Scope

JJG 1105-2015 (Verification Regulation of Ammonia Gas Detectors) is available as an English-translated PDF.

JJG 1105-2015 — This Standard applies to measuring air or nitrogen gas analyzers for initial verification and detection alarm ammonia content of the subsequent verification and the use of checks.

Found what you need?

Document preview — JJG 1105-2015

National Standard of the People's Republic of China

ICS
17.020
Classification
A 61

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 Overview (1)
  • 3 Metering performance requirements (1)
  • 3.1 Indication error (1)
  • 3.2 Repeatability (1)
  • 3.3 Response Time (1)
  • 3.4 Stability (1)
  • 4 General Requirements (1)
  • 4.1 Appearance and structure (1)
  • 4.2 Marks, and logos (2)
  • 4.3 Energizing check (2)
  • 4.4 Insulation Resistance (2)
  • 4.5 Dielectric strength (2)
  • 4.6 Alarm function (2)
  • 5 Control of measuring instruments (2)
  • 5.1 Environmental test conditions (2)
  • 5.2 Calibration with standard materials and equipment (2)
  • 5.3 Verification Project (3)
  • 5.4 Verification Methods (4)
  • 5.5 Verification Results Processing (5)
  • 5.6 Test cycle (5)
  • Appendix A Test recording format (6)
  • Appendix B Test certificates/test results in the notice page format (7)

1 Scope (1)

2 Overview (1)

3 Metering performance requirements (1)

3.1 Indication error (1)

3.2 Repeatability (1)

3.3 Response Time (1)

3.4 Stability (1)

4 General Requirements (1)

4.1 Appearance and structure (1)

4.2 Marks, and logos (2)

4.3 Energizing check (2)

4.4 Insulation Resistance (2)

4.5 Dielectric strength (2)

4.6 Alarm function (2)

5 Control of measuring instruments (2)

5.1 Environmental test conditions (2)

5.2 Calibration with standard materials and equipment (2)

5.3 Verification Project (3)

5.4 Verification Methods (4)

5.5 Verification Results Processing (5)

5.6 Test cycle (5)

Appendix A test recording format (6)

Appendix B test certificates/test results in the notice page format (7)

Introduction

This procedure is based on JJF1002-2010 "national verification procedures write rules", JJF1001 "general purpose Volume terms and definitions "and JJF1059.1" Evaluation and Expression of Uncertainty in Measurement "basis and developed.

This procedure was first formulated.

Ammonia detector test procedures

1 Scope

The order applies to the measurement of ammonia content in the air or nitrogen gas analyzer and detector alarm (hereinafter referred to as analysis Instrument and alarm, collectively referred to as the instrument) initial verification, subsequent verification and the use of checks.

2 Overview

Instrument detection principle electrochemical, infrared sound and light, non-dispersive infrared chemiluminescence, UV and the like. Sampling Method There are two kinds of inhaled and diffusion, use is divided into fixed and portable. General Instrument by the sensor chamber, the sampling Components, electronic circuits, monitors and other components.

3 metering performance requirements

3.1 Indication error Indication error to meet the requirements of Table 1.

Specified in Table 1 the maximum permissible error Measuring range/(µmol/mol) analyzer alarm 0<=C<=50 ± 10% ± 10% 50 \u003cC<=1000 ±6% ±10%

3.2 Repeatability

Analyzer, the alarm repeatability relative standard deviation of not more than 2% and 3%.

3.3 Response Time

Inhaled Sampling Method instrument response time of less than 120s; diffusion Sampling Method instrument response time Room is not greater than 180s.

3.4 Stability

3.4.1 Zero Drift

Analyzer, the alarm zero drift does not exceed ± 1% FS, ± 2% FS.

3.4.2 Span drift

Analyzers, alarm span drift does not exceed respectively ± 2% FS, ± 3% FS.

4 General technical requirements

4.1 Appearance and structure

4.1.1 The instrument shall not affect the appearance of their normal work injury. Surface of the new instrument should be made smooth, paint Color uniform coating, no rust flaking phenomenon.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.

How to Download JJG 1105-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
10 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 1105-2015

$205.00