JB/T 5926-1991Vibratory stress relief - Selection of process parameters and technical requirements (English PDF)
振动时效工艺参数选择及技术要求
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for JB/T 5926-1991 in 30 minutes.
Issued by
MIIT
Level / Type
Industry · Recommended
Issue date
January 1, 1991
Implementation date
January 1, 1991
Scope
JB/T 5926-1991 is the English-translated version of 振动时效工艺参数选择及技术要求.
JB/T 5926-1991 is the Chinese standard "Vibratory stress relief - Selection of process parameters and technical requirements". Its scope clause reads: This standard specifies the selection of the process parameters and the technical requirements for vibratory stress relief, and the method of assessing its effect.
It applies to the vibratory stress relief treatment of castings, forgings and welded assemblies made of carbon structural steel, low-alloy steel, stainless steel, cast iron and non-ferrous metals such as copper, aluminium, zinc and their alloys.
Found what you need?
Document preview — JB/T 5926-1991
National Standard of the People's Republic of China
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- 1 Scope
- 2 Terms
- 3 Selection of process parameters and technical requirements
1 Scope
This standard specifies the selection of the process parameters and the technical requirements for vibratory stress relief, and the method of assessing its effect.
It applies to the vibratory stress relief treatment of castings, forgings and welded assemblies made of carbon structural steel, low-alloy steel, stainless steel, cast iron and non-ferrous metals such as copper, aluminium, zinc and their alloys.
2 Terms
2.1 Frequency sweep curve
Sweeping is the process of slowly raising the frequency of the exciter from a low value to a high one. As the frequency changes, the vibration response of the workpiece changes with it. The curve showing the relationship between the vibration response and the frequency is the frequency sweep curve: A-f is the amplitude-frequency curve and a-f the acceleration-frequency curve, where A is amplitude, a is acceleration and f is frequency.
2.2 Excitation point
The point at which the exciter is clamped to the workpiece during vibratory stress relief.
3 Selection of process parameters and technical requirements
The mode shapes of the workpiece within the excitation frequency range shall first be analysed and determined.
3.2 Selection of the vibratory stress relief equipment
The excitation frequency of the equipment, hereinafter "the equipment", shall be higher than the lowest natural frequency of the workpiece. Where the maximum excitation frequency of the equipment is lower than the lowest natural frequency of the workpiece, measures such as frequency multiplication (or division) and frequency reduction shall be taken. The exciting force of the equipment shall be such that the maximum dynamic stress produced in the workpiece is one third to two thirds of the working stress. The equipment shall be able to sweep automatically, to record the sweep curve automatically and to indicate the vibration acceleration and the motor current; its speed-holding accuracy shall be within ±1 r/min.
3.3 Supporting the workpiece and mounting the exciter and the pick-up
So that the workpiece is free, it shall be supported elastically at three or four points, the supports being at or near the nodal lines of the main vibration frequency; where the workpiece is to be simply supported at both ends or cantilevered, rigid clamping shall be used.
The exciter shall be fixed rigidly at a point where the workpiece is less stiff or the amplitude is larger, but not at parts of very low strength and stiffness such as large thin-plate surfaces; the fixing surface shall be flat.
A cantilevered workpiece shall normally be turned end for end and given a second treatment. On very large workpieces, additional vibration shall be applied at the parts where the vibration response is weak.
The pick-up shall be fixed far from the exciter, at a point of larger amplitude.
3.4 Trial vibration of the workpiece
A workpiece with serious defects such as shrinkage cavities, slag inclusions, cracks or cold laps shall not be vibrated.
The eccentricity setting of the exciter shall be chosen so as to produce a large amplitude in the workpiece without overloading the equipment; where necessary the manual control shall be used first to find a suitable setting.
On the first sweep, the amplitude-frequency (A-f) curve of the workpiece shall be recorded and the resonant frequencies, the positions of the nodal lines and the positions of the peaks determined.
Where necessary, more mode shapes shall be excited by adjusting the positions of the supports, of the excitation point and of the pick-up.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download JB/T 5926-1991
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JB/T 10062-2026 — Probes used in ultrasonic flaw detection - Testing methods for performance
JB/T 10096-2026 — Cases for power semiconductor devices - Selection guidance
JB/T 10097-2026 — Case for power semiconductor device
JB/T 5926-1991
$515.00