JC/T 1043-2007 — This Standard specifies technical requirements and test methods of lead extraction in faucets. This Standard applies to brass faucets for drinking water installed at the end of water supply pipeline.
Found what you need?
Document preview — JC/T 1043-2007
National Standard of the People's Republic of China
- Classification
- Q 31
Issued by: National Development and Reform Commission of the People’s Republic of China
Contents
- Foreword...3
- 1 Scope...4
- 2 Normative references...4
- 3 Terms and definitions...4
- 4 Requirements...5
- 5 Test Methods...5
Foreword
This Standard references to chapter 9 The Parts Of Mechanical Piping
Equipment of NSF/ANSI 61-2003e "Drinking water system components - Health
effects", the technical requirements and test methods of lead test statistical Q value is
same as this Standard.
This Standard is under the Jurisdiction of National Technical Committee on
Architecture and Sanitary Ceramics of Standardization Administration of China.
This Standard is responsibly drafted by organizations. National Building Material
Industry Hardware and Plumbing Equipment Quality Supervision Test Center, China
Building Ceramics & Sanitary Ware Association, and Sanitary Wares Accessories
Branch of China Building Ceramics & Sanitary Ware Association.
Participating organizations in the draft of this Standard. Guangdong Chaoyang
sanitary Co., Ltd, Joyou Group Co., Ltd, Sunlot Group Co., Ltd, and Fujian Huihuang
Sanitary and Plumbing Group Co., Ltd.
This Standard is mainly drafted by. Shi Hongwei, Xiao Ruifeng, Wang Wei and
Miao Bin.
Limit of lead extraction in faucets
1 Scope
This Standard specifies technical requirements and test methods of lead
extraction in faucets.
This Standard applies to brass faucets for drinking water installed at the end of
water supply pipeline.
2 Normative references
The following normative documents contain provisions which, through reference
in the text, constitute provisions of this Standard. For dated reference, subsequent
amendments or revisions (excluding contents of corrigenda) do not apply. However,
parties who enter into agreement based on this Standard are encouraged to
investigate the possibility of applying the most recent editions of the standards
indicated below. For undated references, the latest edition of the normative document
referred to applies.
GB 5750-1985 Standard examination methods for drinking water
NSF/ANSI 61-2003e System Components Drinking Water - Health Effects
3 Terms and definitions
The following terms and definitions apply to this Standard.
3.1 Cold water volume
Under normal operating conditions, the device connects the supply of hot and
cold water, the cold water volume is the volume (from inlet to outlet) contained in the
part of device usually contacting cold water. This part of volume usually excludes the
water volume of the part of device which only contacts with hot water.
3.2 Cold mix volume adjustment factor (CMV)
The cold water volume of device divided by the entire water volume of device.
V - The volume of chlorine stock solution needed to be added, mL;
B - The volume of extraction water, L;
A - The concentration of chlorine stock solution, mg / mL.
5.2.1.3 0.4 mol/L Sodium bicarbonate solution
DISSOLVE 33.6 g of anhydrous sodium bicarbonate into reagent water, and
DILUTE it with reagent water to 1L, MIX well, PREPARE fresh solution every week.
5.2.2 Preparation of extraction water
TAKE 25 mL of 0.4 mol / L sodium bicarbonate solution (5.2.1.3), the right amount
of chlorine stock solution (5.2 1. 2), USE reagent water to DILUTE it to 1 L, USE 0.1
mol / L hydrochloric acid to adjust the pH value. The solution shall meet the following
requirements. pH. 8 0 ± 0 5, alkalinity. (500 ± 25) mg / L, inorganic carbon. (122 ± 5)
mg / L, chlorine. 2 mg / L.
5.3 Washing
RINSE the sample with water for 15 min, and then WASH it three times with
reagent water, WASH away residue and dirt within the sample.
5.4 Sample Adjustment
At room temperature of (23 ± 2) °C, WASH it with extraction water three times.
Extraction water shall completely fill the sample until the beginning of the extraction,
and the process shall not exceed 72 h.
5.5 Extraction
Extraction shall be conducted at room temperature of (23 ± 2) °C. After
conducting sample adjustment, FILL the sample with extraction water; ENSURE
extraction area is maximum. PLUG tightly both ends of the sample with clean cork
coated with a PTFE film or rubber stopper. EXTRACT it in accordance with extraction
order in Table 1. For example. On the 1st day 8. 00 am FILL extraction water;
REPLACE after 2 h; REPLACE continuously for four times; and COMPLETE the
replacement of water extraction at 16. 00 pm of that day; KEEP for 16 h; on the 2nd
day, REPEAT the same course of the 1st day. REPEAT the same course as the 1st
day on the 3rd day, the 4th day, and the 5th day; and COLLECT the extraction water
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.
Referenced standards
Normative references
GB 5750-1985
How to Download JC/T 1043-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JC/T 2850-2024 — Test method for determining interfacial bonding strength of 3D printed cement-based materials
JC/T 864-2023 — Polymer Emulsion Architectural Waterproof Coating
JC/T 1074-2021 — Purificatory Performance of Coatings with Air Purification
Secure payment via Stripe
Payments accepted
JC/T 1043-2007
$85.00