JJG 1148-2022AC Charge Spots for Electric Vehicles(for Trial Implementation) (English PDF)

Preview PDF

Also coversJJG1148-2022

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for JJG 1148-2022 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

June 28, 2022

Implementation date

December 28, 2022

Scope

JJG 1148-2022 (AC Charge Spots for Electric Vehicles(for Trial Implementation)) is available as an English-translated PDF.

JJG 1148-2022 is the Chinese standard "AC Charge Spots for Electric Vehicles(for Trial Implementation)". Its scope clause reads: This Regulation applies to the first verification, follow-up verification and in-use inspection for AC charge spots for electric vehicles.

The verification of AC charge spots for electric vehicles based on the statistical sampling method can be carried out in accordance with this Regulation. Its clauses include terms; overview; measuring instrument control.

It was issued by the State Administration for Market Regulation on 2022-06-28 and took effect on 2022-12-28.

Found what you need?

Document preview — JJG 1148-2022

National Standard of the People's Republic of China

Issued by: State Administration for Market Regulation

Contents

  • Introduction...5
  • 1 Scope...6
  • 2 Normative references...6
  • 3 Terms...6
  • 4 Overview...7
  • 5 Metering performance requirements...8
  • 5.1 Operate error...8
  • 5.2 Clock time error...9
  • 6 General technical requirements...9
  • 6.1 Identification...9
  • 6.2 Testing interface...10
  • 6.3 Constant...10
  • 6.4 Minimum power variable...10
  • 6.5 Display of charging energy...10
  • 7 Measuring instrument control...10
  • 7.1 First verification, follow-up verification and in-use inspection...10
  • 7.2 Verification conditions...10
  • 7.3 Verification items and verification methods...11
  • 7.4 Processing of verification results...16
  • 7.5 Verification period...16
  • Annex A Format for original record of verification...17

1 Scope

This Regulation applies to the first verification, follow-up verification and in-use inspection for AC charge spots for electric vehicles.

The verification of AC charge spots for electric vehicles based on the statistical sampling method can be carried out in accordance with this Regulation.

2 Normative references

This Regulation refers to the following documents:

JJG 596, Verification Regulation of Electrical Meters for Measuring Alternating- current Electrical Energy

JJG 597, Verification Regulation of Verification Equipment for AC Electrical Energy

Meters

JJF 1139, Principle and method for determination verification period of measuring instruments

For the dated documents, only the versions with the dates indicated are applicable to this Regulation; for the undated documents, only the latest version (including all the amendments) is applicable to this Regulation.

3 Terms

The following terms and definitions apply to this document.

3.1 AC charge spot

A special device that uses conduction method to provide AC power for electric vehicles with on-board charging equipment, it has the functions of measuring and storing AC power and providing results to users.

3.2 connection point

A connection point that the AC charge spot is connected to electric vehicle.

NOTE: If the output cable is a fixed part of the AC charge spot, this point is defined as the connector at the end of the cable. Otherwise, the connection point is defined as the cable insertion point of the

AC charge spot.

3.3 real load test method

A method of verification using the actual operating load.

3.4 virtual load test method

A method that uses the virtual load provided by the AC charge spot verification device for verification.

3.5 operate error

AC power measurement error of AC charge spot under working conditions.

3.6 test output

A device that provides pulses corresponding to the AC power measured by the AC charge spot.

3.7 constant

A numerical value representing the relationship between the electric energy recorded by the AC charge spot and the corresponding test output value.

3.8 nominal voltage

The output voltage of the AC charge spot specified by the manufacturer during normal operation.

4 Overview

An AC charge spot (hereinafter referred to as charge spot) is a metering device that provides AC power for electric vehicles. It is mainly composed of spot body, connecting device for conductive charging, control unit, metering module, display interface or data transmission interface and other parts. The schematic diagram of the charge spot is shown in Figure 1.

The charge spot provides the required AC power for the electric vehicle through the control unit. The electric energy is transmitted to the electric vehicle through the connection device for conductive charging to meet the charging demand. The metering module completes the metering of electric energy, and outputs the measured quantity to the display interface or data transmission interface.

2 For charge spots installed before January 1, 2023, if the accuracy level is not marked, it will be implemented as level 2.

6.2 Testing interface

The technical indicators of the test output and communication interface of the charge spot for verification shall meet the requirements of relevant standards.

6.3 Constant

The charge spot shall have a pulse output corresponding to the measured AC power, which shall be consistent with the constant marked on the nameplate.

6.4 Minimum power variable

The minimum electric energy variable shall be 0.001kW·h.

6.5 Display of charging energy

The charge spot shall be able to display the charging energy. The number of digits displayed for electric energy shall not be less than 6 (including at least 3 decimal places).

For charge spots with time-of-use billing function, the clock time display resolution is not greater than 1s.

7 Measuring instrument control

7.1 First verification, follow-up verification and in-use inspection

The first verification is a verification of charge spots that have not been verified. The follow-up verification is any verification after the first verification. Repaired charge spots must be verified as the first verification. In-use inspection is an inspection to find out whether the verification mark or verification certificate of the charge spot is valid, and whether the verified charge spot has been significantly modified.

7.2 Verification conditions

7.2.1 Ambient conditions for verification

When verifying the charge spot, the following conditions shall be met:

- Verification conditions and their deviations do not exceed those specified in Table

3.

- There shall be no appreciable shock load. The seal of the charge spot is complete.

the electric energy values measured simultaneously by the verification device and the charge spot under verification, so as to determine the operate error of the charge spot under verification.

Method I:

When both the charge spot calibrator and the charge spot under verification are working continuously, use the pulse output by the charge spot under verification to control the counting of the calibrator to determine the operate error of the charge spot under verification. When using this method, apply method II to check whether the charge spot constant is correct.

The operate error gamma of the verified charge spot is calculated according to (1).

Where, m - the measured pulse number;

m0 - the calculated and determined pulse number, calculated according to formula (2).

Where,

N - the number of pulses of the verified charge spot;

C0 - the constant of calibrator, imp/ (kW·h);

CL - the constant of the verified charge spot, imp/ (kW·h).

NOTE: Select the appropriate pulse number N of the charge spot under verification, so that the quantification error of the calculation and determination of the number of pulses is not greater than 1/10 of the grade index of the charge spot under verification.

Method II:

When both the charge spot calibrator and the charge spot under verification are working continuously, use the output electric energy indication value of the verified charge spot and the measured electric energy value of the charge spot calibrator to determine the operate error of the verified charge spot.

The operate error gamma of the verified charge spot is calculated according to (3):

Where,

E' - the difference between the indicated value of the electric energy when the charge spot under verification stops charging and when charging starts, kW·h;

E - the energy value measured by the calibrator, kW·h;

gamma0 - the established systematic error of the verification device; when no correction is required, gamma0=0.

The calibrator shall run synchronously with the charge spot under verification. The ratio (%) of the electric energy value represented by the last word (or the minimum scale value) of the display of the charge spot under verification to the accumulated E' shall not be greater than 1/5 of the grade index of the charge spot under verification.

During the verification process, record the error measurement data at least twice.

Take the average value to calculate the operate error.

2) Virtual load test method

Use a verification device. Compare the electric energy values measured simultaneously by the verification device and the charge spot under verification, so as to determine the error of the charge spot under verification. When using the virtual load test method, the influence of the connection position on the test results shall be considered.

The standard table method is used to test the charge spot according to the provisions of 1).

Use watt-second method to verify the charge spot. Use a calibrator to measure the set constant power or use a standard power source to determine the power. The quantification error of the number of digits displayed by the calibrator or power source shall not be greater than 1/10 of the grade index of the charge spot under verification. At the same time, use a standard timer to measure the time required for the charge spot to output several pulses at a constant power. The actual electric energy is obtained by the product of this time and the constant power. Compare with the electric energy measured by the charge spot to determine the operate error of the charge spot.

The operate error is calculated according to formula (4):

7.4 Processing of verification results

7.4.1 Processing of verification results

7.4.1.1 Judging all data shall be subject to the rounded data.

7.4.1.2 The rounding interval of operate error is 1/10 of the accuracy level of the charge spot.

7.4.1.3 The rounding interval of the clock time error is 1s.

7.4.2 Rounding off method for measurement data

7.4.2.1 Rounding off method when the rounding off interval is 1: For the number 1 of the reserved digit on the right side of the reserved digit, if it is greater than 0.5, add 1 to the reserved digit. If it is less than 0.5, the reserved bit remains unchanged. If it is equal to 0.5, the reserved bit remains unchanged when it is an even number. Add 1 when the reserved bit is odd.

NOTE: "Reserved bit" refers to the number corresponding to the rounding interval. This value is called a "reserved bit".

7.4.2.2 Rounding method when the rounding interval is n (n!=1): Divide the measured data by n. Then round off according to the method of 7.4.2.1. After rounding, multiply by n, which is the final rounding result.

7.4.3 If all items meet the requirements, it is judged as qualified, otherwise it is judged as unqualified. Charge spots that pass the verification will be issued a verification certificate (see Annexes B and C for the format of the verification certificate) and a verification mark.

7.4.4 A certified charge spot must be sealed at the position of the electric energy meter or metering module used inside it.

7.4.5 A test result notification will be issued to the unqualified charge spot (see Annexes

B and C for the format). Cancel the original certification seal or certification mark.

7.5 Verification period

The verification period of the charge spot is generally not more than 3 years. The verification period can be adjusted appropriately according to JJF 1139 and the regulations of the metrology administrative department. For charge spots that have metering performance online monitoring conditions or anti-cheating functions, and have implemented data transmission, the verification period can be appropriately extended upon approval of the metering administrative department.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

Normative references

JJG 596 · JJG 597 · JJF 1139

How to Download JJG 1148-2022

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 1148-2022

$235.00