JJG 1072-2011Verification Regulation of High Voltage and Value D.C.Resistors (English PDF)
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for JJG 1072-2011 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
November 30, 2011
Implementation date
May 30, 2012
Scope
JJG 1072-2011 (Verification Regulation of High Voltage and Value D.C.Resistors) is available as an English-translated PDF.
JJG 1072-2011 — This standard applies to maximum nominal operating voltage greater than 1kV, the total resistance is greater than 10M�� DC high voltage high value resistors (hereinafter referred to as high-pressure high-impedance device) the initial verification, testing and use of follow-up checks.
Found what you need?
Document preview — JJG 1072-2011
National Standard of the People's Republic of China
- ICS
- 47.220
- Classification
- A 55
- Replacing
- JJG 166-1993
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Overview (1)
- 4 Metering performance requirements (1)
- 4.1 Accuracy class and maximum permissible error (1)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Metering performance requirements (1)
4.1 Accuracy class and maximum permissible error (1)
Voltage variation 4.2 (2)
4.3 Residual Resistance (2)
4.4 Switch contact resistance variation (2)
5 General Requirements (2)
5.1 Appearance and identification (2)
5.2 Structure (2)
5.3 Insulation resistance (3)
5.4 Frequency voltage withstand test (3)
5.5 Temperature, relative humidity nominal conditions of use (3)
6 Control of measuring instruments (3)
6.1 Verification condition (3)
6.2 Test items and test methods (4)
6.3 Verification Results Processing (5)
6.4 Test cycle (6)
Appendix A DC high voltage high value resistor measuring principle (7)
Appendix B test original record format (9)
C calibration certificate/test results in the notice page format Shape appendix (11)
Introduction
JJF1002-2010 "national verification procedures to write rules" rules of order preparation is based.
JJG 1072-2011 "DC high voltage high value resistor" is JJG 166-1993 "DC resistance" for the group Foundation, on which the DC high voltage high value resistor (hereinafter referred to as high-pressure high-impedance device) amended section and separate developed Test procedures. Compared with JJG 166-1993, the main technical changes are as follows.
--- The order applies to the use of a nominal voltage greater than 1kV, the total resistance is greater than 10Mohm the high-pressure high-impedance detection Set (see 1);
--- Zero switching device block at high-pressure high-impedance device, when all the switches are set to zero, the output of the residual power Direct resistance shall not be greater than 1ohm (see 4.3);
--- High-voltage switching device with a high impedance device, the resistance caused by the deterioration of the contact switch contacts shall not be greater than the direct 0.1ohm (we see 4.4);
--- Clear nominal operating voltage (or current) (see 5.1);
--- Emphasized the high voltage high impedance device should be placed at least 24 hours at reference conditions, so that the internal temperature and humidity Consistent with the environment (see 6.1.2);
--- Simplifies the residual resistance measurement and switch contact resistance variation calculation (see 6.2.2.4,6.2.2.5);
--- Basic error of measurement is given using op amps partial pressure method, the partial pressure method and bridge method three measurement principle (see Annex Record A);
--- Resistance value rounding interval regulations have been simplified (see 6.3.2);
--- Increasing the "verification original record format" (see Appendix B), and "verification certificate and test results notice the inside pages Format "(see Appendix C).
DC high voltage high value resistor test procedures
1 Scope
DC high voltage electrical high value of the order applies to the use of the maximum nominal voltage greater than 1kV, the total resistance is greater than 10Mohm Resistor (hereinafter referred to as high-pressure high-impedance device) initial verification, use and subsequent verification check.
This procedure does not apply to active and passive analog resistor in the circuit is not suitable for installation as a permanent element Resistor.
2. References
This procedure refers to the following documents.
JJF1001 common measurement terms and definitions JJF1059 Evaluation and Expression of Uncertainty in Measurement JJF1094 measuring instrument characteristics evaluation JB/T 8225-1999 Laboratory DC resistor for dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.
3 Overview
High voltage high impedance is high impedance and how the value of the high-pressure single-valued high-pressure high-impedance device, mainly used for insulation resistance meter (megger) Verification. Multi-value high-pressure high-impedance typically consists of several decade resistor pad series, each of the disc by the decimal equivalent resistance Single-value resistor and step switch composed of not less than the minimum step resistance 100ohm; part of a multi-valued uses high-pressure high-impedance end Button-type structure, or a combination of the above two forms.
4 metering performance requirements 4.1 accuracy class and the maximum permissible error at reference conditions, high voltage high impedance device each decade resistor pad or button on each side can have its own resistor accuracy, etc.
Level and the nominal operating voltage.
High voltage high impedance device each decade resistor pad or button on each end resistance corresponding accuracy class and the maximum permissible errors shall be Specified in Table 1.
Table 1 Accuracy class and maximum permissible error
Accuracy class 0.2 0.5 Level 1 Level 2 510 the maximum permissible error ± 0.2% ± 0.5% ± 1% ± 2% ± 5% ± 10% High voltage high impedance indication error by the relative error, said.
delta = Rn-RxRx × 100% (1)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
How to Download JJG 1072-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
Secure payment via Stripe
Payments accepted
JJG 1072-2011
$255.00