JJG 1078-2012Verification Regulationof X-ray Radiation Sources for Medical Computed Radiography System and Digital Radiography System (English PDF)
医用数字摄影(CR、DR)系统 X射线辐射源
This is a limited preview
Buy now to download the full PDF (11 pages)
Need quotation for your management?
Get a formal quotation for JJG 1078-2012 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
June 18, 2012
Implementation date
September 18, 2012
Scope
JJG 1078-2012 is the English-translated version of 医用数字摄影(CR、DR)系统 X射线辐射源.
JJG 1078-2012 is the Chinese standard "Verification Regulationof X-ray Radiation Sources for Medical Computed Radiography System and Digital Radiography System". Issued on 2012-06-18, in force from 2012-09-18.
Found what you need?
Document preview — JJG 1078-2012
National Standard of the People's Republic of China
- ICS
- 17.240
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Terminology and units of measurement (1)
- 3.1 The term (1)
- 3.2 Units of measurement (2)
- 4 Overview (2)
- 5 Metering performance requirements (2)
- 5.1 Radiation output of air kerma (2)
1 Scope (1)
2 References (1)
3 Terminology and units of measurement (1)
3.1 The term (1)
3.2 Units of measurement (2)
4 Overview (2)
5 Metering performance requirements (2)
5.1 Radiation output of air kerma (2)
Repeatability 5.2 radiation output (2)
5.3 Quality radiation output (2)
Spatial resolution 5.4 (2)
5.5 Low contrast resolution (2)
5.6 Image uniformity (2)
5.7 Light field and the radiation field consistency (2)
5.8 Effective focal spot size (2)
5.9 X-ray tube voltage (2)
6 General Requirements (3)
7 Control of measuring instruments (3)
7.1 Test conditions (3)
7.2 Test items and test methods (3)
7.3 Verification Results Processing (6)
7.4 Test cycle (7)
Appendix A CR, DR performance measurement phantom technical requirements (8)
Appendix B calibration certificate and test results notice (within the page) format (9)
Appendix C test original record format (10)
Introduction
This procedure is a combination of the current situation of medical digital photography equipment performance and image quality evaluation, and refer to the relevant International recommendations and national standards on the basis of established.
Medical digital photography (CR, DR) system X-ray radiation source verification procedures
1 Scope
The order applies to medical X-ray imaging computer system (ComputedRadiographySystem, Acronym CR systems), digital X-ray imaging system (DigitalRadiographySystem, referred to as DR systems) X-ray Emitter initial verification, subsequent verification and the use of checks.
This procedure does not apply to breast, and dental digital photography system test X-ray radiation source.
2. References
This procedure references the following documents.
JJG 744-2004 diagnostic X-ray radiation JJF1035-2006 ionizing radiation measurement terms and definitions GB 9706.3-2000 Medical electrical equipment - Part 2. High-voltage generator means of diagnostic X-ray generator Requirements for safety GB/T 10149 X-ray equipment for medical terminology and symbols AAPMREPORTNO.93- ray image forming system acceptance testing and quality control (Acceptance TestingandQualityControlofPhotostimulableStoragePhosphorImagingSystems) WS76-2011 conventional X-ray diagnostic equipment for medical image quality control testing specification GB Z187-2007 computer X-ray photography (CR) quality control testing specification YY/T 0741-2009 digital medical X-ray imaging system dedicated technical conditions for dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.
3 terminology and units of measurement JJF1035-2006 and GB/T 10149 and defined by the following terms and definitions apply to this procedure.
3.1 Terms
3.1.1 Computer X-ray imaging system computedradiographysystem Using imaging plates instead of intensifying screen film can be reused as a carrier through the X-ray exposure, and then the laser scanning Access to equipment image information. Acronym CR system.
3.1.2 The digital X-ray imaging system digitalradiographysystem Using digital X-ray image detector technology X-ray imaging devices. Acronym DR system.
3.1.3 imaging plate (IP) Using an X-ray storage luminescent material (such as fluorine, barium halide) is made of an X-ray detector plane.
3.1.4 Spatial resolution Under specified measurement conditions, visually discernible predetermined set of graphic line or minimum spatial frequency line pair group unit
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
How to Download JJG 1078-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
JJG 1078-2012
$195.00