JJG 1066-2011Verification regulation of precision centrifuge (English PDF)
This is a limited preview
Buy now to download the full PDF (23 pages)
Need quotation for your management?
Get a formal quotation for JJG 1066-2011 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
April 12, 2011
Implementation date
July 12, 2011
Scope
JJG 1066-2011 (Verification regulation of precision centrifuge) is available as an English-translated PDF.
JJG 1066-2011 — This standard applies to accuracy class 0. 1 ~ 0. 0001 precision centrifuge (hereinafter referred to as centrifuges) of the initial verification, testing and use of follow-up checks.
Found what you need?
Document preview — JJG 1066-2011
National Standard of the People's Republic of China
- ICS
- 17.160
- Classification
- A 53
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- 1 Scope (1)
- 2. Referenced Documents (1)
- 3 Terms (1)
- 4 Overview (1)
- 4.1 Principle and structure (1)
- 4.2 Classification (2)
- 4.3 Purpose (2)
- 5 Metering performance requirements (2)
- 5.1 Key Features (2)
- 5.2 Other properties (3)
- 6 General Requirements (3)
- 6.1 Appearance requirements and accessories (3)
- 6.2 Other technical requirements (3)
- 7 Control of measuring instruments (3)
- 7.1 Test conditions (3)
- 7.2 Verification Project (4)
- 7.3 Inspection methods and data processing (5)
- 7.4 Verification Results processing (11)
- 7.5 Test cycle (11)
- Appendix A Sophisticated centrifuge testing methods and other performance data processing (12)
- Appendix B Centrifuge test the original record format (the main test items) (23)
- Appendix C Centrifuge test the original record format (optional item) (26)
- Appendix D Test certificate-page format (29)
- Appendix E Test results in the notice page format (30)
1 Scope (1)
2 Referenced Documents (1)
3 Terms (1)
4 Overview (1)
4.1 Principle and structure (1)
4.2 Classification (2)
4.3 Purpose (2)
5 Metering performance requirements (2)
5.1 Key Features (2)
5.2 Other properties (3)
6 General Requirements (3)
6.1 Appearance requirements and accessories (3)
6.2 Other technical requirements (3)
7 Control of measuring instruments (3)
7.1 Test conditions (3)
7.2 Verification Project (4)
7.3 Inspection methods and data processing (5)
7.4 Verification Results processing (11)
7.5 Test cycle (11)
Appendix A sophisticated centrifuge testing methods and other performance data processing (12)
Appendix B centrifuge test the original record format (the main test items) (23)
Appendix C centrifuge test the original record format (optional item) (26)
Appendix D test certificate-page format (29)
Appendix E test results in the notice page format (30)
Precision centrifuge test procedures
1 Scope
The order applies to accuracy class 0.1 ~ 0.0001 precision centrifuge (hereinafter referred to as centrifuges) first Second test, verification and subsequent use of checks.
2 Citations
GJB585A-1998 inertial technology terms the main performance test methods GJB1801-1993 inertial technology test equipment JJF1156-2006 shock and vibration speed measurement terms and definitions should pay attention to the use of this procedure by using the currently valid version of the documents cited.
3 Terms
3.1 centrifuge rotational axis axisofcentrifugerotation Rotation around the axis centrifuge straight.
3.2 Average centrifuge rotation axis axisaveragelineofcentrifuge Geometric centerline axis of rotation of the centrifuge.
3.3 Static working radius in the stationary state, an average of centrifuge rotation axis accelerometer to detect the distance to the center of mass.
3.4 working radius dynamic variation dynamicchangeofworkingradius in operation, the amount of change in a relatively static working radius of the centrifuge.
3.5 Static pitch misalignment angle staticpitchmisalignment A stationary state within the test accelerometer input shaft in the vertical plane relative to the direction of the radius of the centrifuge work Declination.
3.6 static azimuth misalignment angle staticazimuthmisalignment Stationary state accredited declination accelerometer input shaft in a horizontal plane relative to the radial direction of the centrifuge work.
3.7 vertical spindle error plumberrorofmainaxis Average centrifuge rotational axis of the local plumb line deviation angle.
3.8 unbalanced shaking error swayerrorfromunbalance Spindle radial and angular displacements centrifuge rotating body due to their own unbalance.
3.9 Gravity Field calibration device cablibitionequipmentingravity Use as a standard component of the acceleration of gravity accelerometer bias calibration value, scale factor and other performance parameters Means.
4 Overview
4.1 The principle and structure
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 23 pages — is available in the English PDF.
How to Download JJG 1066-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
Secure payment via Stripe
Payments accepted
JJG 1066-2011
$465.00