HJ/T 37-1999Stationary source emission. Determination of acrylonitrile. Gas chromatography (English PDF)
固定污染源排气中丙烯腈的测定 气相色谱法
This is a limited preview
Buy now to download the full PDF (16 pages)
Need quotation for your management?
Get a formal quotation for HJ/T 37-1999 in 30 minutes.
Issued by
State Environmental Protection Administration
Level / Type
Industry · Recommended
Issue date
August 18, 1999
Implementation date
January 1, 2000
Scope
HJ/T 37-1999 is the English-translated version of 固定污染源排气中丙烯腈的测定 气相色谱法.
HJ/T 37-1999 is the Chinese standard "Stationary source emission. Determination of acrylonitrile. Gas chromatography". Its scope clause reads: This standard is applicable to the determination of acrylonitrile for both intentional and fugitive emissions from stationary pollution sources.
When the sampling volume is 30L, the detection limit of the method is 0.2 mg/m3. The quantitative measurement concentration range of the method is 0.26~33.0mg/m3.
Its clauses include scope of application; method principle; reagents and materials; instruments; calculation and representation of result.
Found what you need?
Document preview — HJ/T 37-1999
National Standard of the People's Republic of China
Issued by: State Environmental Protection Administration
Contents
- 1 Scope of Application3
- 2 Method Principle3
- 3 Normative References3
- 4 Reagents and Materials3
- 5 Instruments5
- 6 Sample Collection and Storage6
- 7 Analysis Procedures8
- 8 Calculation and Representation of Result9
- 9 Precision and Accuracy12
- 10 Description12
- Column Conditions13
- Additional Instructions16
1 Scope of Application
1.1
This standard is applicable to the determination of acrylonitrile for both intentional and fugitive emissions from stationary pollution sources.
1.2
When the sampling volume is 30L, the detection limit of the method is 0.2 mg/m3.
The quantitative measurement concentration range of the method is 0.26~33.0mg/m3.
2 Method Principle
Acrylonitrile (CH2=CHCH2CN) is adsorbed and enriched by activated charcoal at room temperature; and then desorbed by carbon disulfide at room temperature. The components in the desorbed liquid are separated by the chromatographic column and then enter the hydrogen flame ionization detector (FID). From the measured acrylonitrile chromatogram peak height (or area), quantify the concentration of acrylonitrile in the desorption solution; and finally calculate the concentration of acrylonitrile in the gas sample from the volume, concentration, and sampling volume of the desorption solution.
3 Normative References
The provisions in following documents become the provisions of this Standard through reference in this Standard.
GB 16297-1996 Comprehensive Emission Standard of Air Pollutants
GB 16157-1996 The Determination of Particulates and Sampling Methods of
Gaseous Pollutants Emitted from Exhaust Gas of Stationary Source
4 Reagents and Materials
4.1 Acrylonitrile
Chromatographically pure (or analytically pure, but there must be no chromatographic interference peaks for acrylonitrile).
and dilute to the mark with carbon disulfide.
5 Instruments
5.1 Gas chromatograph
Equipped with hydrogen flame ionization detector
5.2 Chromatographic column
5.2.1 Column material
Glass or PTFE.
5.2.2 Column length
3m.
5.2.3 Column inner diameter
3mm.
5.2.4 Column type
packed column.
5.2.5 In-column packing
GDX-502, 60~80mesh.
5.2.6
Preparation and aging of chromatographic column (see Appendix B).
5.3 Micro syringe
1.0µL
5.4 Sampling instrument
Refer to 9.3 in GB 16157-1996 to configure the sampling instrument.
5.4.1 Sampling instrument for intentional emission monitoring
5.4.1.1 Sampling tube
It is made of stainless steel, hard glass or PTFE, with appropriate dimensions, and is equipped with an insulation jacket that can be heated to above 120°C.
5.4.1.2 Sample collecting device
Activated charcoal adsorption tube (4.7).
5.4.1.3 Flowrate measuring device
See 9.3.6 of GB 16157-1996.
5.4.1.4 Suction pump
See 9.3.7 of GB 16157-1996.
5.4.1.5 Connecting pipe
PTFE hose or silicone rubber tube lined with PTFE film.
1-flue; 2-heating sampler; 3-bypass adsorption tube; 4-thermometer; 5-pressure gauge; 6-adsorption tube; 7-three-way valve; 8-dryer; 9-flow meter; 10- suction pump.
Figure 2 - Flue Gas Sampling System
6.1.3 Sample collection
Plug an appropriate amount of glass wool into the port of the sampling tube; then extend it to the sampling point in the exhaust cylinder; start the suction pump; and first make the gas in the exhaust cylinder circulate flow through the bypass adsorption tube to fully wash the sampling pipeline. Then let the exhaust gas pass through the adsorption tube; and record the sampling time, temperature, and flow rate. After sampling, the adsorption tube shall be removed immediately; and its two ends shall be tightly covered by plastic caps; and then take back to the laboratory for analysis.
6.1.4 Heating temperature control of sampling tube
The heating temperature of the sampling tube shall be based on the principle that water vapor and the sample do not condense on the wall of the sampling tube; but the maximum heating temperature shall not exceed 160°C. If the exhaust gas temperature is close to room temperature, the sampling tube is exempted from being heated.
6.1.5 Sampling flowrate
The sampling flowrate shall generally be controlled between 0.3L/min and 1.0L/min.
When the temperature is higher than 30°C, the sampling flow rate shall be reduced to no greater than 0.5L/min; so that ensure that the adsorption capacity of the activated charcoal in the Section-B is less than 2% of the total adsorption capacity.
6.1.6 Sampling amount
For each activated charcoal adsorption tube, the sampling amount shall be controlled to the concentration of acrylonitrile in the carbon disulfide desorption solution at
10~400µg/mL. The maximum sampling amount of each activated charcoal adsorption tube shall generally not exceed 1.6mg; and the acrylonitrile adsorbed by the activated charcoal in Section-B shall not exceed 2% of the total adsorbed amount of acrylonitrile.
6.2 Sample collection of fugitive emissions
6.2.1 Sampling location and sampling point
Determine the location of the fugitive emission monitoring point according to the provisions of Appendix C in GB 16297-1996; or determine the location of the sampling point according to other specific requirements.
6.2.2 Connection of sampling device
The solutions of each concentration are injected for three times; take the average value;
and draw the calibration curve by the concentration ci (µg/ml) and the corresponding peak height hi (or area Ai); and calculate the linear regression equation of the calibration curve.
7.3 Sample determination
7.3.1 Desorption of the sample
Open the caps at both ends of the activated charcoal adsorption tube after collecting the sample; use a hooked iron wire to take out the V-shaped spring hook pressed on the activated charcoal particles in Section-A; and respectively transfer the activated charcoal in Section-A (including the upper end of glass wool) and the activated charcoal in Section-B (including sponge) to two dry test tubes with grinding mouths;
and immediately used a pipette to pipette 2.00mL and 1.00mL of carbon disulfide; and respectively put them into the test tubes containing Section-A and Section-B activated charcoal. Quickly close the test tube stopper; and continue to gently shake the test tube; so that the carbon disulfide can be fully contacted and mixed with the activated charcoal. After 30min, perform gas chromatographic determination.
7.3.2 Gas chromatographic determination
Adjust the instrument according to the same gas chromatographic working conditions for drawing the calibration curve; and perform gas chromatographic determinations on the carbon disulfide desorbed liquids that obtain the activated carbon in Section-A and
Section-B in 7.3.1.Take the supernatant of the desorbed solution and inject the sample;
each injection volume is 1.0µL; repeat the injection for three times; and take the average value of the acrylonitrile chromatographic peak height (or area) for quantification.
8 Calculation and Representation of Result
8.1 Qualitative analysis
Be Qualitative based on the retention time of the chromatographic peak of the acrylonitrile standard sample.
For standard chromatogram, refer to Figure 3.
cb - concentration of acrylonitrile in the activated charcoal desorption solution in
Section-B, in µg/mL;
Va - volume of carbon disulfide desorption solution of activated charcoal in Section-A, in mL;
Vb - volume of carbon disulfide desorption solution of activated charcoal in Section-B, in mL;
Vnd - dry gas sampling volume converted into the standard state, in L (calculate according to 10.1 or 10.2 in GB 16157-1996).
8.3 Calculation of the "emission concentration" of acrylonitrile intentional emission
Calculate the "emission concentration" of acrylonitrile according to 11.1.2 in GB16157-
1996.
8.4 Calculation of the "emission rate (kg/h)" of acrylonitrile intentional emission
Calculate the "emission rate" of acrylonitrile according to 11.4 in GB 16157-1996.
8.5 Calculation of "fugitive emission monitoring concentration value" of acrylonitrile
8.5.1 Calculation of the average concentration of acrylonitrile at a monitoring point
Calculate the average concentration of acrylonitrile at a monitoring point for fugitive emission by the following formula.
Where.
c - average concentration of acrylonitrile at a monitoring point for fugitive emission;
ci - acrylonitrile concentration of a sample;
n - the number of samples taken at a monitoring point for fugitive emission.
8.5.2 Calculation of "fugitive emission monitoring concentration value"
According to C2.3 in Appendix C of GB 16297-1996, calculate the “fugitive emission monitoring concentration value” of acrylonitrile.
Appendix A (Standard)
Acrylonitrile-Assisted Qualitative Chromatographic Column
Conditions
A1 Stationary phase
beta, beta-Oxydipropionitrile. 6201 (60~80 mesh glazing) = 20.80
A2 Chromatographic column characteristics
A2.1 Length of column. 2m.
A2.2 Inner diameter of column. 4mm.
A2.3 Materials of column. Stainless steel.
A2.4 Detector. Hydrogen flame ionization (FID).
A3 Chromatographic conditions
A3.1 Column temperature. 80±0.5°C.
A3.2 Nitrogen flowrate. 80mL/min.
A3.3 Hydrogen flowrate. 50mL/min.
A3.4 Air flowrate. 500mL/min.
A4 Standard chromatogram
Appendix B (Standard)
Preparation and Aging of Chromatographic Column
B1 Treatment of filling
Use appropriate amount of cyclohexane (analytically pure) as extractant; elute GDX-
502 in a Soxhlet extractor for several hours; and then dry it at 30~40°C. After the cyclohexane is basically volatilized, place GDX-502 in a vacuum drying oven (or in a nitrogen atmosphere) and dry it under vacuum at 130°C for 2~3h. After the temperature drops to room temperature, take it out and pack the column.
B2 Packing of chromatographic column
One end of the glass column is plugged with glass wool; a buffer bottle and a control piston are connected; and then a vacuum pump is connected. A funnel is connected to the other end of the column. While the vacuum pump is turned on for suction, slowly add the treated dry filler GDX-502 into the funnel and put it into the glass column. Use a piston to control the pumping speed; pump and fill at the same time. And gently vibrate the glass column at the same time (a small electric massager can be used to continuously massage and vibrate the glass column for about 20min) until the filling is tightly and evenly packed in the column. After filling, plug the other end of the column with glass wool.
B3 Aging of chromatographic column
Place the packed chromatographic column to the injection port of the chromatograph, without a detector at the outlet; pass N2 gas at a flow rate of 30mL/min; gradually increase the column temperature to 150°C; and age for 7~10h until the baseline is stable.
HJ 38-2017 | HJ/T 40-1999 | HJ 75-2017 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
Referenced standards
How to Download HJ/T 37-1999
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 16297-1996 — Integrated emission standard of air pollutants
HJ/T 298-2007 — Technical specifications on identification for hazardous waste
HJ/T 299-2007 — Solid waste. Extraction procedure for leaching toxicity. Sulphuric acid and nitric acid method
Secure payment via Stripe
Payments accepted
HJ/T 37-1999
$145.00