JJG 1162-2019Clinical Electronic Thermometers (English PDF)
医用电子体温计
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for JJG 1162-2019 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
January 1, 2019
Implementation date
March 31, 2020
Scope
JJG 1162-2019 is the English-translated version of 医用电子体温计.
JJG 1162-2019 is the Chinese standard "Clinical Electronic Thermometers".
Found what you need?
Document preview — JJG 1162-2019
National Standard of the People's Republic of China
- ICS
- 17.200
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Terminology (1)
- 4 Overview (1)
- 5 Measurement performance requirements (2)
- 5.1 Indication error (2)
- 6 General technical requirements (2)
- 6.1 Appearance (2)
- 6.2 Temperature display range (2)
- 6.3 Temperature display resolution (2)
- 6.4 Prompt function (2)
- 6.5 Maximum hold function (3)
- 6.6 Memory function (3)
- 6.7 Automatic shutdown function (3)
- 7 Control of measuring instruments (3)
- 7.1 Verification conditions (3)
- 7.2 Verification items (4)
- 7.3 Verification method (4)
- 7.4 Processing of verification results (7)
- 7.5 Verification period (7)
- Appendix A Reference Format for the Original Record of Medical Electronic Thermometer Verification (8)
- Appendix B. Medical Electronic Thermometer Verification Certificate (Inner Page) Format (13)
- Appendix C. Notification Form (Inner Page) of the Verification Results of Medical Electronic Thermometer (14)
- Appendix D Examples of Uncertainty Evaluation of Indication Errors of Medical Electronic Thermometers (1) (15)
- Appendix E Examples of Uncertainty Evaluation of the Indication Errors of Medical Electronic Thermometers (2) (18)
- Appendix F. Reference function table of standard platinum resistance thermometers at (30 ~ 45) °C as specified by the 1990 international temperature scale
1 Scope (1)
2 References (1)
3 Terminology (1)
4 Overview (1)
5 Measurement performance requirements (2)
5.1 Indication error (2)
6 General technical requirements (2)
6.1 Appearance (2)
6.2 Temperature display range (2)
6.3 Temperature display resolution (2)
6.4 Prompt function (2)
6.5 Maximum hold function (3)
6.6 Memory function (3)
6.7 Automatic shutdown function (3)
7 Control of measuring instruments (3)
7.1 Verification conditions (3)
7.2 Verification items (4)
7.3 Verification method (4)
7.4 Processing of verification results (7)
7.5 Verification period (7)
Appendix A Reference Format for the Original Record of Medical Electronic Thermometer Verification (8)
Appendix B. Medical Electronic Thermometer Verification Certificate (Inner Page) Format (13)
Appendix C. Notification Form (Inner Page) of the Verification Results of Medical Electronic Thermometer (14)
Appendix D Examples of Uncertainty Evaluation of Indication Errors of Medical Electronic Thermometers (1) (15)
Appendix E Examples of Uncertainty Evaluation of the Indication Errors of Medical Electronic Thermometers (2) (18)
Appendix F. Reference function table of standard platinum resistance thermometers at (30 ~ 45) °C as specified by the 1990 international temperature scale
(twenty one)
Introduction
This regulation is based on GB/T 21416-2008 "Medical Electronic Thermometer" and OIMLR115 (1995 version) Medical electronic thermometer with maximum value display device (Clinicalelectricalthermometerswithmaximum device), the scope, terminology and appearance requirements of OIMLR115 are modified, and a standard instrument is used for verification the temperature field distribution requirements of the device and thermostat are consistent with OIMLR115, and refer to ASTME1112-00 (2018) "Standard Specification for Electronic Intermittent Measurement of Patient's Body Temperature" ThermometerforIntermittentDeterminationofPatientTemperature) and JIST1140-2014 "Electronic thermometer" and other standards were formulated.
This regulation is issued for the first time.
Verification Regulation of Medical Electronic Thermometer
1 Scope
This regulation is suitable for intermittent measurement of body temperature of different parts of the human armpit, mouth, rectum, etc., and has the maximum value the first verification, follow-up verification and in-use inspection of the contact-type medical electronic thermometer that maintains function.
2 Reference documents this regulation refers to the following documents.
JJG 130-2011 working glass liquid thermometer JJG 161-2010 Standard mercury thermometer for dated reference documents, only the dated version applies to this regulation; for non-date quoted documents the latest version (including all amendments) is applicable to this regulation.
3 Terminology
3.1 Medical electronic thermometer clinicalelectronicthermometer Thermometer that uses sensors and circuits for clinical measurement of human body temperature.
3.2 Integrated medical electronic thermometer compactclinicalelectronicthermometer the temperature probe and the circuit are inseparable, and the two are closely connected into a medical electronic thermometer.
3.3 Split medical electronic thermometer assembledclinicalelectronicthermometer the temperature probe and the circuit can be separated, and the two are connected by a medical electronic thermometer.
3.4 Temperature probe it consists of a temperature sensor and a temperature-sensitive jacket, etc. It is used to position the sensor at a specified position for temperature measurement.
4 Overview
Medical electronic thermometer (hereinafter referred to as electronic thermometer) is mainly composed of temperature sensor, special chip, digital display the display and other circuits and components are used to measure the temperature of the human body. According to the structure, it can be divided into one type and two types. its the working principle is. during measurement, the temperature sensor senses the measured temperature and outputs an electrical signal, and the electrical signal is input to the dedicated core After processing, the maximum value of the measured temperature during the measurement is displayed on the digital display, and the display maximum value is kept to Automatic shutdown.
The typical structure of the integrated electronic thermometer is shown in Figure 1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
How to Download JJG 1162-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
JJG 1162-2019
$420.00