JJG 1079-2013Verification Regulation of Comprehensive Calibrators for Test Equipment of Railway Track Signal (English PDF)
铁路轨道信号测试设备综合校验装置
This is a limited preview
Buy now to download the full PDF (16 pages)
Need quotation for your management?
Get a formal quotation for JJG 1079-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
January 6, 2013
Implementation date
April 6, 2013
Scope
JJG 1079-2013 is the English-translated version of 铁路轨道信号测试设备综合校验装置.
JJG 1079-2013 - This standard applies to railroad track signal integrated test equipment calibration device (hereinafter referred to as integrated calibration device) initial verification, follow-up test and use checks.
Found what you need?
Document preview — JJG 1079-2013
National Standard of the People's Republic of China
- ICS
- 17.220
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Overview (1)
- 3 Metering performance requirements (1)
- 3.1 Single-frequency output (1)
- 3.2 Frequency shift output (1)
- 3.3 25Hz, 50Hz Phase Detecting Track signal output (2)
- 3.4 Ac count track signal output (2)
- 3.5 Compensation capacitor (2)
1 Scope (1)
2 Overview (1)
3 Metering performance requirements (1)
3.1 Single-frequency output (1)
3.2 Frequency shift output (1)
3.3 25Hz, 50Hz Phase Detecting Track signal output (2)
3.4 Ac count track signal output (2)
3.5 Compensation capacitor (2)
Impedance 3.6 (2)
4 General Requirements (2)
5 Control of measuring instruments (2)
5.1 Verification Conditions (2)
5.2 Verification Project (3)
5.3 Verification Methods (3)
5.4 Verification Results Processing (8)
5.5 Test cycle (8)
Appendix A railway track signal integrated test equipment calibration device calibration record format (9)
APPENDIX B calibration certificate and test results in the notice page format (18)
Introduction
JJF1002 "national verification procedures write rules", JJF1001 "common measurement terms and definitions" JJF1059 "Evaluation and Expression of Uncertainty in Measurement" together constitute the support of the protocol development of the basic series specification.
The regulations are based on the actual use of the technical requirements.
This procedure was first formulated.
Comprehensive calibration device verification procedures railroad track signal test equipment
1 Scope
The order applies to the first railway track signal integrated test equipment calibration device (hereinafter referred to as integrated calibration device) Second test, verification and subsequent use of checks.
2 Overview
Comprehensive calibration device is mainly used in railway track signal line test equipment test and calibration. Its main functions are.
Single-frequency output signal frequency, voltage and current; frequency shift signal (including the center frequency of 550Hz, 650Hz, 750Hz, 850Hz frequency shift of the signal, ZPW-2000, UM71, WG-21A, etc.) frequency, voltage, Stream; 25Hz, 50Hz voltage phase sensitive track signal phase; voltage ac counting track signals, time intervals, etc.
Standard signal, standard compensation capacitor and impedance.
3 metering performance requirements 3.1 single-frequency output
3.1.1 Frequency
Output ranges from 5Hz ~ 3kHz, the maximum permissible error shall not exceed ± 0.03Hz.
3.1.2 Voltage
(5 ~ 25) Hz frequency band output range (0.1 ~ 10) V, 25Hz ~ 3kHz band output range (0.1 ~ 400) V, the maximum permissible error shall not exceed ± 0.5%.
3.1.3 Current
5Hz ~ 3kHz band output range (50 ~ 500) mA, the maximum permissible error shall not exceed ± 0.5%, by induction coil output current range of 50mA ~ 20A.
3.2 Frequency Shift Output 3.2.1 frequency shift (center frequency of 550Hz, 650Hz, 750Hz, 850Hz frequency shift signal) 3.2.1.1 upper and lower frequencies. output range (460 ~ 940) Hz, the maximum permissible error shall not exceed ± 0.03Hz.
3.2.1.2 The low frequency range. low frequency modulation frequency output range (6 ~ 30) Hz, shall not exceed the maximum permissible error ± 0.003Hz.
3.2.1.3 Voltage. shift in frequencies, the output range (0.1 ~ 400) V, shall not exceed the maximum permissible error ± 0.5%.
3.2.1.4 Current. shift frequencies, the output range (50 ~ 500) mA, shall not exceed the maximum permissible error ± 0.5%, by the induction coil output current range of 50mA ~ 20A.
3.2.2 ZPW-2000, UM71, WG-21A 3.2.2.1 upper and lower frequencies. output range (1.6 ~ 2.7) kHz, shall not exceed the maximum permissible error ± 0.03Hz.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
How to Download JJG 1079-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
JJG 1079-2013
$315.00