Valid

HJ 917-2017Stationary source emission--Determination of total gaseous mercury --Carbon sorbent traps / thermal cracking atomic absorption spectrophotometric method (English PDF)

固定污染源废气 气态汞的测定 活性炭吸附热裂解原子吸收分光光度法

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for HJ 917-2017 in 30 minutes.

Issued by

Ministry of Ecology and Environment

Level / Type

National · Mandatory

Issue date

December 28, 2017

Implementation date

April 1, 2018

Scope

HJ 917-2017 is the English-translated version of 固定污染源废气 气态汞的测定 活性炭吸附热裂解原子吸收分光光度法.

HJ 917-2017 — This standard specifies the determination of gaseous fixed-source emissions of mercury in activated carbon adsorption/thermal cracking atomic absorption spectrophotometry.

This standard applies to the installation of denitration, dust removal, desulfurization of coal-fired power plant emissions of mercury in the determination of gaseous mercury.

When the sampling volume is 10 L (dry flue gas under standard conditions), the detection limit is 0.1 µg/m3 and the lower limit of determination is 0.4 µg/m3.

Found what you need?

Document preview — HJ 917-2017

National Standard of the People's Republic of China

Classification
Z 25

Issued by: Ministry of Ecology and Environment

Contents

  • Foreword .ii
  • 1 Scope of application .1
  • 2 Normative references .1
  • 3 Method principle .1
  • 4 Interference and elimination .1
  • 5 Reagents and materials .1
  • 6 Instruments and equipment .2
  • 7 Samples .3
  • 8 Analysis steps .4
  • 9 Results Calculation and Presentation .4
  • 10 Precision and accuracy
  • 11 Quality Assurance and Quality Control .5
  • 12 Waste treatment
  • 13 Matters needing attention

Foreword

In order to implement the Law of the People's Republic of China on Environmental Protection and the Law of the People's Republic of China on Prevention and Control of Atmospheric Pollution, Habitat, to protect human health, standardize the determination of gaseous mercury in the exhaust gas pollution sources, the development of this standard.

This standard specifies the determination of gaseous fixed-source emissions of mercury in activated carbon adsorption/thermal cracking atomic absorption spectrophotometry.

This standard is released for the first time.

This standard by the Environmental Protection Department of Environmental Monitoring Division and Science and Technology Standards Division to develop.

This standard was drafted. National Environmental Analysis Test Center.

This standard verification unit. Beijing Environmental Protection Monitoring Center, Xinjiang Uygur Autonomous Region Environmental Monitoring Station, China Central Environmental Science Research Institute, Tsinghua University, Chaoyang District, Beijing Environmental Protection Monitoring Station and Binhai New Area, Tianjin Environmental Protection Monitoring Station.

This standard MEP approved on December 28, this standard since April 1, 2018 come into operation.

This standard is interpreted by the MEP.

Stationary source emissions - Determination of gaseous mercury - Activated carbon adsorption/thermal cracking Atomic absorption spectrophotometry Warning. The sulfuric acid used in the experiment has a strong corrosive, HgCl2 standard solution is toxic, reagent preparation process should be carried out in the fume hood, operation should be required to wear protective equipment, to avoid inhalation of the respiratory tract and skin, clothing.

1 Scope of application

This standard specifies the determination of gaseous fixed-source emissions of mercury in activated carbon adsorption/thermal cracking atomic absorption spectrophotometry.

This standard applies to the installation of denitration, dust removal, desulfurization of coal-fired power plant emissions of mercury in the determination of gaseous mercury.

When the sampling volume is 10 L (dry flue gas under standard conditions), the detection limit is 0.1 µg/m3 and the lower limit of determination is 0.4 µg/m3.

2 Normative references

This standard references the following documents or the terms. For undated references, the effective version applies to this book standard.

Determination of Particulate Matter and Gaseous Pollutants in Exhaust of Fixed Pollution Sources GB/T 16157

3 Method principle

Through this standard sampling system, the exhaust gas in the effective enrichment of gaseous mercury in the iodine or other halogen and its compounds Treated activated carbon material, using direct pyrolysis atomic absorption spectrophotometry Determination of activated carbon in the adsorbent tube of mercury in the material Content, based on the sampling volume, calculate the concentration of gaseous mercury.

4 Interference and elimination

SO2, NOX will inhibit the capture of mercury on the activated carbon, dioxide compounds in the front of the adsorption tube to remove acid gas interference.

5 Reagents and materials

Unless otherwise specified, all analytical reagents used in the analysis are in accordance with national standards. The experimental water is freshly prepared deionized water or distilled water.

5.1 Mercury chloride (HgCl2).

5.2 Sulfuric acid. rho (H2SO4) = 1.84 g/ml.

5.3 sulfuric acid solution. c (1/2 H2SO4) = 0.5 mol/L.

Pipette 6.9 ml sulfuric acid (5.2) slowly adding an appropriate amount of water, diluted after cooling, constant volume to 500 ml, mix.

5.4 Mercury standard stock solution. rho (Hg) = 1000 mg/L.

Weigh 0.1354 g mercuric chloride (5.1), with sulfuric acid solution (5.3) dissolved and diluted to a constant volume of 100 ml. Can also be used Mercury certified reference material on the market.

5.5 Mercury standard solution. rho (Hg) = 10.0 mg/L.

Remove the standard stock solution of mercury (5.4) 1.00 ml, dilute it with sulfuric acid solution (5.3) to make a volume of 100 ml. Pro use now with.

6 Instruments and equipment

6.1 Sampling System

6.1.1 Sampling system components

Typical gaseous mercury sampling systems typically include activated carbon sorbent tubes, sampling probes, temperature sensors, dehumidification units, Sampling controller, sampling pump, see Figure 1.

Figure 1 Typical gaseous mercury sampling system

6.1.2 Activated carbon adsorption tube
6.1.2.1 Two-stage

The adsorption tube contains two sections of specially prepared activated carbon treated with iodine or other halogen and its compounds and each section can be divided Analysis, see Figure 2.

Figure 2 two-stage activated carbon adsorption tube

6.1.2.2 Three-stage type

Adsorption tube equipped with three sections of special activated carbon, which plus the standard section of activated carbon to add a known quality of mercury, can also be used on the market Activated carbon tubes have been spiked, see Figure 3.

Figure 3 Three-stage activated carbon adsorption tube

6.1.3 Sampling probe

Probe with heating function (heating temperature not less than 120 °C), to prevent flue gas condensation.

6.1.4 Temperature sensor

Measurement accuracy within ± 1.5 °C.

6.1.5 Dehumidification device

Before the airflow enters the sampling controller, the dehumidifier should be used to remove the water vapor from the airflow.

6.1.6 Sampling controller

Used to determine the total volume of dry flue gas, you can control the sampling flow to maintain within ± 10%.

6.1.7 Sampling pump

Power should be able to meet the system flow range requirements.

6.2 Mercury analyzer

Has a thermal cracking unit, the sample of mercury atomized to form gaseous mercury, atomic absorption spectrophotometric quantitative analysis Mercury, the detection limit should be less than 2.0 µg/kg.

6.3 Other

Common laboratory equipment and equipment.

7 Samples

7.1 Sample Collection

Fixed pollution source sampling and laying of sampling points should be consistent with GB/T 16157 in the relevant provisions. Before and after sampling should be Airtight testing. For each sampling, two activated carbon adsorption tubes (6.1.2.1) must be used for parallel and dual sampling, with a flow rate of 0.2 L/min ~ 0.6 L/min, the sampling time should not be less than 30 min. After sampling, record the sampling time, the atmosphere Pressure Remove the sampled activated carbon tube and seal both ends to wipe off the deposits on the outer wall of the tube.

At least one blank activated carbon adsorption tube (6.1.2.1) shall be taken for each sampling, taken to the sampling site as a complete program empty White samples are stored with the collected samples and brought back to the laboratory for analysis.

7.2 Sample Storage

All samples should be stored in sealed sample storage container at room temperature, the sample can be stored for 14 d.

7.3 Dynamic spiked samples

Take a three-stage adsorption tube (6.1.2.2) and perform dynamic spiking of the sample according to the same procedure (7.1) as for sample collection of the collection, the standard addition should be 50% of the actual amount of mercury samples to 150%, each batch should be collected a dynamic spiked samples.

7.4 Laboratory blank samples

Blank activated carbon adsorption tubes (6.1.2.1) were used as laboratory blank samples.

8 Analysis steps

8.1 Instrument analysis reference conditions

Optimize assay conditions or parameters based on instrument user's manual. Thermal cracking temperature should be greater than 650 °C.

8.2 Standard curve established

Pipette Mercury standard solution (5.5) 0 µl, 10.0 µl, 20.0 µl, 40.0 µl, 60.0 µl, 80.0 µl and 100 µl to the sample boat, the mercury contents were 0 ng, 100 ng,.200 ng, 400 ng, 600 ng, 800 ng and 1000 ng Standard series. According to mercury analyzer operating procedures were measured, the instrument response to mercury content to establish a standard curve.

Note. The standard curve can also be weighed with different quality soil or sediment containing mercury standard preparation.

8.3 Sample Determination

The activated carbon adsorption tube at both ends of the seal cap is opened, the interval of quartz wool and each section of activated carbon were transferred to the sample boat , The sample was measured under the same conditions as in the standard curve (8.2).

8.4 Determination of blank samples

8.4.1 Determination of the entire program blank samples

According to the same conditions with the sample (8.3) were measured to determine the entire program blank sample mercury content.

8.4.2 Laboratory blank sample determination

The mercury content of the laboratory blank samples (7.4) was determined according to the same conditions as the samples (8.3).

9 Results calculated and expressed

9.1 Calculation Results

The concentration of gaseous mercury in the exhaust gas of fixed sources is calculated according to formula (1) nd V mmm 1 2 0 -= (1) where. - Gaseous mercury concentration in dry flue gas at standard conditions (273.15 K, 101.325 kPa), µg/m3;

m1 - the mercury content measured in the first paragraph of the adsorption tube, ng;

m2 - measured in the second paragraph of the adsorption tube mercury content, ng;

m0 - laboratory mercury content in blank samples, ng;

Vnd - the standard state of the sample volume of dry gas, L.

9.2 Results indicated

When the test result is less than 100 µg/m3, keep one decimal place; when the test result is greater than or equal to 100 µg/m3, Keep 3 significant digits.

10 Precision and accuracy

10.1 Precision

In six laboratories, gaseous mercury simulated flue gas was repeatedly collected at concentrations of 5.0 µg/m3, 20.0 µg/m3 and 40.0 µg/m3 Six samples were collected for determination. The relative standard deviations in the laboratory were 4.8% -9.7%, 7.5% -9.9% and 7.1% -9.6% respectively.

The relative standard deviations (RSDs) were 4.5%, 4.1% and 4.7%, respectively. The repeatability limits were 1.1 µg/m3 and 5.4 µg/m3, 8.9 µg/m3; reproducibility limits were 1.2 µg/m3, 5.5 µg/m3 and 9.5 µg/m3, respectively.

10.2 Accuracy

In six laboratories, gaseous mercury simulated flue gas was repeatedly collected at concentrations of 2.0 µg/m3, 20.0 µg/m3 and 50.0 µg/m3 Six samples were collected for determination. the relative errors were -9.3% -7.9%, 0.0% -10.0%, -10.0% -2.3%, respectively;

The final error values were -1.8% ± 6.0%, 6.4% ± 4.3%, - 8.5% ± 3.0%.

11 Quality Assurance and Quality Control

11.1 Blank sample

The sampling volume of 10L, the whole program blank sample (8.4.1) should not exceed the detection limit; sample body Product is 10 L, the laboratory blank sample measured value (8.4.2) should not exceed the detection limit.

11.2 Standard curve

The correlation coefficient of the standard curve should be >=0.999.

11.3 Parallel samples

When the mercury concentration > 1 µg/m3, the relative deviation (RD) of the parallel sample determination is less than or equal to 10%; when the mercury concentration is less than or equal to 1 µg/m3, the relative deviation (RD) of parallel samples was <=20%.

11.4 Penetration rate

When the mercury concentration > 1 µg/m3, the absorption tube penetration B <= 10%; when the mercury concentration <= 1 µg/m3, the penetration rate B<=20%. According to the formula (2) Calculate the absorption tube penetration rate.

Where. B-pipe penetration rate,%;

m2 - the second section of the adsorption tube activated carbon measured mercury content, ng;

m1-adsorbed tube in the first paragraph of the activated carbon measured mercury content, ng.

11.5 Dynamic spike recovery

The dynamic spiked sample recovery R is between 85% and 115%.

12 Waste treatment

Hg waste gas generated in the experiment before the exclusion of the use of halogen-containing activated carbon adsorption, waste generated by the waste should be concentrated Set, and make the appropriate logo, commissioned by a qualified unit for processing.

13 Precautions

13.1 Adsorption tube must be installed in the probe so that the flue gas directly into the adsorption tube, to ensure that there is no vent between the probe and the adsorption tube leak.

13.2 Sampling, the flow rate to be controlled within the specified range, the flow is too high can easily lead to the penetration of activated carbon.

13.3 Sampling process, particulate matter may lead to blockage of the sampling tube and affect the normal sampling work, with a smaller flow, more Long time sampling, access to a sufficient amount of the test pollutants.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

How to Download HJ 917-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

HJ 917-2017

$225.00