JJG 1070-2011Verification Regulation of Standard Hydrophones in the Frequency Range 0.5 MHz to 5 MHz (Two-transducer Reciprocity Method) (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for JJG 1070-2011 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

July 4, 2011

Implementation date

October 4, 2011

Scope

JJG 1070-2011 (Verification Regulation of Standard Hydrophones in the Frequency Range 0.5 MHz to 5 MHz (Two-transducer Reciprocity Method)) is available as an English-translated PDF.

JJG 1070-2011 — This standard applies to the frequency range of 0. 5MHz ~ 5MHz used standard hydrophone initial verification, testing and use of follow-up checks.

Found what you need?

Document preview — JJG 1070-2011

National Standard of the People's Republic of China

ICS
17.140
Classification
A 59

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • 1 Scope (1)
  • 2. Referenced Documents (1)
  • 3 Terminology and units of measurement (1)
  • 4 Overview (2)
  • 5 Metering performance requirements (2)
  • 5.1 Of the work (2)
  • 5.2 Free field [voltage] sensitivity level (2)
  • 5.3 Free field [voltage] sensitivity level frequency response (2)
  • 6 General Requirements (2)
  • 6.1 General Requirements (2)
  • 6.2 Materials and Structures (2)
  • 6.3 Mark and factory data (3)
  • 7 Control of measuring instruments (3)
  • 7.1 Test conditions (3)
  • 7.2 Verification Project (4)
  • 7.3 Verification Methods (5)
  • 7.4 Verification Results Processing (7)
  • 7.5 Test cycle (7)
  • Appendix A Calculation of the effective radius of the transducer (8)
  • Appendix B Transducer reciprocity and non-linear test method (9)
  • Appendix C Calculated correction factor k (10)
  • Appendix D Calibration certificate and test results of notice-page format (12)

0.5 MHzto5MHz (Two-transducerReciprocityMethod)

Issued on. 2011-07-04 2011-10-04 implementation the State Administration of Quality Supervision, Inspection and Quarantine released 0.5MHz ~ 5MHz standard hydrophone (B transducer reciprocity method) test procedures the regulations by the State Administration of Quality Supervision, Inspection and Quarantine approved on July 4, 2011, and from from October 4, 2011 into effect.

Focal point. the National Committee of the acoustic measurement technology Drafted by. China Shipbuilding Industry Corporation seventh fifteen Institute China Institute of Metrology the measurement procedure commissioned the National Technical Committee is responsible for interpreting acoustics the drafters of the regulations.

Wangyue Bing (China Shipbuilding Industry Corporation seventh fifteen Institute) Huang Yongjun (China Shipbuilding Industry Corporation seventh fifteen Institute) Yang Ping (China Institute of Metrology) He Tao (China Shipbuilding Industry Corporation seventh fifteen Institute) table of Contents

1 Scope (1)

2 Referenced Documents (1)

3 Terminology and units of measurement (1)

4 Overview (2)

5 Metering performance requirements (2)

5.1 of the work (2)

5.2 Free field [voltage] sensitivity level (2)

5.3 Free field [voltage] sensitivity level frequency response (2)

6 General Requirements (2)

6.1 General Requirements (2)

6.2 Materials and Structures (2)

6.3 Mark and factory data (3)

7 Control of measuring instruments (3)

7.1 Test conditions (3)

7.2 Verification Project (4)

7.3 Verification Methods (5)

7.4 Verification Results Processing (7)

7.5 Test cycle (7)

Appendix A calculation of the effective radius of the transducer (8)

Appendix B transducer reciprocity and non-linear test method (9)

Appendix C calculated correction factor k (10)

Appendix D calibration certificate and test results of notice-page format (12)

Measurement Uncertainty Appendix E Examples (14) 0.5MHz ~ 5MHz standard hydrophone (two transducer reciprocity method) test procedures the procedure using the national standard GB/T 15611-1995 "high frequency acoustic hydrophone calibration" in the two transducers Reciprocity law.

1 Scope

This procedure is applied at a frequency standard hydrophone within 0.5MHz ~ 5MHz range used for initial verification, Verification and subsequent use of the check.

2 Citations

The regulations cited in the following documents.

JJF1001-1998 common measurement terms and definitions JJF1034-2005 acoustic measurement terminology and definitions GB/T 3102.7-1993 Quantities and units of acoustics GB/T 3223-1994 Acoustics underwater acoustic transducer free-field calibration method GB/T 3947-1996 Acoustics Terminology GB/T 15611-1995 high frequency acoustic hydrophone calibration IEC 62127-2:2007 ultrasound - Hydrophones - Part II. up to 40MHz frequency ultrasound field school Associate (Ultrasonics-Hydrophones-Part 2. Calibrationforultrasonicfieldsupto40MHz) when using this procedure, it should pay attention to using the currently valid version of the documents cited.

3 terminology and units of measurement this procedure uses JJF1001-1998, JJF1034-2005, GB/T 3947-1996 and the related terms definition.

This procedure uses quantities and units GB/T 3102.7-1993 prescribed.

NOTE. If no special instructions, this procedure all the voltage, current, sound pressure values refer to valid values.

3.1 from Easy calibration self-reciprocitycalibration Using only reciprocal transducer and a reflector made free-field reciprocity calibration.

NOTE. Self-calibration is generally easy to apply to the high-frequency hydrophones.

3.2 two transducers reciprocity calibration two-transducerreciprocitycalibration by the auxiliary transducer generates and easily via self calibration value be known sound field hydrophone calibration methods.

3.3 Apparent send current response apparenttransmittingcurrentresponse Assuming perfect plane wave measurement conditions, the plane wave received by the sound pressure applied to the input terminal of the current ratio.

Symbols. S * 1

Unit. Pa · m/A

3.4 apparent free field [voltage] sensitivity apparentfree-field [voltage] sensitivity Under the assumption that the ideal plane wave measurement conditions, the open circuit voltage output of the hydrophone and hydrophone introduced in free field Than the sound pressure at the position of the acoustic center of its existence before.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

How to Download JJG 1070-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 1070-2011

$315.00