JJG 1115-2015 (Apparent Charge Calibrator for Partial Discharge Measurements) is available as an English-translated PDF.

JJG 1115-2015 — This Standard applies to partial discharge calibrator initial verification, use and subsequent verification check.

Found what you need?

Document preview — JJG 1115-2015

National Standard of the People's Republic of China

ICS
17.220
Classification
A 55

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 Overview (1)
  • 3 Metering performance requirements (1)
  • 3.1 Calibrator Level (1)
  • 3.2 Calibration of the output pulse (1)
  • 3.3 Step voltage waveform generator output voltage step (2)
  • 3.4 Of capacitance of the capacitor (2)
  • 3.5 Calibrator resistance (2)
  • 4 General Requirements (2)
  • 4.1 Appearance and logo (2)
  • 4.2 Other requirements (2)
  • 5 Control of measuring instruments (3)
  • 5.1 Test conditions (3)
  • 5.2 Test items and test methods (4)
  • 5.3 Verification Results Processing (7)
  • 5.4 Test cycle (7)
  • Appendix A Pulse waveform parameter definitions and test methods (8)

1 Scope (1)

2 Overview (1)

3 Metering performance requirements (1)

3.1 Calibrator Level (1)

3.2 Calibration of the output pulse (1)

3.3 Step voltage waveform generator output voltage step (2)

3.4 of capacitance of the capacitor (2)

3.5 Calibrator resistance (2)

4 General Requirements (2)

4.1 Appearance and logo (2)

4.2 Other requirements (2)

5 Control of measuring instruments (3)

5.1 Test conditions (3)

5.2 Test items and test methods (4)

5.3 Verification Results Processing (7)

5.4 Test cycle (7)

Appendix A pulse waveform parameter definitions and test methods (8)

B step voltage waveform parameter definitions and test methods Appendix (10) Appendix C test original record format (12) Appendix D calibration certificate/test results in the notice page format (14)

Introduction

This procedure based on the national measurement specifications JJF1002-2010 "national verification procedures to write rules" prepared by.

This procedure uses a reference to the drafting of the national standard GB/T 7354-2003/IEC 60270:2000 "partial discharge Measuring "the relevant provisions.

This procedure was first formulated.

Partial discharge calibrator verification procedures

1 Scope

The order applies to partial discharge calibrator initial verification, use and subsequent verification check.

2 Overview

Partial Discharge Calibrator (hereinafter referred to as "the Calibrator") is a current pulse generator, a current pulse generator Calibration pulse generating means to provide duplicate charges, for calibrating partial discharge measurement system. Calibration is usually by the step voltage generator and capacitor division two parts. Step voltage generator through a capacitor in series with indexing Injects standard amount of electric charge to the partial discharge detection test circuit.

3 metering performance requirements

3.1 Calibrator Level (See Table 1) calibrator be classified according to performance measurement calibration output charge amount. Press the range allowed for school Aligner conduct classification.

Table 1 calibrator output charge amount requirements

Accuracy class maximum permissible error level 2 ± 2% (when measured value is greater than or equal 50pC time) ± 1pC (when the measured value is less than 50pC) Grade 5 ± 5% (when measured value is greater than or equal 20pC time) ± 1pC (when the measured value is less than 20pC time) ± 10% (when measured value is greater than or equal 20pC time) ± 2pC (when the measured value is less than 20pC time) 3.2 calibration output pulse Calibration of the output pulse is the voltage pulse calibrator external load resistor.

3.2.1 pulse waveform Calibration of the output pulse waveform distortion amount and time parameters (as defined in Appendix A) shall meet the provisions of Table 2.

Table 2 calibration of the output pulse waveform parameter index requirements

Wide at the bottom level of the amount of distortion th1 time interval T2 Level 2 100µs <=20% Level 5 100µs <=30% 10 100µs <=30%

1.00 If the inspection indicated when the calibrator applied to the upper frequency f2 higher than 500kHz measurement system, the index should be less than 0.03/f2.

This metric is only 2 for step voltage rectangular pulse sequence mode, the time interval between two consecutive T refers to the pulses of different polarity time. If the calibration is indicated when censorship is applied to the lower frequency f1 lower than 100kHz measurement system, the index should be greater than 1/f1.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

How to Download JJG 1115-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 1115-2015

$295.00