JJG 1013-2006Verification Regulation of γ Radiation Source Used in Head Stereotactic Radiosurgery Therapy (English PDF)
This is a limited preview
Buy now to download the full PDF (54 pages)
Need quotation for your management?
Get a formal quotation for JJG 1013-2006 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
December 8, 2006
Implementation date
March 8, 2007
Scope
JJG 1013-2006 (Verification Regulation of γ Radiation Source Used in Head Stereotactic Radiosurgery Therapy) is available as an English-translated PDF.
JJG 1013-2006 — This standard applies to the head stereotactic radiosurgery γ radiation treatment source initial verification, testing and use of follow-up inspection.
Found what you need?
Document preview — JJG 1013-2006
National Standard of the People's Republic of China
- ICS
- 17.240
- Classification
- A 58
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- 1 Scope (1)
- 2 Citations (1)
- 3 Terms and units of measurement (1)
- 3.1 Terminology (1)
- 3.2 Unit of measurement (2)
- 4 Overview (2)
- 5 Metrological performance requirements (2)
- 5.1 Radiation isocenter and mechanical isocenter consistency (2)
- 5.2 "Superimposed radiation field" (2)
- 5.3 "Superimposed penumbra" (3)
- 5.4 Head gamma knife output dose (3)
- 6 General technical requirements (3)
- 6.1 Equipment Labels (3)
- 6.2 Device Display (3)
- 6.3 Safety requirements for treatment equipment (3)
- 7 Measuring instrument control (4)
- 7.1 Verification conditions (4)
- 7.2 Verification items and verification methods (6)
- 7.3 Processing of verification results (7)
- 7.4 Verification cycle (8)
- Appendix A Calculation Formula for Focus Absorbed Dose (9)
- Appendix B Evaluation of gamma-knife focus dose measurement uncertainty (10)
- Appendix C Verification certificate page format (11)
- Appendix D Head gamma knife experiment report (1) (13)
- Appendix E Head gamma knife experiment report (2) (15)
1 Scope (1)
2 Citations (1)
3 Terms and units of measurement (1)
3.1 Terminology (1)
3.2 Unit of measurement (2)
4 Overview (2)
5 Metrological performance requirements (2)
5.1 Radiation isocenter and mechanical isocenter consistency (2)
5.2 "Superimposed radiation field" (2) 5.3 "Superimposed penumbra" (3)
5.4 Head gamma knife output dose (3)
6 General technical requirements (3)
6.1 Equipment Labels (3)
6.2 Device Display (3)
6.3 Safety requirements for treatment equipment (3)
7 Measuring instrument control (4)
7.1 Verification conditions (4)
7.2 Verification items and verification methods (6)
7.3 Processing of verification results (7)
7.4 Verification cycle (8)
Appendix A Calculation Formula for Focus Absorbed Dose (9)
Appendix B Evaluation of gamma-knife focus dose measurement uncertainty (10)
Appendix C Verification certificate page format (11)
Appendix D Head gamma knife experiment report (1) (13)
Appendix E Head gamma knife experiment report (2) (15)
Head stereotactic radiosurgery gamma radiation treatment source verification procedure
1 Scope
This procedure is applicable to the first verification, subsequent verification and use of gamma radiation therapy sources for stereotactic radiosurgery of the head.
test.
2 Citations
STEREOTACTICRADIOSURGERYSYSTEM , ReportofTaskGroup42Radiation TherapyCommittee.AAPMREPORTNo.54, June1995 [" Stereotactic radiosurgery system, put Report of the 42nd Working Group of the Radiation Therapy Committee, Technical Report of the American Association of Medical Physicists (AAPM) No. 54 (1995 edition)] Absorbeddosedeterminationinphotonandelectronbeams,Aninternationalcodeof Practice,SecondEdition,IAEATech.Rer.Ser.No.277,VIENNA1997 [Photon and Electronics Absorbed dose measurement of bundles, International Practical Regulations, IAEA Technical Report No. 277 (Second Edition, 1997)] JJF1001-1998 General Terms and Definitions JJF1059-1999 "Measurement and Expression of Measurement Uncertainty" JJG 912-1996 "Regulations for the verification of therapeutic level ionization chamber dosimeter" GB 191-90 "Package Storage and Transportation Graphic Mark" GB 4076-83 "General provisions for sealed radioactive sources" GB 5013.1-1997 "Rubber insulated flexible cable with rated voltage of 450/750V and below - Part 1. 1 General regulation GB 9706.1-1995 "Medical Electrical Equipment Part 1. General Requirements for Safety" GB/T 9969.1-1998 "General rules for the use of industrial products" GB/T 14710-93 "Environmental requirements and experimental methods for medical electrical equipment" YY0076-92 "Lamination classification and technical conditions of metal parts" YY0096-92 "Cobalt-60 Teletherapy Machine" GB/T 17857-1999 "Medical radiology terms (radiation therapy, nuclear medicine and radiation dosimetry equipment)" 3 terms and units of measure
3.1 Terminology
3.1.1 Collimator colimator A device that limits the direction of the beam and the size of the beam.
3.1.2 Focus Focus
The center of the beam that is focused by the collimator is called the focus.
3.1.3 "Overlay radiation field" size "overlapingofirradiationfield" size a three-dimensional "superimposed radiation field" composed of a plurality of radiation sources arranged in a certain latitude and longitude, with a dose
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 54 pages — is available in the English PDF.
How to Download JJG 1013-2006
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1201-2024 — Digital Tyre Pressure Gauges
JJG 1202-2024 — Long Distance Transmissible Pressure Gauges
JJG 746-2024 — Ultrasonic Flaw Detectors
Secure payment via Stripe
Payments accepted
JJG 1013-2006