JJG 1037-2008Verification Regulation of turbine Flowmeter (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (18 pages)

Need quotation for your management?

Get a formal quotation for JJG 1037-2008 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Ver

Level / Type

National · Mandatory

Issue date

March 25, 2008

Implementation date

June 25, 2008

Scope

JJG 1037-2008 (Verification Regulation of turbine Flowmeter) is available as an English-translated PDF.

JJG 1037-2008 is the Chinese standard "Verification Regulation of turbine Flowmeter". Its scope clause reads: This Regulation applies to the type evaluation, initial verification and subsequent verification of turbine flowmeters (hereinafter referred to as flowmeters).

Its clauses include references; terms and definitions; metrological instrument control. It was issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Ver on 2008-03-25 and took effect on 2008-06-25.

Found what you need?

Document preview — JJG 1037-2008

National Standard of the People's Republic of China

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Ver

Contents

  • 1 Scope...6
  • 2 References...6
  • 3 Terms and definitions...6
  • 4 General...7
  • 4.1 Working principle...7
  • 4.2 Structure and composition...7
  • 4.3 Signal output mode...7
  • 5 Metrological performance requirements...7
  • 5.1 Accuracy grade...7
  • 5.2 Repeatability...8
  • 6 General technical requirements...8
  • 6.1 Attach files...8
  • 6.2 Nameplate and marking...8
  • 6.3 Appearance...9
  • 7 Metrological instrument control...9
  • 7.1 Verification conditions...9
  • 7.2 Verification items and verification method...12
  • 7.3 Processing of verification results...17
  • 7.4 Verification cycle...17
  • Annex A Type evaluation outline...18

1 Scope

This Regulation applies to the type evaluation, initial verification and subsequent verification of turbine flowmeters (hereinafter referred to as flowmeters).

2 References

JJF 1004-2004 Metrological terms and their definitions for flow rate

GB/T 18940-2003/ISO 9951.1993 Measurement of gas flow in closed conduits -

Turbine flowmeters

GB 17820-1999 Natural gas

GB/T 13609-1999 Natural gas - Sampling guidelines

When using this Regulation, it is important to use the current valid version of the above references.

3 Terms and definitions

This Regulation uses the following terms, in addition to the metrological terms and their definitions for flow rate in JJF 1004-2004.

3.1 K-coefficient

The number of pulses per unit volume of the fluid flowing through the flowmeter.

3.2 flow conditioner

A component that reduces vortices and improves velocity distribution.

3.3 transitional flow-rate qt

The flow value between the maximum flow and the minimum flow, which divides the flow range into two different zones of the maximum allowable error, namely “high zone” and “low zone”.

d. Sign and number of license of manufacturing metrological instruments;

e. Nominal pressure;

f. Applicable working pressure and working temperature range;

g. Flow range;

h. Accuracy grade;

i. Date of manufacture.

As well as other relevant technical indicators.

6.3 Appearance

6.3.1 The newly manufactured flowmeter shall have a good surface treatment, and shall not have burrs, scratches, cracks, rusts, mildews and coating peelings. The interior of the flowmeter shall be clean, and the turbine rotor shall rotate flexibly. The seal surface shall be smooth and no damage.

6.3.2 The welding of the connection part of the flowmeter surface shall be flat and smooth, no faulty soldering, desoldering, etc.

6.3.3 The connectors must be solid and reliable, and shall not be loose or fall off due to vibration.

6.3.4 The indicated figures shall be striking, neat, and the characters and symbols that represent the function shall be complete, clear and correct.

6.3.5 The button shall have moderate hand-fell and no adhesion phenomenon.

6.3.6 Each mark of the flowmeter shall be correct; the protective glass on the reading device shall have a good transparency and no defects such as distortion of the reading that obstruct reading.

7 Metrological instrument control

The metrological instrument control includes type evaluation, initial verification and subsequent verification. “Type evaluation outline” is given in Annex A.

7.1 Verification conditions

7.1.1 Flow standard device
7.1.1.1 The flow standard device (hereinafter referred to as device) and its supporting

instruments shall have a valid verification certificate.

temperature.

(2) During the verification of each flow point, the liquid temperature variation shall not exceed ± 0.5 °C.

(3) The liquid shall not be mixed with gas; if necessary, a getter can be installed on the upstream of the flowmeter.

7.1.2.3 Gas for verification

(1) The gas shall be free of free water or oil and other impurities.

(2) If using air as a verification medium, under any conditions, the condensation caused by water vapor in air shall not appear.

(3) If using the natural gas as a verification medium, the gas component shall be relatively stable, complying with the requirements of Type 2 gas in GB 17820.

The sampling is carried out according to GB/T 13609.

(4) During each verification of each flow point, the temperature variation of the gas for verification shall not exceed ± 0.5 °C.

(5) During each verification of each flow point, the pressure variation of the gas for verification shall not exceed ± 0.5 %.

7.1.3 Environmental conditions of verification

7.1.3.1 The ambient temperature is (5 ~ 45) °C; the relative humidity is generally 15 %

~ 95 %; the atmospheric pressure is generally (70 ~ 106) kPa.

7.1.3.2 The AC supply voltage shall be (220 ± 22) V, the power supply frequency shall be (50 ± 2.5) Hz, or use a suitable AC or DC power supply (e.g. 24 V DC power supply) according to the requirements of the flowmeter.

7.1.3.3 The effect of the external magnetic field on the flowmeter shall be small enough to be negligible.

7.1.3.4 The effect of the mechanical vibration and noise on the flowmeter shall be small enough to be negligible.

7.1.4 Flowmeter under verification

7.1.4.1 The flowmeter shall be coaxially installed with the front and rear straight pipe sections, and the connection part of the test pipe section shall be free from leakage.

The gasket at the connection shall not penetrate into the fluid pipe.

7.1.4.2 When measuring the temperature of the fluid flowing through the flowmeter, it

according to the method specified in the flowmeter instructions.

7.2.3.2 The flowmeter shall be operated for at least 5 min in the range of 70 % to 100 % of the achievable maximum verification flow, and be verified after the fluid temperature, pressure and flow are stabilized.

7.2.3.3 Flowmeter verification

(1) The verification of the flowmeter shall contain the following flow points. qmin, qt,

0.40 qmax and qmax; for flowmeters with an accuracy grade of more than 0.5 %, add the flow points of 0.25 qmax and 0.70 qmax; for flowmeters with an accuracy grade of more than 0.5 % and a measuring range ratio of greater than 20 . 1, add a verification point, of which the flow is 0.1 qmax.

(2) During the verification, whenever a flow point is adjusted, the verification shall be carried out afte...

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.

How to Download JJG 1037-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
18 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 1037-2008

$125.00