JJG 1075-2012Verification Regulation of High Voltage Standard Capacitors (English PDF)

高压标准电容器检定规程

Preview PDF

This is a limited preview

Buy now to download the full PDF (12 pages)

Need quotation for your management?

Get a formal quotation for JJG 1075-2012 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

March 2, 2012

Implementation date

June 2, 2012

Scope

JJG 1075-2012 is the English-translated version of 高压标准电容器检定规程.

JJG 1075-2012 - This standard applies to the rated frequency of 50 (60) Hz, rated voltage of 10kV and above shielded high voltage standard capacitor electrode structure of the initial verification, testing and use of follow-up checks.

Found what you need?

Document preview — JJG 1075-2012

National Standard of the People's Republic of China

ICS
17.220

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Overview (1)
  • 4 Metering performance requirements (1)

1 Scope (1)

2 References (1)

3 Overview (1)

4 Metering performance requirements (1)

Capacitance error 4.1 (1)

4.2 Dissipation Factor (1)

4.3 Voltage coefficient (2)

4.4 Included a capacitive voltage divider (2)

4.5 Stability (2)

5 General Requirements (2)

5.1 Nameplate, terminals and marking (2)

5.2 Dielectric strength (2)

5.3 Pressure gauge (3)

5.4 Protection device (3)

6 Control of measuring instruments (3)

6.1 Verification condition (3)

6.2 Verification Project (4)

6.3 Verification Methods (4)

Processing 6.4 Verification Results (6)

6.5 Test cycle (6)

Appendix A test original record format (7)

Appendix B test certificates/test results in the notice page format (9)

Introduction

This procedure based on JJF1002-2010 "national verification procedures write rules" establishment.

This procedure uses a reference JB1811-1992 "compressed gas capacitor" relevant compressed gas capacitor measurability Energy requirements and with JJG 496-1996 "frequency high voltage divider" has been promulgated, JJG 563-2004 "high-voltage Yung bridge ", JJG 1021-2007" power transformer "and JJG 314-2010" measuring voltage transformer "phase coordination.

This procedure is the first national verification procedures developed.

High voltage standard capacitor test procedures

1 Scope

The order applies to the nominal frequency of 50 (60) Hz, rated voltage of 10kV or more, and the shield electrode structure High voltage standard capacitor initial verification, subsequent verification and the use of checks.

2. References

This procedure refers to the following documents.

JJG 496-1996 frequency high voltage divider JJG 563-2004 high voltage capacitance bridge GB/T 16927.1 High-voltage test techniques Part 1. General test requirements for dated references, only the edition applies to the procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.

3 Overview

High voltage standard capacitor is stability of capacitance and dissipation factor of the order of 10-4 or more have reached a high voltage precision Capacitors. Its structure includes a high voltage electrode with a metal electrode material, electrode and a shielding electrode measurements, it must Edge structure includes supporting the high voltage electrode and the insulation of high voltage electrode and the shield electrode holder fixed measurement. gas Insulated high voltage standard capacitor electrode sealed in a pressure vessel, the vessel is filled with SF6, N2, CO2 such must Edge of the gas; standard insulated high voltage electrode is vacuum sealed in a container capacitor in a high vacuum. Loss of tiny solid and Liquid materials may also be used as a standard high-voltage capacitor dielectric.

High voltage standard capacitor of the most important performance measurement of electrical capacity and the loss factor and the operating voltage correlation (Referred to as the voltage coefficient) is extremely small, the order of 10-5 to reach. Therefore their capacity and dissipation factor can be lower Voltage (for example, 10% of the rated voltage) calibration, and then under a high voltage as capacitance and loss factor of the standard device use.

4 metering performance requirements 4.1 capacitance error Under reference conditions shown in Table 1, the high voltage standard capacitor capacitance found on the nameplate or certificate given nominal capacitance Deviation shall not exceed ± 0.3%.

NOTE. When the nameplate value with a valid certificate value inconsistent with a valid certificate values prevail. Articles in the case of the following nameplate value with a valid certificate They are treated similarly inconsistent values.

4.2 Loss Factor

The nominal reference conditions in table 1, high voltage standard capacitor loss factor found on the nameplate or certificate given Loss of value due to deviation shall not exceed ± 1 × 10-4.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.

How to Download JJG 1075-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
12 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 1075-2012

$255.00