JJG 1169-2019Flue Gas Samplers (English PDF)
烟气采样器检定规程
This is a limited preview
Buy now to download the full PDF (11 pages)
Need quotation for your management?
Get a formal quotation for JJG 1169-2019 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2019
Implementation date
March 31, 2020
Scope
JJG 1169-2019 is the English-translated version of 烟气采样器检定规程.
JJG 1169-2019 is the Chinese standard "Flue Gas Samplers".
Found what you need?
Document preview — JJG 1169-2019
National Standard of the People's Republic of China
- ICS
- 17.020
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Overview (1)
- 3 Measurement performance requirements (1)
- 3.1 Flow indication error (1)
- 3.2 Flow repeatability (1)
- 3.3 Flow stability (1)
- 3.4 Timing error (1)
- 3.5 Indication error of temperature in front of the flowmeter (1)
- 3.6 Indication error of pressure in front of the flowmeter (1)
- 3.7 Atmospheric pressure indication error (1)
- 4 General technical requirements (1)
- 4.1 Appearance and power-on inspection (1)
- 4.2 Pumping capacity (2)
- 4.3 Airtightness (2)
- 4.4 Insulation resistance (2)
- 5 Control of measuring instruments (2)
- 5.1 Verification conditions (2)
- 5.2 Verification items (2)
- 5.3 Verification method (3)
- 5.4 Processing of verification results (6)
- 5.5 Verification period (6)
- Appendix A Verification Record Format of Flue Gas Sampler (7)
- Appendix B Format of the inner pages of the certificate of verification/notification of verification results (9)
1 Scope (1)
2 Overview (1)
3 Measurement performance requirements (1)
3.1 Flow indication error (1)
3.2 Flow repeatability (1)
3.3 Flow stability (1)
3.4 Timing error (1)
3.5 Indication error of temperature in front of the flowmeter (1)
3.6 Indication error of pressure in front of the flowmeter (1)
3.7 Atmospheric pressure indication error (1)
4 General technical requirements (1)
4.1 Appearance and power-on inspection (1)
4.2 Pumping capacity (2)
4.3 Airtightness (2)
4.4 Insulation resistance (2)
5 Control of measuring instruments (2)
5.1 Verification conditions (2)
5.2 Verification items (2)
5.3 Verification method (3)
5.4 Processing of verification results (6)
5.5 Verification period (6)
Appendix A Verification Record Format of Flue Gas Sampler (7)
Appendix B Format of the inner pages of the certificate of verification/notification of verification results (9)
Introduction
This regulation is based on JJF1002-2010 "Rules for Compiling National Measurement Verification Regulations", JJF1001-2011 "Tong Written in "Terms and Definitions of Measurement" and JJF1059.1-2012 "Measurement Uncertainty Evaluation and Representation".
This regulation refers to GB/T 16157 "Measurement of Particulate Matter in Exhaust from Fixed Pollution Sources and Sampling Method for Gaseous Pollutants" Law "and HJ/T 47" Technical Conditions of Flue Gas Sampler "related technical requirements and methods.
This regulation is issued for the first time.
Verification Regulation of Flue Gas Sampler
1 Scope
This regulation is applicable to the collection of gaseous pollutants in the exhaust of fixed pollution sources such as flues, chimneys and exhaust pipes and the sampling flow the first verification, follow-up verification and in-use inspection of the flue gas sampler whose volume is not more than 2.0L/min.
2 Overview
The flue gas sampler is used to collect harmful components (SO2, NOx, NH3, Hg, etc.) dedicated sampling instruments, mainly by flow measurement and control system, air pump, sampling tube Road and absorption device.
The working principle of the flue gas sampler (hereinafter referred to as the instrument) is to use the suction pump to pass the sample gas through the set flow rate.
The sampling pipeline is drawn into the absorption device, and the measurement control system according to the flow, pressure and temperature detected by various sensors Calculation of other parameters, control the suction pump to maintain the corresponding sampling flow, and complete the quantitative sampling according to the set sampling time Set requirements.
3 Measurement performance requirements
3.1 Flow indication error ± 5%.
3.2 Flow repeatability <=2%.
3.3 Flow stability
3.4 Timing error
3.5 Temperature indication error in front of the flowmeter ± 2 °C.
3.6 Indication error of pressure in front of the flowmeter ± 0.5kPa.
3.7 Atmospheric pressure indication error ± 0.5kPa.
4 General technical requirements
4.1 Appearance and power-on inspection
4.1.1 The instrument should have a complete structure, complete components and reliable connections, without external damage that would affect the normal operation of the instrument.
4.1.2 After the instrument is turned on, the buttons and switches should be adjusted flexibly, and the digital display should be clear and complete.
4.1.3 The nameplate of the instrument shall have the name, model, factory number, date of manufacture, measuring range, maximum allowable error,
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
How to Download JJG 1169-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
JJG 1169-2019
$285.00