JJG 1077-2012 — This standard applies to air or other gas composition measurements of ozone concentration ozone gas analyzer (hereinafter referred to as "equipment") of the initial verification, testing and use of follow-up checks.
Found what you need?
Document preview — JJG 1077-2012
National Standard of the People's Republic of China
- ICS
- 17.020
- Classification
- A 61
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Overview (1)
- 3 Metering performance requirements (1)
- 3.1 Indication error (1)
- 3.2 Repeatability (1)
- 3.3 Response Time (1)
- 3.4 Zero drift and span drift (1)
- 4 General Requirements (1)
- 4.1 Appearance and energizing check (1)
- 4.2 Insulation Resistance (2)
- 4.3 Dielectric strength (2)
- 5 Control of measuring instruments (2)
- 5.1 Verification Conditions (2)
- 5.2 Calibration with standard appliances and equipment (2)
- 5.3 Verification Project (2)
- 5.4 Verification Methods (3)
- 5.5 Verification Results Processing (5)
- 5.6 Test cycle (5)
- Appendix A Calibration certificate/test results in the notice page format (6)
- Appendix B Test recording format (9)
1 Scope (1)
2 Overview (1)
3 Metering performance requirements (1)
3.1 Indication error (1)
3.2 Repeatability (1)
3.3 Response Time (1)
3.4 Zero drift and span drift (1)
4 General Requirements (1)
4.1 Appearance and energizing check (1)
4.2 Insulation Resistance (2)
4.3 Dielectric strength (2)
5 Control of measuring instruments (2)
5.1 Verification Conditions (2)
5.2 Calibration with standard appliances and equipment (2)
5.3 Verification Project (2)
5.4 Verification Methods (3)
5.5 Verification Results Processing (5)
5.6 Test cycle (5)
Appendix A calibration certificate/test results in the notice page format (6)
Appendix B test recording format (9)
Introduction
This procedure is based on JJF1002-2010 "national verification procedures write rules", JJF1001 "general purpose Volume terms and definitions "and JJF1059" Evaluation and Expression of Uncertainty in Measurement "provisions enacted.
The procedures include the subject of the instrument are. the use of ozone gas applications for environmental monitoring, research and analysis, and chemical analyzer Tester ozone gas and ozone alarm chemical industry, disease prevention and control, pollution control and other industries use. Range can be from (10-9 ~ 10-4) mol/mol.
The rules of verification of the main metering projects are.
--- Indication error in the relative error of the measured value representation;
--- Relative standard deviation of repeatability of measurements indicated;
--- To measure the response time is the time required to stabilize the value of 90% representation;
--- Full scale (FS) relative error represented stability, including stability zero drift and span drift.
The main criteria of the present rules of order are.
--- Ozone standard gas generator. Yes (0 ~ 1) µmol/mol range, the maximum permissible absolute error is less More than 2.0%; for ( > 1 ~ 400) µmol/mol range, not the absolute value of the maximum permissible error at 5.0%.
--- Because ozone is an extremely lively and strong oxidizing gas can not be stored in cylinders or containers, only dynamic it happens now with the current.
This procedure is the first national verification procedures developed.
Ozone gas analyzer test procedures
1 Scope
The order applies to the measurement of air or other gas components in the ozone content of the ozone gas analyzer (hereinafter referred to as "Instrument") of the initial verification, use and subsequent verification check.
2 Overview
Instrument detection principle generally include UV absorption principle, the principle of electrochemical sensors, semiconductor gas sensor original Physical and chemical principles of discoloration. By sampling methods are inhaled and spread two. General Instrument by the sampling device, sensing module Block, electronic circuits, displays and other components. Component being tested by the sensor into electrical signals, and then by electronic circuitry Into a digital signal showing the concentration of ozone.
3 metering performance requirements
3.1 Indication error Indication error should meet the requirements of Table 1.
Table 1 shows the error
Range Range (R *, µmol/mol) indication error 0.10 \u003cR<=1.00 ±6%FS 1.00 \u003cR<=400 ±12%FS * R range for the instrument; FS. full scale instrument.
3.2 Repeatability
Not more than 2% repeatability.
3.3 Response Time
Inhaled Sampling Method instrument response time of less than 60s; diffusion Sampling Method instrument response time not more than 180s.
3.4 zero drift and span drift
3.4.1 Zero Drift
For fixed equipment, continuous operation 4h, zero drift should not exceed ± 1% FS. For non-fixed instruments without Claim.
3.4.2 Span drift
For fixed equipment, continuous operation 4h, span drift should not exceed ± 2% FS. For non-fixed instruments without Claim.
4 General technical requirements 4.1 appearance and power check
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
How to Download JJG 1077-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1201-2024 — Digital Tyre Pressure Gauges
JJG 1202-2024 — Long Distance Transmissible Pressure Gauges
JJG 746-2024 — Ultrasonic Flaw Detectors
Secure payment via Stripe
Payments accepted
JJG 1077-2012
$324.00