JJG 1123-2016Electronic Instruments for Front-end Loader (English PDF)
This is a limited preview
Buy now to download the full PDF (12 pages)
Need quotation for your management?
Get a formal quotation for JJG 1123-2016 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
March 3, 2016
Implementation date
June 3, 2016
Scope
JJG 1123-2016 (Electronic Instruments for Front-end Loader) is available as an English-translated PDF.
JJG 1123-2016 — This standard is applicable to the first verification and follow-up verification of the electronic balance of the loader (hereinafter referred to as "loading scale"), which automatically weighs the single load and has the grade of accuracy Y (b).
Found what you need?
Document preview — JJG 1123-2016
National Standard of the People's Republic of China
- ICS
- 17.1
- Classification
- A 53
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Terms and units of measurement (1)
- 3.1 Terms (1)
- 3.2 Units of measurement (2)
- 4 Overview (2)
- 5 Measurement performance requirements (2)
- 5.1 Test scale value (2)
- 5.2 Relationship between accuracy level and test scale value, test indexing degree and minimum weighing capacity (2)
- 5.3 Minimum cumulative load value (sumMin) (2)
- 5.4 Maximum allowable error for single weighing (3)
- 5.5 Maximum allowable error of cumulative weighing (3)
- 5.6 Partial load (3)
- 5.7 Tilt (3)
- 5.8 Alternate operation speed (3)
- 6 General technical requirements (3)
- 6.1 Safety of measurement (3)
- 6.2 Tilt limit device (3)
- 6.3 Consistency of the pointing device with the printing device (3)
- 6.4 Metrological markings and metrological instruments (4)
- 7 Metering device control (4)
- 7.1 Test conditions (4)
- 7.2 Verification Project (5)
- 7.3 Inspection of general technical requirements (5)
- 7.4 Measurement performance test (5)
- 7.5 Processing of test results (7)
- 7.6 Verification cycle (7)
- Appendix A Verification Record Format (Recommended) (8)
- Appendix B Verification Certificate Page Format (Recommended) (10)
- Appendix C Results of Notification (Page 7) (12)
1 Scope (1)
2 References (1)
3 Terms and units of measurement (1)
3.1 Terms (1)
3.2 Units of measurement (2)
4 Overview (2)
5 Measurement performance requirements (2)
5.1 Test scale value (2)
5.2 Relationship between accuracy level and test scale value, test indexing degree and minimum weighing capacity (2)
5.3 Minimum cumulative load value (sumMin) (2)
5.4 Maximum allowable error for single weighing (3)
5.5 Maximum allowable error of cumulative weighing (3)
5.6 Partial load (3)
5.7 Tilt (3)
5.8 Alternate operation speed (3)
6 General technical requirements (3)
6.1 Safety of measurement (3)
6.2 Tilt limit device (3)
6.3 Consistency of the pointing device with the printing device (3)
6.4 Metrological markings and metrological instruments (4)
7 Metering device control (4)
7.1 Test conditions (4)
7.2 Verification Project (5)
7.3 Inspection of general technical requirements (5)
7.4 Measurement performance test (5)
7.5 Processing of test results (7)
7.6 Verification cycle (7)
Appendix A Verification Record Format (Recommended) (8)
Appendix B Verification Certificate Page Format (Recommended) (10)
Appendix C Results of Notification (Page 7) (12)
Introduction
This procedure mainly refers to the international legal system OIMLR51 "automatic sub-scale instrument (2006 edition)" [Automaticcatchweighinginstruments (2006E)] International Recommended Y-Class Vehicle Combination Automatic Weighing of the technical requirements and verification methods, in the preparation of the implementation of the format JJF1002-2010 "national measurement procedures Write rules ".
This procedure is based on the metering characteristics of the loader electronic scale used on the front wheel loader, Requirements, general technical requirements, list of test items, verification methods, processing of test results and verification period and so on Has been provided.
This procedure gives the Appendix A verification record format, Appendix B verification certificate page format and Appendix C test results Notice page format.
This order is the first release.
Test procedure for electronic scale of loader
1 Scope
This procedure is applicable to loader electronics that automatically weighs a bulk load and has an accuracy rating of Y (b) Scale (hereinafter referred to as "load scale") the first test, follow-up test.
2 reference file
This procedure refers to the following documents.
JQF1181 Weighing Terms and Definitions OIMLR51..2006 (E) Automatic grading instrument (Automaticcatchweighinginstruments) for dated references, only the dated edition applies to this rule; references that are not dated , The latest version (including all amendments) applies to this procedure.
3 terms and units of measurement 3.1 terminology the terminology used in this procedure is to use JJF1181 for the convenience of use and for ease of reference, with the addition of the following terms.
Automatic dispatching machine automaticallycatchweighinginstrument an automatic weighing of a preloaded separation load or a single load of a bulk.
3.1.2 Vehicle combination Weighing vehicleincorporatedinstrument is a type of automatic grading instrument, the vehicle and the weighing part of the common use of the same components (lever, connector Wait).
Combined with the loader, for the bucket in the shovel material and continuous lifting process of weighing an automatic Weighing.
3.1.4 load load
Due to the role of gravity, the loader of the instrument to force the load of objects, and sometimes directly refers to their force.
The load referred to in this procedure may be a weight or other dimensionally stable item.
3.1.5 single weighing Load the scale every time the process of weighing the load automatically.
3.1.6 cumulative weighing totalweighing the load gauge automatically counts the total amount of load.
3.1.7 maximum lifting speed maximumhoistingspeed the maximum speed that can be used to perform normal operation.
3.1.8 minimum cumulative load minimumtotalizedload the amount expressed in mass units, the cumulative value of the load scale is less than the value of the cumulative value may exceed the specified phase on the error.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
How to Download JJG 1123-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
Secure payment via Stripe
Payments accepted
JJG 1123-2016