Scope

JJG 1158.2-2018 (Rail Thermometers--Part 2: Digital Rail Thermometers) is available as an English-translated PDF.

JJG 1158.2-2018 — 2 Overview 1 3 Metrology performance requirements 1 3.1 indication error 1 3.2 Indication variation 1 3.3 Working voltage 1 3.4 Adsorption force 1 3.5 Resolution 1 4 General technical requirements 1 4.1 Appearance 1 4.2 Identification 1 4.3 Digital display 1 5 measuring instrument control 1 5.1 Verification conditions 2 5.2 Verification project 2 5.3 Verification method 2 5.4 Processing of verification results 4

Found what you need?

Document preview — JJG 1158.2-2018

National Standard of the People's Republic of China

Classification
A 54

Issued by: State Administration for Market Regulation

Contents

  • Introduction
  • 1 Scope
  • 2 Overview
  • 3 Metrology performance requirements
  • 3.1 Indication error
  • 3.2 Indication variation
  • 3.3 Working voltage
  • 3.4 Adsorption force
  • 3.5 Resolution
  • 4 General technical requirements
  • 4.1 Appearance
  • 4.2 Identification
  • 4.3 Digital display
  • 5 Measuring instrument control
  • 5.1 Verification conditions
  • 5.2 Verification project
  • 5.3 Verification method
  • 5.4 Processing of verification results
  • 5.5 Verification cycle
  • Appendix A Digital Rail Thermometer Verification Record Format
  • Appendix B Verification certificate and verification result notice page format

1 Scope 1

2 Overview 1

3 Metrology performance requirements 1 3.1 indication error 1

3.2 Indication variation 1

3.3 Working voltage 1

3.4 Adsorption force 1

3.5 Resolution 1

4 General technical requirements 1

4.1 Appearance 1

4.2 Identification 1

4.3 Digital display 1 5 measuring instrument control 1

5.1 Verification conditions 2

5.2 Verification project 2

5.3 Verification method 2

5.4 Processing of verification results 4

5.5 Verification cycle 4

Appendix A Digital Rail Thermometer Verification Record Format 5

Appendix B Verification certificate and verification result notice page format 6

Introduction

JJG 1158 "Steel Thermometer" consists of the following two parts.

--- Part 1. Bimetal rail thermometer;

--- Part 2. Digital rail thermometer.

In the use of this procedure for the rail thermometer temperature test, the corresponding procedure should be selected according to the type of rail thermometer section.

This regulation is based on TG/GW115-2012 "High-speed railway ballastless track maintenance rules" (trial) Made.

This procedure is the first release.

Rail thermometer test procedure Part 2. Digital rail thermometer

1 Scope

This procedure applies to the first verification, subsequent verification and in-use inspection of digital rail thermometers.

2 Overview

The digital rail thermometer (hereinafter referred to as the rail thermometer) uses a temperature sensor as a temperature sensing element and is displayed by a secondary meter.

A thermometer that shows the temperature of the rail. The gauge of the gauge is (-40~70) °C.

3 Metrological performance requirements 3.1 indication error the maximum allowable error of the gauge is ±1.0 °C.

3.2 Variation of indication value the indication value of the gauge should be no more than 2 words.

3.3 Working voltage

The operating voltage of the rail thermometer is the voltage specified in the instruction manual. When the battery is low, the display should have a low battery.

Instructions. The indication error of the gauge should not exceed ±1.0 °C when there is a low battery indication.

3.4 Adsorption force the adsorption force of the rail thermometer should be no less than 1.96N at the first inspection, and the subsequent inspection should be no less than 1.47N.

3.5 resolution

The gauge should show a resolution of no more than 0.1 °C.

4 General technical requirements

4.1 Appearance

The shape of the gauge should be intact, and the digital display panel should not have defects that hinder correct reading.

The layer should not have rust and plating peeling off. The temperature-sensitive working surface should not have local convex and concave phenomenon, and there should be no oxide film or grease stain.

And substances such as dust that affect the accuracy of temperature measurement. The connection between the rail thermometer sensor and the secondary instrument should be reliable.

A rail thermometer in use allows for defects that do not affect accuracy.

4.2 Identification

The gauge should be marked with the name of the manufacturer or the factory standard, the model of the gauge, the factory number, and the temperature unit (°C).

4.3 Digital display

The temperature display of the rail thermometer should be continuous without stacking, uniform brightness, and there should be no phenomenon such as no light, lack of strokes, etc., decimal point the settings are correct.

5 measuring instrument control Metering device controls include initial verification, subsequent verification, and in-use inspection.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

How to Download JJG 1158.2-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 1158.2-2018

$155.00