Valid

JB/T 8734.2-2012Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V - Part 2: Insulated cables and wires for fixed wiring (English PDF)

额定电压450/750V 及以下聚氯乙烯绝缘电缆电线和软线 第2部分:固定布线用电缆电线

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for JB/T 8734.2-2012 in 30 minutes.

Issued by

MIIT

Level / Type

Industry · Recommended

Issue date

May 24, 2012

Implementation date

November 1, 2012

Scope

JB/T 8734.2-2012 is the English-translated version of 额定电压450/750V 及以下聚氯乙烯绝缘电缆电线和软线 第2部分:固定布线用电缆电线.

JB/T 8734.2-2012 is the Chinese standard "Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V - Part 2: Insulated cables and wires for fixed wiring".

Its scope clause reads: This Part of JB/T 8734 specifies the operating characteristics, models, specifications, technical requirements, and inspection of cables and wires for fixed wiring.

This Part applies to copper core or aluminum core polyvinyl chloride insulated cables and wires that are used in AC rated voltage U0/U up to and including 450/750V.

Its clauses include operating characteristics; models; specifications; technical requirements; thermal shock test.

Found what you need?

Document preview — JB/T 8734.2-2012

National Standard of the People's Republic of China

Replacing
JB/T 8734.2-1998

Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Contents

  • Foreword3
  • 1 Scope5
  • 2 Normative references5
  • 3 Operating characteristics6
  • 4 Models6
  • 5 Specifications7
  • 6 Technical requirements7
  • 6.1 General principle7
  • 6.2 Conductor7
  • 6.3 Insulation7
  • 6.4 Insulated core cabling7
  • 6.5 Sheath7
  • 6.6 Appearance dimension8
  • 7 Inspection11

1 Scope

This Part of JB/T 8734 specifies the operating characteristics, models, specifications, technical requirements, and inspection of cables and wires for fixed wiring.

This Part applies to copper core or aluminum core polyvinyl chloride insulated cables and wires that are used in AC rated voltage U0/U up to and including 450/750V.

2 Normative references

The articles contained in the following documents have become part of this document when they are quoted herein. For the dated documents so quoted, all the modifications (Including all corrections) or revisions made thereafter shall be applicable to this document.

GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 11: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties

GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 12: Methods for general application - Thermal ageing methods

GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 14: Methods for general application - Test at low temperature

GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 31: Methods specific to PVC compounds - Pressure test at high temperature - Test for resistance to cracking

GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 32: Methods specific to PVC compounds - Loss of mass test - Thermal stability test

JB/T 8723.2-2012

GB/T 5023.2-2008 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Part 2: Test methods

GB/T 18380.12-2008 Test on electric and optical fibre cables under fire conditions -

Part 12: Test for vertical flame propagation for a single insulated wire or cable -

Procedure for 1kW pre-mixed flame

JB/T 8734.1-2012 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V - Part 1: General requirements

3 Operating characteristics

3.1

The rated voltages U0/U of wires and cables are 450/750V and 300/500V.

3.2

Allowable long-term working temperature of all types of cables and wires shall not exceed 70°C.

3.3

Laying temperature of cables and wires shall not below 0°C. The allowable bending radius of cables and wires, with external diameter (D) of less than 25mm, shall be not less than 4D. And allowable bending radius of cables and wires, with external diameter (D) of

25mm or above, shall not be less than 6D.

4 Models

Cables and wires' models are shown in Table 1.

Table 1 Models and names

Models Names Primary usage

BV Copper core polyvinyl chloride insulated wire Fixed wiring

BLV Aluminum core polyvinyl chloride insulated cable Fixed wiring

BVR Copper core polyvinyl chloride insulated flexible cable

Flexible site is required during fixing the wires

BVV Copper core polyvinyl chloride insulated polyvinyl chloride sheathed round cable

Fixed wiring

BLVV Aluminum core polyvinyl chloride insulated polyvinyl chloride sheathed round cable

Fixed wiring

BVVB Copper core polyvinyl chloride insulated polyvinyl chloride sheathed flat cable

Fixed wiring

BLVVB Aluminum core polyvinyl chloride insulated polyvinyl chloride sheathed flat cable

Fixed wiring

JB/T 8723.2-2012

5 Specifications

Specifications of cables and wires are shown in Table 2.

Table 2 Specifications

Models

Rated voltage V

Core number

Nominal sectional area of conductor with the unit of mm

2

Structural parameters table number

BV 300/500 1 0.75-1.0 Table 3

BLV 450/750 1 2.5-400 Table 4

BVR 450/750 1 0.75-185 Table 5

BVV 300/500 1 0.75-185 Table 6

BLVV 300/500 1 2.5-185 Table 6

BVVB 300/500 2-3 0.75-10 Table 7

BLVVB 300/500 2-3 2.5-10 Table 7

6 Technical requirements

6.1 General principle

In addition to comply with the technical requirements specified in this part, the cables and wires shall also comply with the provisions of JB/T 8734.1-2012.

6.2 Conductor

Core number and structure of conductor shall comply with the provisions in Table 3 - Table

7.

6.3 Insulation

The insulation wrapped on the conductor shall be polyvinyl chloride compound with code of PVC/C.

Insulation thickness shall comply with the provisions of Table 3 - Table 7.

Insulation resistance shall not be less than the values specified in Table 3 - Table 7.

6.4 Insulated core cabling

Insulated core of flat cable shall be placed in parallel.

6.5 Sheath

The sheath wrapped on the insulation or finished cable core shall be polyvinyl chloride compound with code of PVC/ST4.

7 Thermal shock test

7.1 Insulation T T T T T GB/T 2951.31-2008 9.1

7.2 Sheath - - - T T GB/T 2951.31-2008 9.2

8

Flame non-propagation test

T T T T T

GB/T 18380.12-2008

9

Mark - rubbing resistance inspection

T, S T, S T, S T, S T, S GB/T 5023.2-2008 1.8

__________ END __________ […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

Editions of JB/T 8734.2

EditionTitleRevisionStatus
JB/T 8734.2-2012Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V - Part 2: Insulated cables and wires for fixed wiringcurrent editionCurrent
JB/T 8734.2-1998Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V - Part 2: Insulated cables and wires for fixed wiringprevious editionSuperseded

This page sells the current edition, JB/T 8734.2-2012. Earlier editions are listed for reference only.

How to Download JB/T 8734.2-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JB/T 8734.2-2012

$90.00