Scope

JJG 0061-2001 is the English-translated version of 涡流探伤仪.

JJG 0061-2001 is the Chinese standard "[JJG(MH) 0061-2001] Verification Regulation of Eddy Current Flaw Detector". Its scope clause reads: This Regulation is applicable to the initial verification, subsequent verification and in- use inspection of the probe coil eddy current flaw detector (hereinafter referred to as the eddy current instrument).

The verification of other types of eddy current instruments can refer to this Regulation. Its clauses include summary; requirements for metrological properties; general technical requirements.

Found what you need?

Document preview — JJG 0061-2001

National Standard of the People's Republic of China

Issued by: General Administration of Civil Aviation of China

Contents

  • 1 Scope4
  • 2 Normative References4
  • 3 Summary4
  • 4 Requirements for Metrological Properties4
  • 4.1 Excitation source4
  • 4.2 Sensitivity5
  • 4.3 Signal-to-noise ratio5
  • 4.4 Lift-off effect5
  • 4.5 Edge effect5
  • 4.6 Tilt performance6
  • 5 General Technical Requirements6
  • 5.1 Appearance requirements6
  • 5.2 The entire machine function6
  • 5.3 Display unit6
  • 5.4 Alarm performance7
  • 5.5 Technical documents and attachments7
  • 6 Metrological Instrument Control7
  • 6.1 Verification conditions7
  • 6.2 Verification items and verification methods8
  • 6.3 Processing of verification results14
  • 6.4 Verification cycle14
  • Appendix A Standard Specimen15
  • Appendix B Verification Certificate Format16
  • Appendix C Verification Rejection Notice Format18
  • Appendix D Verification Record Format19

1 Scope

This Regulation is applicable to the initial verification, subsequent verification and in- use inspection of the probe coil eddy current flaw detector (hereinafter referred to as the eddy current instrument). The verification of other types of eddy current instruments can refer to this Regulation.

2 Normative References

JJF 1001-1998 General Terms in Metrology and Their Definitions

JJF 1002-1998 The Rules for Drafting National Metrological Verification

Regulation

GB/T 12604.6-1990 Terminology for Nondestructive Testing - Eddy Current Testing

MH/T 3002.5-1997 Nondestructive Testing in Aircraft - Eddy Current Testing

When using this Regulation, care shall be taken to use the currently valid versions of the above cited documents.

3 Summary

The eddy current instrument is an electronic device that uses the principle of electromagnetic induction to perform non-destructive testing of metal materials and their finished parts, and is widely used in civil aircraft maintenance and inspection.

The eddy current instrument is mainly composed of a power supply, an oscillator, a phase sensitive detector, a phase shifter, an amplifier and a display.

4 Requirements for Metrological Properties

4.1 Excitation source

4.1.1 Output frequency error*f <=±10%;

4.6 Tilt performance

4.6.1 Change the angle between the axis of the probe coil and the normal of the specimen surface from 0° (vertical) to 20°. At this time, the amount of change displayed by the eddy current instrument shall be no greater than 10% of the full scale.

4.6.2 Keep the probe inclined at an angle of 20°; sweep the 0.5mm-deep artificial defect on the standard specimen; and the amount of change displayed by the eddy current instrument shall be no less than 70% of the amount of change displayed in the vertical state.

5 General Technical Requirements

5.1 Appearance requirements

5.1.1 The appearance of the tested eddy current instrument shall be intact; all parts shall be firm and reliable; the knobs shall be positioned accurately; the adjustment shall be smooth; the switch contact shall be good; the operation shall be flexible; and there shall be no mechanical damage that affects the operation.

5.1.2 The scale of the display panel is clear and there is no trace of damage.

5.2 The entire machine function

5.2.1 Place the tested eddy current instrument in the verification environment for 30min.

5.2.2 Check the battery voltage. If the battery voltage does not meet the requirements of the instructions, charge it first.

5.2.3 Connect the standard probe and matching device with the probe cable to the eddy current instrument to form an eddy current inspection system.

5.2.4 Turn on the power of the eddy current instrument, the instrument shall be able to enter the normal working state, and the display shall be normal. Keep the power on and allow the instrument to warm up for 15 min~20 min.

5.2.5 Adjust each function knob (button) one by one, each function of the eddy current instrument shall be able to change accordingly, indicating normal.

5.3 Display unit

Press the balance button, and the pointer (bright spot) on the display panel shall return to the balance point.

6.1.2.4 Standard specimen (see Appendix A).

Standard specimens include aluminum specimens and steel specimens; and steel specimens are suitable for verifying the "Fe" gear of the eddy current instrument.

6.1.3 Supporting equipment.

6.1.3.1 Standard probe.

It has passed the comprehensive performance inspection, is not worn and damaged, and can be matched with the eddy current instrument.

6.1.3.2 Load resistance (R).

The rated resistance and non-inductive resistance specified by the manufacturer can also use standard probes.

6.1.3.3 Low temperature test cabinet.

The size can store the eddy current instrument, the temperature shall be controlled at

0°C±5°C, with a temperature display, to ensure that the instrument is verified in a low temperature state.

6.1.3.4 High temperature test chamber.

The size can store the eddy current instrument, the temperature shall be controlled at

40°C±5°C, with a temperature display, to ensure that the instrument is verified under high temperature conditions.

6.1.3.5 Non-conductive materials.

PTFE film or other wear-resistant insulating film with a thickness of 0.05mm~0.10mm and a thickness of 0.15mm can be stacked in multiple layers.

6.2 Verification items and verification methods

6.2.1 The verification items are shown in Table 1.

The comprehensive performance verification of the eddy current instrument is to connect a standard probe to the eddy current instrument; make the standard probe move at a normal and uniform speed; and keep a certain angle between the probe coil axis and the sample surface. And move on the standard specimen according to the set trajectory; so that verify the sensitivity, signal-to-noise ratio, lift-off effect, edge effect and tilt performance of the eddy current instrument.

In the following verification, for the eddy current meter with variable frequency, shall select the high, medium and low points in the usual frequency range for verification respectively. For the eddy current meter with fixed frequency, the commonly used gears (Fe, NFe) shall be verified, respectively. But for frequency points exceeding

3MHz, the 6.2.7.1d) and 6.2.7.5 verification items shall not be required.

When reading the amount of change displayed by the eddy current instrument, for the instrument displayed on the impedance plane, the vertical component shall be read.

6.2.7.1 Sensitivity verification.

a) Place the probe on the part of the standard specimen without artificial defects (i.e.: the specimen substrate); keep the probe coil axis perpendicular to the specimen surface; and the distance between the center of the coil and the edge of the specimen and artificial defects is no less than 10mm. Set the frequency and phase of the eddy current instrument; adjust the gain of the eddy current instrument to the maximum. If the electrical noise is too large at this time, the gain shall be appropriately reduced until no obvious electrical noise appears.

b) Reduce the gain by 6dB. The instrument displayed on the impedance plane shall adjust the phase; adjust the lift-off signal to the horizontal direction; adjust the instrument; move the probe at a normal speed to sweep the 0.5mm deep artificial defect on the specimen; and record the amount of change Hi (i = 1, 2, 3); measure

3 times; take the average value of H and fill it in Table D6 of Appendix D.

c) For the eddy current instrument whose gain cannot be adjusted quantitatively, after adjusting the instrument according to a), move the probe at a normal speed to scan the 0.2mm deep artificial defect on the standard specimen; and record the amount of change displayed by the eddy current instrument Hi (i = 1, 2, 3);

measure 3 times; take the average value of H and fill it in Table D6 of Appendix

D.

d) Put a layer of insulating material of 0.15mm between the standard specimen and the probe; re-adjust the instrument; repeat the verification of a), b), and c) above.

Record the amount of change Yi (i =1, 2, 3) displayed by the eddy current instrument when the insulating material is filled; measure 3 times; take the average value of Y and fill it in Table D6 of Appendix D.

e) Calculate the ratio of H to Y and fill it in Table D6 of Appendix D.

in 6.2.7.1 and fill it in Table D10 of Appendix D.

6.2.7.6 Alarm performance inspection.

a) In the state of 6.2.7.1a), adjust the gain of the eddy current instrument to make the sensitivity meet the requirements of 4.2.1 or 4.2.2; and adjust the alarm threshold to be lower than 5% of the displayed value of the instrument when the probe scans through the artificial defect; and then move the probe at a normal speed to scan the artificial defects on the standard specimen; and the alarm light and sound shall give an alarm.

b) Change the alarm threshold to be higher than 5% of the value displayed by the instrument when the probe scans through the artificial defect; and then move the probe at a normal speed to scan the artificial defect on the standard specimen.

The alarm light and sound shall not give an alarm; fill the inspection results in the

Table D1 of Appendix D.

6.2.7.7 Low temperature test.

After placing the eddy current instrument in a low temperature test chamber at

0°C±5°C for 30min; repeat the operation in 6.2.7.1; fill in the results in Table D6 of

Appendix D.

6.2.7.8 High temperature test.

After placing the eddy current instrument in a high temperature test chamber at

40°C±5°C for 30min; repeat the operation in 6.2.7.1; fill in the results in Table D6 of

Appendix D.

6.3 Processing of verification results

The eddy current instrument that has passed the verification shall be issued with a certificate of qualification; the unqualified eddy current instrument shall be issued a notice of unqualified verification, and the unqualified items shall be indicated.

6.4 Verification cycle

The verification period of the eddy current instrument can be determined according to the specific usage, but the longest period shall not exceed 12 months.

Chinese Standards

This is an excerpt of the PDF (Some pages are marked off intentionally)

Full-copy PDF can be purchased from 1 of 2 websites:

nu SEARCH the standard ID, such as GB 4943.1-2022.

nu Select your country (currency), for example: USA (USD); Germany (Euro).

nu Full-copy of PDF (text-editable, true-PDF) can be downloaded in 9 seconds.

nu Tax invoice can be downloaded in 9 seconds.

nu Receiving emails in 9 seconds (with download links).

nu SEARCH the standard ID, such as GB 4943.1-2022.

nu Full-copy of PDF (text-editable, true-PDF) can be downloaded in 9 seconds.

nu Receiving emails in 9 seconds (with PDFs attached, invoice and download links).

Translated by: Field Test Asia Pte. Ltd. (Incorporated & taxed in Singapore. Tax ID: 201302277C)

Linkin: https://www.linkedin.com/in/waynezhengwenrui/

------ The End ------

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 22 pages — is available in the English PDF.

Referenced standards

How to Download JJG 0061-2001

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
22 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 0061-2001

$345.00