JG/T 211-2007Field test method of air permeability, watertightness, wind load resistance performance for exterior windows (English PDF)
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for JG/T 211-2007 in 30 minutes.
Issued by
Ministry of Construction of the People's Republic of China
Level / Type
National · Recommended
Issue date
August 21, 2007
Implementation date
January 1, 2008
Scope
JG/T 211-2007 (Field test method of air permeability, watertightness, wind load resistance performance for exterior windows) is available as an English-translated PDF.
JG/T 211-2007 — This standard specifies the performance evaluation and classification of on-site testing methods of airtight, watertight and wind pressure resistant exterior windows, on-site testing, knot Fruit assessment, test report.
This standard applies to the installation of the building outside the window airtight, watertight and wind pressure performance on-site testing. Detection of objects except the building outside the window itself it may also include its installation connection.
Outside the building can refer to this standard. This standard does not apply to the type of building exterior window product testing.
Found what you need?
Document preview — JG/T 211-2007
National Standard of the People's Republic of China
- ICS
- 91.060.01
- Classification
- Q 70
Issued by: Ministry of Construction of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Performance evaluation and grading
- 5.1 Detection principle and device
Foreword
The main relationship between this standard and GB/T 7106-2002, GB/T 7107-2002, GB/T 7108-2002 are as follows.
1. Detection principle, the same index of performance grade specimens.
2. The test object is different, this standard refers to the test object has been installed in the outer wall of the building windows and installation of the connection site.
3. Affected by the outdoor environment and assessment methods are different.
This standard is proposed by the Ministry of Construction standard quota research institute.
This standard by the Ministry of Construction Building Products and Components Products Standardization Technical Committee.
Introduction
The standard anti-wind pressure detection safety detection pressure (P'3) is selected as the project, that is not detected P'3 detection, the use of 2.5 times P1 Grading and type testing or design verification test results contrast judgment; when needed, P'3 detection, P'3 detection is completed and re-enter Perform airtight and watertight tests and make any necessary repairs or replacements based on the test results. This is mainly for the following reasons.
1. Field testing is different from laboratory testing, the test is completed after the majority of windows to be continued to use, and the results of the previous test showed P'3 it is possible to reduce the air tightness and watertightness of the outer window.
2. P'3 is the safety detection value, which corresponds to the wind load 50 years after the design reproduction period; P1 is the wind load of the deformation detection value, Like should not occur damage or decline in function.
3. The relationship P3 = 2.5P1 only for the elastic deformation of the established, and hardware, glass, etc. may not be applicable.
Outside the building airtight, watertight, wind pressure performance on-site testing methods
1 Scope
This standard specifies the performance evaluation and classification of on-site testing methods of airtight, watertight and wind pressure resistant exterior windows, on-site testing, knot Fruit assessment, test report.
This standard applies to the installation of the building outside the window airtight, watertight and wind pressure performance on-site testing. Detection of objects except the building outside the window itself it may also include its installation connection. Outside the building can refer to this standard. This standard does not apply to the type of building exterior window product testing.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. All dated references, which are subsequently owned Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to reach an agreement based on this standard research Whether you can use the latest versions of these files. For undated references, the latest version applies to this standard.
Classification of wind pressure resistance in exterior windows of buildings and methods of testing GB/T 7106-2002 Building exterior windows air tightness classification and testing methods Classification of exterior watertightness of building windows and methods of testing GB/T 7108-2002
3 Terms and definitions
The following terms and definitions apply to this standard.
Construction outside the window frame and wall body and other parts of the connection.
Inspection of the building outside the window and the installation of connections.
4 Performance evaluation and grading
4.1 test object airtight performance. 10Pa pressure difference under the test target unit length of air penetration or air permeability per unit area into Line evaluation, gas tightness grading value should be consistent with the provisions of Table 1 GB/T 7107-2002.
4.2 test object watertight performance. To detect the object to produce a serious leakage pressure differential pressure before the level of evaluation, watertight performance rating should be in line with the provisions of Table 1 GB/T 7108-2002.
4.3 test object wind pressure performance. With the allowable deflection of the rod and test object is damaged or dysfunctional corresponding to Pressure differential assessment, wind pressure performance rating value should be consistent with the provisions of Table 1 of GB/T 7106-2002.
5 on-site testing
5.1 Detection principle and device
5.1.1 site use seal plate, envelope and the outer window to form a static pressure box through the air supply system from the plenum or the plenum to the plenum in the air Detection of both sides of the object to form a positive pressure difference or negative pressure difference. In the plenum leads to the measuring hole to measure the pressure difference, installs on the pipeline the flow measurement device measurement Air infiltration, outside the window to arrange the right amount of nozzle watertight test, the displacement sensor installed in place to measure the deformation of the rod.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
Referenced standards
How to Download JG/T 211-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JG/T 216-2024 — Small unit building curtain wall components
JG/T 236-2022 — Electric heating radiator for space heating
JG/T 302-2022 — Roller shutters
Secure payment via Stripe
Payments accepted
JG/T 211-2007
$105.00