JJG 1163-2019Multifunction Patient Monitoring Instruments (English PDF)
多参数监护仪
This is a limited preview
Buy now to download the full PDF (14 pages)
Need quotation for your management?
Get a formal quotation for JJG 1163-2019 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2019
Implementation date
March 31, 2020
Scope
JJG 1163-2019 is the English-translated version of 多参数监护仪.
JJG 1163-2019 is the Chinese standard "Multifunction Patient Monitoring Instruments".
Found what you need?
Document preview — JJG 1163-2019
National Standard of the People's Republic of China
- ICS
- 17.020
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Terms and units of measurement (1)
- 4 Overview (2)
- 5 Measurement performance requirements (2)
- 5.1 Voltage measurement error (2)
- 5.2 Scanning speed error (2)
- 5.3 Amplitude-frequency characteristics (3)
- 5.4 Heart rate indication error (3)
- 5.5 Static pressure measurement range (3)
- 5.6 Indication error of static pressure (3)
- 5.7 Repeatability of blood pressure indication (3)
- 5.8 Airtightness (3)
- 5.9 Pulse oximetry (3)
- 5.10 Pulse rate (3)
- 5.11 CO2 concentration at the end of call (3)
- 5.12 Respiration rate (3)
- 6 General technical requirements (3)
- 6.1 Appearance and signs (3)
- 6.2 The normal operation of the lead (3)
- 6.3 Alarm function (3)
- 6.4 Automatic pressure relief function (3)
- 7 Control of measuring instruments (4)
- 7.1 Verification conditions (4)
- 7.2 Measuring instruments and supporting equipment (4)
- 7.3 Verification items (5)
- 7.4 Verification method (5)
- 7.4.1 Appearance and work normality inspection (5)
- 7.4.2 Preparation before verification (5)
- 7.4.3 ECG (5)
- 7.4.4 Non-invasive blood pressure (7)
- 7.4.5 Pulse oximetry (8)
- 7.4.6 Exhaled carbon dioxide (9)
- 7.5 Processing of verification results (10)
- 7.6 Verification period (10)
- Appendix A. Original Records of Monitor Verification (11)
- Appendix B Format of the inner pages of the verification certificate and verification result notice (14)
1 Scope (1)
2 References (1)
3 Terms and units of measurement (1)
4 Overview (2)
5 Measurement performance requirements (2)
5.1 Voltage measurement error (2)
5.2 Scanning speed error (2)
5.3 Amplitude-frequency characteristics (3)
5.4 Heart rate indication error (3)
5.5 Static pressure measurement range (3)
5.6 Indication error of static pressure (3)
5.7 Repeatability of blood pressure indication (3)
5.8 Airtightness (3)
5.9 Pulse oximetry (3)
5.10 Pulse rate (3)
5.11 CO2 concentration at the end of call (3)
5.12 Respiration rate (3)
6 General technical requirements (3)
6.1 Appearance and signs (3)
6.2 The normal operation of the lead (3)
6.3 Alarm function (3)
6.4 Automatic pressure relief function (3)
7 Control of measuring instruments (4)
7.1 Verification conditions (4)
7.2 Measuring instruments and supporting equipment (4)
7.3 Verification items (5)
7.4 Verification method (5)
7.4.1 Appearance and work normality inspection (5)
7.4.2 Preparation before verification (5)
7.4.3 ECG (5)
7.4.4 Non-invasive blood pressure (7)
7.4.5 Pulse oximetry (8)
7.4.6 Exhaled carbon dioxide (9)
7.5 Processing of verification results (10)
7.6 Verification period (10)
Appendix A. Original Records of Monitor Verification (11)
Appendix B Format of the inner pages of the verification certificate and verification result notice (14)
Introduction
The preparation of this regulation is based on JJF1002-2010 "Rules for Compiling National Measurement Verification Regulations", JJF1001-2011 "General Measurement Terms and Definitions" and JJF1059.1-2012 "Measurement Uncertainty Evaluation and Expression" as the basis. this the procedure mainly refers to JJG 760-2003 "ECG Monitor" and JJG 692-2010 "Non-invasive automatic blood pressure measurement" meter".
This regulation is issued for the first time.
Verification Regulations of Multi-parameter Monitor
1 Scope
This regulation is applicable to the first verification, subsequent verification and in-use inspection of multi-parameter monitors.
This procedure covers the testing of four major parameters. electrocardiogram, non-invasive blood pressure, pulse oximetry, and end-carbon dioxide.
Any monitor measurement verification with all or part of the monitoring function shall be carried out in accordance with this regulation.
2 Reference documents this verification procedure refers to the following documents.
JJG 692 Noninvasive Automatic Blood Pressure Monitor JJG 760-2003 ECG monitor YY0601-2009 Special requirements for basic safety and main performance of medical electrical equipment respiratory gas monitor for dated references, only the dated versions are applicable to this Regulation; for those without dates the latest version (including all amendments) is applicable to this regulation.
3 Terms and units of measurement
3.1 Multifunction patient monitoringinstrument Instruments that can monitor and record various basic vital signs parameters of patients in real time, generally including ECG, Non-invasive blood pressure, pulse oximetry and end-tidal carbon dioxide etc. or more parameters.
3.2 ECG electrocardio in every cardiac cycle of the heart, the cardiac bioelectric potential caused by the successive excitation of the pacing point, atrium, and ventricle. heart Unit of electrical voltage. millivolt, symbol. mV; unit of heart rate. beats/min.
3.3 Sinus rhythm Heart rhythmic activity caused by electrical impulses from the sinus node of the heart. Sinus node is a heart made of special cells the small nodules on the viscera are the pacing points of the heart. The heart beats every time an impulse occurs in the sinoatrial node.
3.4 Amplitude-frequencycharacteristic the multi-parameter monitor measures the relationship between the voltage magnification and frequency of the human ECG signal. For measurement and display the electrocardiographic signal of the human body, the multi-parameter monitor generally has an amplifier circuit, and the amplifier circuit amplifies signals of different frequencies Capabilities may vary.
3.5 Blood pressure
The side pressure on the blood vessel wall when blood flows in the blood vessel. Blood pressure unit. kPa (or mm Hg), symbol no.. kPa (or mmHg), 1kPa = 7.5mmHg.
3.6 Static pressure
Pressure that does not change with time or changes slowly with time. Static pressure reflects the pressure after inflation and stabilization the internal pressure sensor of the multi-parameter monitor measures performance parameters.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.
How to Download JJG 1163-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
JJG 1163-2019
$315.00