JJF 1396-2013Calibration specification for spectrum analyzer (English PDF)
This is a limited preview
Buy now to download the full PDF (59 pages)
Need quotation for your management?
Get a formal quotation for JJF 1396-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Level / Type
National · Mandatory
Issue date
February 16, 2013
Implementation date
August 16, 2013
Scope
JJF 1396-2013 (Calibration specification for spectrum analyzer) is available as an English-translated PDF.
JJF 1396-2013 is the Chinese standard "Calibration specification for spectrum analyzer". Its scope clause reads: This specification applies to the calibration of a spectrum analyzer in the frequency range from 3 Hz ~ 50 GHz.
Its clauses include overview; metrological characteristics. It was issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on 2013-02-16 and took effect on 2013-08-16.
Found what you need?
Document preview — JJF 1396-2013
National Standard of the People's Republic of China
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Contents
- Introduction...6
- 1 Scope...7
- 2 Normative references...7
- 3 Overview...7
- 4 Metrological characteristics...7
- 4.1 Reference frequency...7
- 4.2 Calibration signal level...7
- 4.3 Frequency marker...8
- 4.4 Sweep width...8
- 4.5 Resolution bandwidth...8
- 4.6 Frequency stability...8
- 4.7 Vertical display scale...8
- 4.8 Reference level...9
- 4.9 Input attenuator conversion effects...9
- 4.10 Resolution bandwidth conversion effect...9
- 4.11 Display average noise level...9
- 4.12 Residual response...9
- 4.13 Image response...9
- 4.14 Scan time...9
- 4.15 Absolute amplitude...9
- 4.16 Input frequency response...10
- 4.17 Second harmonic distortion...10
- 4.18 Third-order intermodulation distortion...10
- 4.19 Gain compression...10
- 4.20 Input voltage standing wave ratio...10
- 4.21 Power bandwidth...10
- 5 Calibration conditions...10
- 5.1 Environmental conditions...10
- 5.2 Equipment used for calibration...11
- 6 Calibration items and calibration methods...12
- 6.1 Appearance and operation normality inspection...13
- 6.2 Reference frequency...13
- 6.3 Calibration signal level...14
- 6.4 Frequency reading...16
- 6.5 Sweep width...16
- 6.6 Resolution bandwidth...17
- 6.7 Noise sideband...20
- 6.8 Residual frequency modulation...21
- 6.9 Vertical display scale...22
- 6.10 Reference level...24
- 6.11 Input attenuator conversion effect...24
- 6.12 Resolution bandwidth conversion effect...25
- 6.13 Display average noise level...26
- 6.14 Residual response...27
- 6.15 Image response...27
- 6.16 Scan time...28
- 6.17 Absolute amplitude...29
- 6.18 Input frequency response...30
- 6.19 Second harmonic distortion...31
- 6.20 Third-order intermodulation distortion...32
- 6.21 Gain compression...33
- 6.22 Input voltage standing wave ratio...34
- 6.23 Frequency counting...34
- 6.24 Power bandwidth...35
- 7 Presentation of calibration results...35
- 8 Recalibration Interval...36
- Appendix A Calibration record form...37
- Appendix B The inner page format of calibration certificate...47
- Appendix C Examples of measurement uncertainty evaluation...59
1 Scope
This specification applies to the calibration of a spectrum analyzer in the frequency range from 3 Hz ~ 50 GHz.
2 Normative references
This specification refers to the following documents.
JJF 1071-2010 The rules for drafting national calibration specification
For the dated documents, only the versions with the dates indicated are applicable to this specification; for the undated documents, only the latest version (including all the amendments) are applicable to this specification.
3 Overview
Spectrum analyzer is a super-heterodyne receiver with display device. It consists of preselector, scanning local oscillator, mixer, middle amplifier, filter, detector, amplifier and display. It is mainly used for spectrum analysis, AND can also be used for the measurement of frequency, level, gain, attenuation, analog modulation and digital modulation, and distortion jitter, which is and indispensable instrument in communication, radio, television, radar, aerospace, and other technology areas.
4 Metrological characteristics
4.1 Reference frequency
Frequency nominal value. 10 MHz;
Frequency accuracy. 1 × 10-5 ~ 1 × 10-10.
4.2 Calibration signal level
Level range. -30 dBm ~ 0 dBm;
4.16 Input frequency response
Frequency range. 3 Hz ~ 50 GHz;
Frequency response. ± 0.2 dB ~ ± 5 dB.
4.17 Second harmonic distortion
Frequency range. 10 MHz ~ 25 GHz.
4.18 Third-order intermodulation distortion
Frequency range. 10 MHz ~ 50 GHz.
4.19 Gain compression
Frequency range. 10 MHz ~ 50 GHz.
4.20 Input voltage standing wave ratio
Frequency range. 10 MHz ~ 50 GHz;
Input voltage standing wave ratio. 1.02 ~ 3.
4.21 Power bandwidth
3dB bandwidth range. 1 Hz ~ 10 MHz;
The maximum allowable error. ± 0.02 dB ~ ± 0.50 dB.
Note. The above lists the measurement range and technical parameter requirements of each calibration parameter of the spectrum analyzer; during calibration, it shall follow the technical parameter requirements as...
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 59 pages — is available in the English PDF.
Referenced standards
Normative references
How to Download JJF 1396-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 1071-2010 — The rules for drafting national calibration specification
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1064-2024 — Calibration Specification for Coordinate Measuring Machines
Secure payment via Stripe
Payments accepted
JJF 1396-2013
$135.00