JJG 1093-2013Detectors of Mining Carbon Monoxide (English PDF)
矿用一氧化碳检测报警器检定规程
This is a limited preview
Buy now to download the full PDF (14 pages)
Need quotation for your management?
Get a formal quotation for JJG 1093-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
November 28, 2013
Implementation date
February 28, 2014
Scope
JJG 1093-2013 is the English-translated version of 矿用一氧化碳检测报警器检定规程.
JJG 1093-2013 - This standard applies to the mine using carbon monoxide detector alarm (hereinafter referred to as detection alarm) - the initial verification, testing and use of the follow-up examination.
Found what you need?
Document preview — JJG 1093-2013
National Standard of the People's Republic of China
- ICS
- 17.020
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Overview (1)
- 3 Metering performance requirements (1)
- 3.1 Measuring range and indication error (1)
- 3.2 Repeatability (1)
- 3.3 Response Time (1)
1 Scope (1)
2 Overview (1)
3 Metering performance requirements (1)
3.1 Measuring range and indication error (1)
3.2 Repeatability (1)
3.3 Response Time (1)
Drift 3.4 (2)
4 General Requirements (2)
4.1 Appearance and structure (2)
4.2 Mark and logo (2)
4.3 Energizing check (2)
4.4 Alarm function (2)
4.5 Adaptive power supply voltage (2)
Transmission distance 4.6 (2)
4.7 Insulation resistance (3)
5 Control of measuring instruments (3)
5.1 Test conditions (3)
5.2 Verification Project (4)
5.3 Verification Methods (4)
5.4 Verification Results Processing (7)
5.5 Test cycle (7)
Appendix A portable mine carbon monoxide detector alarm test records (8)
Appendix B Fixed mine carbon monoxide detection alarm test records (10)
Appendix C calibration certificate/test results of notice under section 2 format (13)
Appendix D calibration certificate Chapter 3 format (14)
Appendix E test results notice under section 3 format (15)
Introduction
This procedure based on JJF1002-2010 "national verification procedures writing rules" and JJF1001-2011 "Tong Metering terms and definitions "to develop, technical specifications and test methods referenced MT703-2008" Mine Portable Electrochemical carbon monoxide measuring device ", AQ6205-2006" Mine electrochemical carbon monoxide sensor type " JJG (coal) 09-98 "carbon monoxide detection alarm", JJG 915-2008 "carbon monoxide detector alarm" Wait. The regulations focus on the development of the process of verification method operability, and with current industry standards and effective terrestrial Similar product test procedures coordination and consistency.
This procedure was first formulated.
Mine carbon monoxide detector alarm verification procedures
1 Scope
The order applies to the mine using electrochemical principles carbon monoxide detector alarm (hereinafter referred to as detection alarm Device) initial verification, use and subsequent verification check.
2 Overview
Detection alarm for mine detection and alarm concentration of carbon monoxide gas in the operating environment.
Mainly composed of carbon monoxide detection alarm electrochemical sensors, electronic components and display section and other components, electrochemical Sensors convert the carbon monoxide gas concentration in the environment into electrical signals, then processed by an electronic component, and a concentration of Value displayed.
Depending on use, the detector alarm can be divided into portable (mining industry, known as alarm or measured Device) and fixed (known as sensors mining industry). Fixed detection alarm also has a value corresponding to the concentration of the letter no output function.
3 metering performance requirements 3.1 measuring range and indication error Detection alarm measurement range is divided into the following. (0 ~ 100) µmol/mol, (0 ~ 500) µmol /mol, (0 ~ 1000) µmol/mol, (0 ~ 2000) µmol/mol, (0 ~ 10000) µmol/mol, the unit is µmol/mol.
Display values detector alarm, fixed detector alarm output signal values (concentration of carbon monoxide in terms of value) and the standard deviation of the gas concentration (ie indication error detector alarm) shall comply with the requirements in Table 1.
Table 1 shows the value of the error detection alarm limit requirements
Measurement section, x µmol/mol Indication error Absolute error µmol/mol Relative error 0 \u003cx<=20 ±2 --20 \u003cx<=100 ±4 --100 \u003cx<=500 -- ±5 x > 500 -- ± 6
3.2 Repeatability
Repeatability should <=2%.
3.3 Response Time
Detection alarm response time of less than 45s.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.
How to Download JJG 1093-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
JJG 1093-2013
$315.00