendix D Inner Page Format of the Verification Result Notice (Recommendation) (19)
1 Scope (1)
2 Reference documents (1)
3 Terms and measurement units (1)
3.1 Term (1)
3.2 Unit of measurement (3)
4 Overview (3)
5 Measurement performance requirements (3)
5.1 Accuracy level (3)
5.2 Maximum allowable error (3)
5.3 Cumulative division value (dt) (4)
6 General technical requirements (4)
6.1 Adaptability of use (4)
6.2 Operational safety (4)
6.3 Indication device for weighing results (4)
6.4 Zero-setting device(5)
6.5 Descriptive marks (5)
6.6 Verification mark (6)
7 Measuring instrument control (6)
7.1 Verification conditions (6)
7.2 Verification items and verification methods (7)
8 Processing of verification results (13)
9 Verification period (13)
Appendix A Verification Record Format--Separation Verification Method (Recommendation) (14)
Appendix B Verification Record Format---Integrated Verification Method (Recommendation) (16)
Appendix C Format of the inner page of the verification certificate (recommended) (18)
Appendix D Inner Page Format of the Verification Result Notice (Recommendation) (19)
Introduction
This regulation is mainly based on OIMLR1072007 (E) "Discontinuous cumulative automatic weighing instrument (cumulative hopper scale)" system Part of the content refers to OIMLR612004 (E) "Gravity Automatic Loading Scale".
This regulation is drafted in accordance with the rules of JJF1002-2010 "National Metrological Verification Regulations Compilation Rules".
The circumstances under which this regulation adopts international recommendations are as follows.
---Accuracy level adopts OIMLR107 "Discontinuous cumulative automatic weighing instrument" (5.1);
---The maximum allowable error between single loading and preset value refers to OIMLR61 "Gravity Automatic Loading Scale" (5.2.1);
---The maximum allowable error of cumulative charging adopts OIMLR107 "Discontinuous cumulative automatic weighing instrument" (5.2.2);
---The cumulative division value adopts OIMLR107 "Discontinuous cumulative automatic weighing instrument" (5.3);
--- For technical requirements, refer to OIMLR107 "Discontinuous Cumulative Automatic Weighing Apparatus" (6.1~6.6);
--- Refer to OIMLR107 "Discontinuous Accumulative Automatic Weighing Apparatus" (7.2) for verification items and methods.
This regulation is issued for the first time.
Automatic quantitative loading system
1 Scope
This regulation is applicable to the first verification, subsequent verification and in-use inspection of the automatic quantitative loading system.
2 Reference documents this regulation refers to the following documents.
JJG 99 weight
JJF1001 general measurement terms and definitions JJF1181 Weighing instrument measurement terms and definitions OIMLR61.2004 (E) Gravity automatic filling weighing instrument (AutomaticGravimetricFilingIn-struments) OIMLR76-1.2006 (E) Non-automatic weighing instrument Part 1: Metrology and technical requirements-test (Non-automaticWeighingInstrumentsPart 1.MetrologicalandTechnicalRequirement-Test) OIMLR107.2007 (E) Discontinuous cumulative automatic weighing instrument (cumulative hopper scale) (DiscontinuousTo-talizingAutomaticWeighingInstrument(Totalizinghopperweigher)] for dated reference documents, only the dated version is applicable to this regulation; for all undated references the latest version (including all amendments) is applicable to this regulation.
3 Terms and units of measurement
3.1 Term
JJF1001 "General Measurement Terms and Definitions" and JJF1181 "Weighing Instrument Measurement Terms and Definitions" defined and the following terms apply to this regulation.
3.1.1 automaticquantitativeloadingvehiclesystems According to the preset value sequence table formed by the vehicle preloading quantity and the vehicle sequence, a batch of bulk materials is Divide into several separated loads according to the preset value sequence table, determine the mass of each separated load in turn, and follow the predetermined procedure it is unloaded one by one, loaded into each carriage of a train or a fleet, and finally a weighing instrument for accumulating the loading amount.
3.1.2 indicatordevice After the signal of the weight sensor in the automatic quantitative loading system (hereinafter referred to as the loading system) is collected, the analog signal an electronic device that converts the signal into a digital signal and further processes the data to display the weighing result in mass units.
3.1.3 Totalization indicating device an indicator device for the total amount of bulk load that has been continuously weighed and discharged.
3.1.3.1 Primary totalization indicating device principaltotalizationindicatingdevice the cumulative indicating device of the total amount of bulk load that has been continuously weighed and discharged. The indicating device cannot be reset by the user is zero.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
How to Download JJG 1170-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
JJG 1170-2019