Scope

JJG 1161-2019 is the English-translated version of 矿用硫化氢气体检测仪检定规程.

JJG 1161-2019 is the Chinese standard "Hydrogen Sulfide Gas Detectors for Mining".

Found what you need?

Document preview — JJG 1161-2019

National Standard of the People's Republic of China

ICS
17.020

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 Overview (1)
  • 3 Measurement performance requirements (1)
  • 3.1 Indication error (1)
  • 3.2 Repeatability (1)
  • 3.3 Response time (1)
  • 3.4 Drift (1)
  • 3.5 Signal transmission error (1)
  • 4 General technical requirements (1)
  • 4.1 Appearance and structure (1)
  • 4.2 Marks and logos (2)
  • 4.3 Power-on inspection (2)
  • 4.4 Alarm function and alarm action value check (2)
  • 4.5 Insulation resistance (2)
  • 5 Control of measuring instruments (2)
  • 5.1 Verification conditions (2)
  • 5.2 Verification items (3)
  • 5.3 Verification method (4)
  • 5.4 Processing of verification results (7)
  • 5.5 Verification period (7)
  • Appendix A Technical Requirements for Simulation Circuit (8)
  • Appendix B. Mine Hydrogen Sulfide Gas Detector Measurement Verification Original Record Form (9)
  • Appendix C Format of the inner pages of the verification certificate/certification result notice (11)

1 Scope (1)

2 Overview (1)

3 Measurement performance requirements (1)

3.1 Indication error (1)

3.2 Repeatability (1)

3.3 Response time (1)

3.4 Drift (1)

3.5 Signal transmission error (1)

4 General technical requirements (1)

4.1 Appearance and structure (1)

4.2 Marks and logos (2)

4.3 Power-on inspection (2)

4.4 Alarm function and alarm action value check (2)

4.5 Insulation resistance (2)

5 Control of measuring instruments (2)

5.1 Verification conditions (2)

5.2 Verification items (3)

5.3 Verification method (4)

5.4 Processing of verification results (7)

5.5 Verification period (7)

Appendix A Technical Requirements for Simulation Circuit (8)

Appendix B. Mine Hydrogen Sulfide Gas Detector Measurement Verification Original Record Form (9)

Appendix C Format of the inner pages of the verification certificate/certification result notice (11)

Introduction

This regulation is written in accordance with the requirements and format of JJF1002-2010 "Rules for the Compilation of National Metrology Verification Regulations".

The main technical indicators of this regulation refer to MT1084-2008 "Hydrogen Sulfide Detection Alarm for Coal Mine".

This regulation is issued for the first time.

Verification Regulation of Mine Hydrogen Sulfide Gas Detector

1 Scope

This regulation is applicable to the first verification, subsequent verification and use of the hydrogen sulfide gas detector in the mine operating environment an examination.

2 Overview

The hydrogen sulfide gas detector (hereinafter referred to as the detector) is mainly composed of the detection unit (gas chamber, sensitive components, etc.) Signal processing transmission unit, display unit, etc., through the sensitive element to convert the concentration of hydrogen sulfide gas into an electrical signal, and then After the signal processing and transmission unit, the display unit finally displays the hydrogen sulfide concentration value.

The detector is divided into diffusion type and suction type according to the sampling method, and is divided into portable and fixed type according to the use method. Fixed the detector has an electric signal output function.

3 Measurement performance requirements

3.1 Indication error the indication error of the detector should meet the requirements of Table 1.

Table 1 Indication error of detector

Measuring range x/(µmol/mol) Maximum allowable error in-use inspection for the first verification and subsequent verification 0<=x4 General technical requirements

4.1 Appearance and structure

4.1.1 The detector should not have any appearance damage that affects its normal operation. The surface of the newly manufactured detector should be smooth and smooth, the paint color coating is uniform, without peeling and rusting, and the joints of all parts should be smooth.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

How to Download JJG 1161-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 1161-2019

$270.00