Valid

JJG 1145-2017Medical X-ray Radiation Sources for Mammographic Equipment (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (12 pages)

Need quotation for your management?

Get a formal quotation for JJG 1145-2017 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

November 20, 2017

Implementation date

February 20, 2018

Scope

JJG 1145-2017 (Medical X-ray Radiation Sources for Mammographic Equipment) is available as an English-translated PDF.

JJG 1145-2017 — This standard applies to the first verification, follow-up verification and in-use inspection of medical mammography X-ray sources. It includes medical digital mammographic X-ray sources and medical non-digital mammographic X-ray sources.

Found what you need?

Document preview — JJG 1145-2017

National Standard of the People's Republic of China

ICS
17.240
Classification
A 58

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 References (1)
  • 3 Terms and units of measure (1)
  • 3.1 Terms (1)
  • 3.2 Units of measurement (1)
  • 4 Overview (1)
  • 5 Metrological performance requirements (2)
  • 5.1 Average breast gland dose (2)
  • 5.2 Resolution (2)
  • 5.3 Radiation output (2)
  • 5.4 X-ray tube voltage (2)
  • 6 General technical requirements (2)
  • 7 Measuring Instruments Control (2)
  • 7.1 Verification conditions (2)
  • 7.2 Verification Projects (3)
  • 7.3 Verification Methods (3)
  • 7.4 Processing of verification results (7)
  • 7.5 Certification Period (8)
  • Appendix A Verification Certificate and Notification of Verification Results (Inner Page) Recommended Format (9)
  • Appendix B Testimonial Original Record Recommended Format (10)
  • Appendix C Various Breast X-Ray Targets/Filters (11)
  • Appendix D Dose Performance Modal Technical Requirements (12)
  • Appendix E Resolving Modal Technical Requirements (13)

1 Scope (1)

2 References (1)

3 Terms and units of measure (1)

3.1 Terms (1)

3.2 Units of measurement (1)

4 Overview (1)

5 Metrological performance requirements (2)

5.1 Average breast gland dose (2)

5.2 Resolution (2)

5.3 Radiation output (2)

5.4 X-ray tube voltage (2)

6 General technical requirements (2)

7 Measuring Instruments Control (2)

7.1 Verification conditions (2)

7.2 Verification Projects (3)

7.3 Verification Methods (3)

7.4 Processing of verification results (7)

7.5 Certification Period (8)

Appendix A Verification Certificate and Notification of Verification Results (Inner Page) Recommended Format (9)

Appendix B Testimonial Original Record Recommended Format (10)

Appendix C Various Breast X-Ray Targets/Filters (11)

Appendix D Dose Performance Modal Technical Requirements (12)

Appendix E Resolving Modal Technical Requirements (13)

Introduction

This regulation was prepared in accordance with the requirements of JJF1002-2010 "Rules for the preparation of national metrological verification regulations." JJF1001-

2011 Common Measurement Terms and Definitions and JJF1059.1-2012 Measurement Uncertainty Evaluation and Expression to support the establishment of this regulation and the preparation of the basis.

This regulation is issued for the first time.

Medical breast X-ray radiation source verification procedures

1 Scope

This procedure is applicable to the first verification, subsequent verification and in-use inspection of medical breast X-ray radiation sources. Its package Including medical digital breast X-ray sources and medical non-digital mammography sources. Does not apply to medical breast numbers Font layer synthetic photography X-ray radiation source.

2 references

This procedure refers to the following documents.

JJF1001 Universal Measurement Terms and Definitions JJF1035 Ionizing Radiation Measurement Terms and Definitions WS522-2017 Mammography Digital Radiography System Quality Control Inspection Specification IEC 61223-3-2:2007 Evaluation and routine testing of medical imaging departments - Part 3-2. Acceptance tests Mammography X-ray imaging performance (Evaluation and routine testing in medical imaging Departments Part 3-2.Acceptancetests-ImagingperformanceofmammographicX-ray Equipment Health Quality Assurance Guide (Europeanguidelinesforqualityassuranceinbreastcancerscreeningand Diagnosis) IAEAHumanHealthReportsNo.4-2011 Implementation of International Standards for Diagnostic Radiation Dosimetry (TRS)

457). Evaluation of Measurement Results[Implementation of the International Code of Practice on Dosimetryin DiagnosticRadiology(TRS457).ReviewofTestResults] for dated references, only the dated version applies to this procedure; any undated references the latest version (including all amendments) is applicable to this procedure.

3 Terms and units of measure

3.1 Terms

The terms and definitions defined by JJF1001, JJF1035, and the following apply to this procedure.

3.1.1 Mammary gland average dose averagelandlanddose, AGD Subjects in mammography were subjected to uniform compression of the breast's glandular tissue (excluding skin and fat) the average absorbed dose of tissues).

3.2 Units of measurement Absorbed dose, the unit name is Ge, and the unit symbol is Gy.

4 Overview

Medical breast X-ray source is mainly composed of X-ray source assembly, high voltage generator, imaging device, image processing

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.

How to Download JJG 1145-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
12 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 1145-2017

$235.00