Valid

JB/T 8734.4-2012Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V - Part 4: Insulated wires for internal wiring of equipment (English PDF)

额定电压450/750V 及以下聚氯乙烯绝缘电缆电线和软线 第4部分:安装用电线

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for JB/T 8734.4-2012 in 30 minutes.

Issued by

MIIT

Level / Type

Industry · Recommended

Issue date

May 24, 2012

Implementation date

November 1, 2012

Scope

JB/T 8734.4-2012 is the English-translated version of 额定电压450/750V 及以下聚氯乙烯绝缘电缆电线和软线 第4部分:安装用电线.

JB/T 8734.4-2012 is the Chinese standard "Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V - Part 4: Insulated wires for internal wiring of equipment".

Its scope clause reads: This Part of JB/T 8734 specifies the operating characteristics, models, specifications, technical requirements and inspection of wires for internal wiring.

This Part applies to copper core polyvinyl chloride insulated wires for internal wiring of electric appliance, instrument, electronic equipment and automation equipment of AC rated voltage U0/U up to and including 300/300V.

Its clauses include operational characteristics; models; structure size inspection; high temperature pressure test; thermal shock test; flame non-propagation test t t t t t t gb/t.

Found what you need?

Document preview — JB/T 8734.4-2012

National Standard of the People's Republic of China

Replacing
JB/T 8734.4-1998

Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Contents

  • Foreword3
  • 1 Scope5
  • 2 Normative references5
  • 3 Operational characteristics6
  • 4 Models6
  • 5 Specifications7
  • 6 Technical requirements7
  • 6.1 General principles7
  • 6.2 Conductor8
  • 6.3 Insulation8
  • 6.4 Insulated core cabling8
  • 6.5 Sheath8
  • 6.6 Appearance dimension8
  • 7 Inspection9

1 Scope

This Part of JB/T 8734 specifies the operating characteristics, models, specifications, technical requirements and inspection of wires for internal wiring.

This Part applies to copper core polyvinyl chloride insulated wires for internal wiring of electric appliance, instrument, electronic equipment and automation equipment of AC rated voltage U0/U up to and including 300/300V.

2 Normative references

The articles contained in the following documents have become part of this document when they are quoted herein. For the dated documents so quoted, all the modifications (Including all corrections) or revisions made thereafter shall be applicable to this document.

GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 11: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties

GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 12: Methods for general application - Thermal ageing methods

GB/T 2951.13-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 13: Methods for general application - Measurement for determining the density - Water absorption tests - Shrinkage test

GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 14: Methods for general application - Test at low temperature

GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 31: Methods specific to PVC compounds - Pressure test at high temperature - Test for resistance to cracking

GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of

JB/T 8723.4-2012 electric and optical cables - Part 32: Methods specific to PVC compounds - Loss of mass test - Thermal stability test

GB/T 5023.2-2008 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Part 2: Test methods

GB/T 18380.12-2008 Test on electric and optical fibre cables under fire conditions -

Part 12: Test for vertical flame propagation for a single insulated wire or cable -

Procedure for 1kW pre-mixed flame

GB/T 18380.22-2008 Tests on electric and optical fibre cables under fire conditions -

Part 22: Test for vertical flame propagation for a single small insulated wire or cable -

Procedure for diffusion flame

JB/T 8734.1-2012 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V - Part 1: General requirements

3 Operational characteristics

3.1

Cable's rated voltage U0/U is 300/300V.

3.2

Allowable long-term working temperature of AV-90, AVR-90 type wires shall not exceed 90°C. Allowable long-term working temperature of other types wires and cables shall not exceed 70°C.

Note: When the operating environment of wires can prevent thermoplastic flow and allow reducing insulation resistance, for the polyvinyl chloride compound which can be used continuously at 90°C, its working temperature can be increased to 105°C, on the premise of shortening the total working hours.

4 Models

Wires and cables' models are shown in Table 1.

2 Structure size inspection

2.1

Structure inspection T, S T, S T, S T, S T, S T, S

Normal eyesight inspection 2.2 Conductor - conduction test R R R R R R JB/T 8734.1-2012 5.5

23 Insulation thickness T, S T, S T, S T, S T, S T, S GB/T 5023.2-2008 1.9 2.4 Sheath thickness - - - - T, S - GB/T 5023.2 2008 1.10

2.5 External diameter or appearance

dimension

T, S T, S T, S T, S T, S T, S GB/T 5023.2-2008 1.11

2.6 Ovality - - - - T, S - GB/T 5023.2-2008 1.11

3

Mechanical properties of the insulation 3.1 Tension test before aging T T T T T T GB/T 2951.11-2008 9.1 3.2 Tension test after aging T T T T T T GB/T 2951.12-2008 8.13.1

GB/T 2951.11-2008 9.1

3.3 Weightlessness test T T T T T T GB/T 2951.32-2008 8.1

4 Insulation thermal shrinkage test T T T T T T GB/T 2951.13-2008

Chapter

10

5

Mechanical properties of the sheath 5.1 Tension test before aging - - - - T - GB/T 2951.11-2008 9.2 5.2 Tension test after aging - - - - T - GB/T 2951.12-2008 8.1.3.1

GB/T 2951.11-2008 9.2

5.3 Weightlessness test - - - - T - GB/T 2951-32-2008 8.2

6 High temperature pressure test

6.1 Insulation T T T T T T GB/T 2951.31-2008 8.1

6.2 Sheath - - - - T - GB/T 2951.31-2008 8.2

7

Low temperature flexibility and shock strength

7.1 Insulation low temperature winding

test

T T T T T T GB/T 2951.14-2008 8.1

7.2 Sheath low-temperature winding

test

- - - - T - GB/T 2951.14-2008 8.2

7.3 Sheath low-temperature Tension

test

- - - - T - GB/T 2951.14-2008 8.4

7.4

Finished wires and cables - low temperature shock test

- - - - T - GB/T 2951.14-2008 8.5

8 Thermal shock test

8.1 Insulation T T T T T T GB/T 2951.31-2008 9.1

8.2 Sheath - - - - T - GB/T 2951.31-2008 9.2

9

Mechanical strength test of finished wires and cables 9.1 Insulated cores tear off test - - T - - - JB/T 8734.1-2012 5.4

10 Flame non-propagation test T T T T T T GB/T

JB/T 8723.4-2012

18380.12-2008

GB/T 18380.22-2008

11

Mark - rubbing resistance inspection

T, S T, S T, S T, S T, S T, S GB/T 5023.2-2008 1.8

12 Thermal stability test - - - - - T GB/T 2951.32-2008

Chapter

9

__________ END __________ […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

Editions of JB/T 8734.4

EditionTitleRevisionStatus
JB/T 8734.4-2012Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V - Part 4: Insulated wires for internal wiring of equipmentcurrent editionCurrent
JB/T 8734.4-1998Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V - Part 4: Insulated wires for internal wiring of equipmentprevious editionSuperseded

This page sells the current edition, JB/T 8734.4-2012. Earlier editions are listed for reference only.

How to Download JB/T 8734.4-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JB/T 8734.4-2012

$70.00