JJG 1089-2013Verification Regulation of Osmometers (English PDF)
渗透压摩尔浓度测定仪
This is a limited preview
Buy now to download the full PDF (9 pages)
Need quotation for your management?
Get a formal quotation for JJG 1089-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
October 25, 2013
Implementation date
January 25, 2014
Scope
JJG 1089-2013 is the English-translated version of 渗透压摩尔浓度测定仪.
JJG 1089-2013 is the Chinese standard "Verification Regulation of Osmometers". Issued on 2013-10-25, in force from 2014-01-25.
Found what you need?
Document preview — JJG 1089-2013
National Standard of the People's Republic of China
- ICS
- 17.020
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Terminology and units of measurement (1)
- 4 Overview (1)
- 5 Metering performance requirements (1)
- 6 General Requirements (2)
- 6.1 Appearance (2)
- 6.2 Boot check (2)
- 7 Control of measuring instruments (2)
- 7.1 Verification Conditions (2)
- 7.2 Verification Project (2)
- 7.3 Verification Methods (3)
- 7.4 Test results processing (3)
- 7.5 Test cycle (3)
- Appendix A Test original record format (4)
- Appendix B Test certificates/test results in the notice page format (5)
1 Scope (1)
2 References (1)
3 Terminology and units of measurement (1)
4 Overview (1)
5 Metering performance requirements (1)
6 General Requirements (2)
6.1 Appearance (2)
6.2 Boot check (2)
7 Control of measuring instruments (2)
7.1 Verification Conditions (2)
7.2 Verification Project (2)
7.3 Verification Methods (3)
7.4 Test results processing (3)
7.5 Test cycle (3)
Appendix A test original record format (4)
Appendix B test certificates/test results in the notice page format (5)
Introduction
JJF1002-2010 "national verification procedures write rules", JJF1001-2011 "common terminology and measurement the definition of "together constitute the support of the protocol development of the basic family of specifications.
This procedure of "People's Republic of China Pharmacopoeia" (2010 edition) of the osmolarity of the analyzer requirements as the basis for the development.
This procedure was first formulated.
Osmolality analyzer test procedures
1 Scope
The order applies to the use of the principle of freezing point depression osmolality analyzer (hereinafter referred to as equipment) for the first time Test, test and subsequent use of checks.
2. References
People's Republic of China Pharmacopoeia (2010 edition) Appendix VH osmolarity assay for dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.
3 terminology and units of measurement 3.1 capacity osmolarity Osmolarity Per liter of solution refers to the number of moles of solute in the permeate, Osmol·L-1 units or mOsmol·L-1, 1Osmol·L-1 = 1000mOsmol·L-1.
3.2 wt osmolality Osmolality Refers to the solute per kilogram of solvent penetration mole number of units Osmol · kg-1 or mOsmol · kg-1, 1Osmol · kg-1 = 1000mOsmol · kg-1.
4 Overview
The instrument works by indirectly measuring the osmolarity of the solution using the freezing point depression. The temperature measurement Probe immersed in the center of the solution, and fell to the instrument cooling slots. Start the cooling system, when the temperature dropped below freezing solution the next, the instrument uses an oscillator (or metal probe) induced by freezing the solution, automatically record the temperature of the freezing point depression. instrument Data processing system after the temperature of the freezing point depression of the data processed by the terms of osmolality.
Instrument usually consists of refrigeration systems, temperature measurement system, temperature control system, data processing system and a display system and other parts composition.
5 metering performance requirements Instrumental performance indicators are shown in Table 1.
Table 1 test and measurement of project performance indicators
No. test items measured performance indicators
1 Indication error
Not more than 400mOsmol · kg-1 when no more than ± 6mOsmol · kg-1 Concentrations greater than 400mOsmol · kg-1 when no more than ± 1.5%
2 Repeatability <=2mOsmol · kg-1
3 Stability <=2mOsmol · kg-1
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
How to Download JJG 1089-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
JJG 1089-2013
$205.00