JJF 1107-2003Calibration Specification of Infrared Thermometers for Measurement of Human Temperature (English PDF)

Preview PDF

Also coversJJF1107-2003

This is a limited preview

Buy now to download the full PDF (16 pages)

Need quotation for your management?

Get a formal quotation for JJF 1107-2003 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

June 19, 2003

Implementation date

June 29, 2003

Scope

JJF 1107-2003 (Calibration Specification of Infrared Thermometers for Measurement of Human Temperature) is available as an English-translated PDF.

JJF 1107-2003 is the Chinese standard "Calibration Specification of Infrared Thermometers for Measurement of Human Temperature".

Its scope clause reads: This Specification is applicable to calibration of infrared thermometers for measurement of human temperature and infrared quick screening instruments for measurement of human body surface temperature.

Its clauses include terms and units of measurement; overview; metering characteristics; calibration conditions; calibration items and calibration methods; expression of calibration results; recalibration interval.

It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on 2003-06-19 and took effect on 2003-06-29.

Found what you need?

Document preview — JJF 1107-2003

National Standard of the People's Republic of China

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • 1 Scope...5
  • 2 Normative references...5
  • 3 Terms and units of measurement...5
  • 4 Overview...7
  • 5 Metering characteristics...7
  • 6 Calibration conditions...9
  • 7 Calibration items and calibration methods...11
  • 8 Expression of calibration results...14
  • 9 Recalibration interval...15
  • Annex A Evaluation on calibration uncertainty of infrared thermometer...16

1 Scope

This Specification is applicable to calibration of infrared thermometers for measurement of human temperature and infrared quick screening instruments for measurement of human body surface temperature.

2 Normative references

JJF 1001-1998, General Terms in Metrology and Their Definitions

JJF 1007-1987, Temperature Metrological Terms and Their Definitions

JJF 1059-1999, Evaluation and Expression of Uncertainty in Measurement

GB/T 19146-2003, General requirements for infrared devices for instant screening of human skin temperature

EN 12470-5.2003 (E) Clinical thermometers - Part 5.Performance of infrared ear thermometers (with maximum device)

ASTM E 1965-98, Standard Specification for Infrared Thermometers for

Intermittent Determination of Patient Temperature

When using this regulations, the existing valid editions of above quoted standards shall be used.

3 Terms and units of measurement

3.1 Terms

3.1.1 Calibration mode (direct measurement mode)

The display mode for infrared thermometer measurement or calibration. Display the temperature without any correction, that is, the measurement result of the blackbody temperature.

3.1.2 Estimation mode

The display mode for infrared thermometer measurement. Display the estimated temperature after the correction of environmental temperature changes, emissivity, measured body position and other factors.

4 Overview

The infrared thermometer for measuring human body temperature is an instrument for measuring human body temperature by radiation exchange between the probe and the measured object. It includes infrared thermometer designed to measure human body temperature and infrared screening instrument.

5 Metering characteristics

5.1 Display temperature range

In any display mode, the display temperature range of the infrared thermometer shall cover the range specified in Table 1.

5.3 Environmental conditions

The allowable operating environment range for infrared thermometer to meet the laboratory error requirements specified in 5.2 shall cover the provisions in

Table 1.

5.4 Display and interface

5.4.1 Resolution

The display resolution shall meet the requirements of Table 1.

5.4.2 Display mode

5.6.4 Infrared thermometer user manual shall include but not limited to the following.

6 Calibration conditions

6.1 Environmental conditions

The temperature and humidity of the calibration laboratory environment shall meet the requirements of 18°C~28°C, (30~70)% RH and the operating environment conditions of the calibration equipment.

6.2 Standard and other equipment

6.2.1 Blackbody radiation source

The temperature range of the blackbody radiation source shall meet the calibration requirements of the thermometer to be calibrated.

6.2.2 Electrical measuring instruments that measure the analog output of

calibrated thermometer (if required).

6.2.3 Required bracket for calibration thermometer

7 Calibration items and calibration methods

7.1 Calibration items

7.1.1 Appearance inspection

The infrared thermometer and infrared screening instrument shall be in good conditions. Each function is normal and the probe shall be clean. If it uses battery power supply, when the battery power is insufficient, there shall be a low voltage prompt function.

7.1.3 Warning temperature measurement error

The infrared screening instrument looks for the warning temperature value near the preset warning temperature point to determine the warning temperature measurement error.

7.2 Calibration methods

See Table 3 for calibration methods.

7.2.1 Infrared thermometer
7.2.1.1 Repeat the measurement of the blackbody temperature at the set

blackbody temperature specified in Table 3.It can only select part of the blackbody set temperature in Table 3 or select the blackbody set temperature according to user requirements.

7.2.1.6 For laboratory error determination, measure and record the corrected

infrared thermometers ti, j and blackbody temperature tBBi (if blackbody is traceable to the radiation temperature, it shall be converted to the radiation temperature) at the nominal set temperature tsi of each black body. Determine laboratory error for each measurement. The laboratory error ei, j is defined as.

Where, tBBi is the blackbody temperature; ti, j is the jth temperature reading when the calibrated thermometer measures the blackbody temperature tBBi in the calibration mode; j indicates the order of readings.

7.2.2 Infrared screening instrument
7.2.2.1 Preheat the infrared screening instrument according to the time

specified in the user manual.

8 Expression of calibration results

Calibration results shall be reflected on the calibration certificate or calibration report.

9 Recalibration interval

The recommended interval for recalibration is 1 year. It shall be appropriately shortened when it is used frequently.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.

Referenced standards

How to Download JJF 1107-2003

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
16 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1107-2003

$120.00