Valid

JJG 1017-2007Verification Regulation of Standard Hydrophones in the Frequency Range 1 kHz~1 MHz (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (18 pages)

Need quotation for your management?

Get a formal quotation for JJG 1017-2007 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

February 28, 2007

Implementation date

May 28, 2007

Scope

JJG 1017-2007 (Verification Regulation of Standard Hydrophones in the Frequency Range 1 kHz~1 MHz) is available as an English-translated PDF.

JJG 1017-2007 — This standard applies to the frequency range of 1kHz ~ 1MHz standard hydrophone initial verification, testing and use of follow-up inspection.

Found what you need?

Document preview — JJG 1017-2007

National Standard of the People's Republic of China

ICS
17.140
Classification
A 59

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • 1 Scope (1)
  • 2. Referenced Documents (1)
  • 3 Terminology and units of measurement (1)
  • 3.1 Reciprocal transducers electric terminal (1)
  • 3.2 Transducer for electrical transfer impedance (1)
  • 3.3 Electrical transfer impedance mode (2)
  • 3.4 Open circuit voltage hydrophone (2)
  • 3.5 Reference Center (2)
  • 4 Overview (2)
  • 5 Metering performance requirements (2)
  • 5.1 Free field [voltage] Sensitivity [level] (2)
  • 5.2 Free-field frequency response sensitivity level (2)
  • 6 General Requirements (2)
  • 6.1 Appearance structure (2)
  • 6.2 Adaptability of work (2)
  • 6.3 Of the work (3)
  • 6.4 Mark and factory calibration data (3)
  • 7 Control of measuring instruments (3)
  • 7.1 Test conditions (3)
  • 7.2 Verification Project (4)
  • 7.3 Verification Methods (5)
  • 7.4 Test results processing (10)
  • 7.5 Test cycle (10)
  • Appendix A Pulse sound calibration technology (11)

1 Scope (1)

2 Referenced Documents (1)

3 Terminology and units of measurement (1)

3.1 Reciprocal transducers electric terminal (1)

3.2 Transducer for electrical transfer impedance (1)

3.3 Electrical transfer impedance mode (2)

3.4 Open circuit voltage hydrophone (2)

3.5 Reference Center (2)

4 Overview (2)

5 Metering performance requirements (2)

5.1 Free field [voltage] Sensitivity [level] (2)

5.2 Free-field frequency response sensitivity level (2)

6 General Requirements (2)

6.1 Appearance structure (2)

6.2 Adaptability of work (2)

6.3 of the work (3)

6.4 Mark and factory calibration data (3)

7 Control of measuring instruments (3)

7.1 Test conditions (3)

7.2 Verification Project (4)

7.3 Verification Methods (5)

7.4 Test results processing (10)

7.5 Test cycle (10)

Appendix A pulse sound calibration technology (11)

Mutual authentication (13) The Method of test conditions to Appendix B Appendix C electric load correction (15) Appendix D calibration certificate and test results of notice-page format (16) Measurement Uncertainty Appendix E Examples (18) 1kHz ~ 1MHz hydrophone standard test procedures the regulations refer to the International Electrotechnical Commission IEC 60565Ed.2.2006 "underwater acoustic hydrophone 0.01Hz ~ 1MHz frequency range calibration "in the free-field reciprocity calibration method.

1 Scope

The order applies to frequencies within the range of 1kHz ~ 1MHz initial verification standard hydrophone, and make follow-up test with the test. Within the frequency range of the transmitter to transmit the current response standard level calibration can also be implemented by reference.

2 Citations

The regulations cited in the following documents.

GB/T 3102.7-1993 "acoustic volume and unit" GB/T 3223-1994 "acoustic underwater acoustic transducer free-field calibration method" GB/T 3947-1996 "Acoustics terminology" GB/T 4128-1995 "Acoustics Standard hydrophone" GJB1727-1993 "IF a standard hydrophone test procedures" JJF1001-1998 "common measurement terms and definitions" JJF1034-2005 "Acoustic measurement terminology and definitions" JJF1059-1999 "Measurement Uncertainty and indicates" IEC 60565Ed.2.2006, Underwateracoustics-hydrophones-calibrationinthefrequency range0.01Hzto1MHz when using this procedure, it should pay attention to using the currently valid version of the documents cited.

3 terminology and units of measurement the procedure adopted GB/T 3947-1996, JJF1001-1998, JJF1034-2005 regarding terms and definitions.

This procedure uses quantities and units GB/T 3102.7-1993 prescribed.

In the present statutes, if not explained, all the voltage, current, sound pressure refers to a valid value.

3.1 reciprocal transducers electric terminal (electricalterminalsofareciprocaltransducer) Measuring the electrical terminals of the emission current measured open circuit voltage of the electric terminal as a transmitter and is used as a hydrophone.

Note. If the transducer is immersed in water, the lowest electrical impedance between the end of the water is known as "low", and the other end is called the "high end." 3.2 transducer for electrical transfer impedance (electricaltransferimpedanceofatransducerpair) when the transmitter and hydrophone placed in the free sound field, its axis in a straight line and on time for each other, both ends of the hydrophone Open instantaneous voltage and instantaneous current through the emitter complex than that.

Unit. ohm, ohm.

Note.

1. Electrical transfer impedance is complex.

2. Due to the transfer of electrical impedance of the sound field conditions, the transmitter and the hydrophone electrical load, and therefore, together with the relevant conditions and electrical voltage Measuring end of the stream should be noted.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.

How to Download JJG 1017-2007

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
18 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 1017-2007

$345.00