JJG 1085-2013Verification Regulation of Reference Meters for Electrical Energy (English PDF)
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for JJG 1085-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
January 1, 1970
Implementation date
January 1, 1970
Scope
JJG 1085-2013 (Verification Regulation of Reference Meters for Electrical Energy) is available as an English-translated PDF.
JJG 1085-2013 — This standard applies to the rated frequency of 50Hz or 60Hz initial verification standard electronic energy meter, follow-up test and use checks.
Found what you need?
Document preview — JJG 1085-2013
National Standard of the People's Republic of China
- ICS
- 17.220
- Classification
- A 55
- Replacing
- JJG 596-1999
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Overview (1)
- 4 Metering performance requirements (1)
- 4.1 Basic error (1)
- 4.2 Input, output and display (3)
- 4.3 Control (3)
- 4.4 Start and stop (3)
- 4.5 AC voltage test and insulation resistance (4)
- 4.6 Measurement repeatability (4)
- 5 General technical requirements (4)
- 5.1 Appearance (4)
- 6 Control of measuring instruments (4)
- 6.1 For initial verification and subsequent verification (4)
- 6.2 Meter calibration standard should have the basic conditions (4)
- 6.3 Calibration means determining the standard meter energy measurement basic error (6)
- 6.4 Meter standard test items (7)
- 6.5 Verification Methods (7)
- 6.6 Test results processing and verification cycle (13)
- Appendix A Test wiring diagram (14)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Metering performance requirements (1)
4.1 Basic error (1)
4.2 Input, output and display (3)
4.3 Control (3)
4.4 Start and stop (3)
4.5 AC voltage test and insulation resistance (4)
4.6 Measurement repeatability (4)
5 General technical requirements (4)
5.1 Appearance (4)
6 Control of measuring instruments (4)
6.1 for initial verification and subsequent verification (4)
6.2 Meter calibration standard should have the basic conditions (4)
6.3 Calibration means determining the standard meter energy measurement basic error (6)
6.4 Meter standard test items (7)
6.5 Verification Methods (7)
6.6 Test results processing and verification cycle (13)
Appendix A test wiring diagram (14)
B rounding method of measurement data appendix (16) Appendix C Standard Meter Verification original record format (17) Appendix D calibration certificate/test results in the notice page format style (p. 2) (19) Appendix E calibration certificate/test results test results page notice Shape (page 3) (20)
Introduction
The procedures in place JJG 596-1999 "electronic meters" standard meter section.
The procedure for JJG 596-1999 "electronic meters" standard meter section be revised, the main changes as follows.
--- Based JJF1002-2010 "national verification procedures to write rules" for the editorial changes;
--- Procedure name from "electronic meters" to "standard meter";
--- This procedure applies only to electronic verification standard meter;
--- Standard-meter basic error of energy measurement verification device according to JJG 597-2005 "AC power Meter testing equipment "revised accordingly.
Standard energy meter testing procedures
1 Scope
The order applies to the rated frequency of 50Hz or 60Hz initial verification of standard electronic energy meter, follow-up inspection and given the use of checks.
2. References
This procedure references the following documents.
JJG 597-2005 AC power meter testing equipment GB/T 17215.701-2011 standard meter for dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.
3 Overview
Standard electrical energy meter is a measure of the energy meter. And it is usually designed to work in a controlled laboratory environment to obtain the highest accuracy and stability. Usually by the standard meter voltage input module, current input module, multiplication Module, the digital signal processing unit, an error processing module and a display module.
Standard power meter can be used independently, but also as a master meter standard device verification equipment use.
4 metering performance requirements 4.1 basic error
4.1.1 Basic error expressed as a percentage relative error. Under the conditions specified in 6.2, the basic standard meter Error limit (referred to as the basic error limit) shall not exceed the specified in Table 1 and Table 2.
4.1.2 in the test cycle, the basic error of the standard meter shall not exceed the values in Table 1 and Table 2. Standard Electric Menu in the absolute value of the basic error of the test cycle change amount shall not exceed the absolute value of the basic error limit.
The basic error of the absolute value of the amount of change in the 4.1.3 standard energy meter 24h shall not exceed the absolute value of the basic error limit 1/5.
4.1.4 Warm-up time from the end date, the standard meter continuous work 8h, basic error should not exceed the basic error Limit and basic error shall not exceed the amount of change in the absolute value specified in Table 3.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Referenced standards
How to Download JJG 1085-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
Secure payment via Stripe
Payments accepted
JJG 1085-2013
$375.00