HJ 849-2017Water quality - Determination of ethylenethiourea - High performance liquid chromatography (English PDF)
水质 乙撑硫脲的测定 液相色谱法
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for HJ 849-2017 in 30 minutes.
Issued by
Ministry of Ecology and Environment
Level / Type
National · Mandatory
Issue date
August 28, 2017
Implementation date
November 1, 2017
Scope
HJ 849-2017 is the English-translated version of 水质 乙撑硫脲的测定 液相色谱法.
HJ 849-2017 — This standard specifies the liquid chromatography for the determination of ethylene thiourea in water. This standard is applicable to the determination of ethylene thiourea in surface water, groundwater, domestic sewage and industrial waste water.
When the injection volume was 20 µl, the detection limit was 3 µg/L and the lower limit was 12 µg/L.
Found what you need?
Document preview — HJ 849-2017
National Standard of the People's Republic of China
- Classification
- Z 16
Issued by: Ministry of Ecology and Environment
Contents
- Foreword
- 1 Scope of application
- 2 Normative reference documents
- 3 Principle of the method
- 4 Interference and elimination
- 5 Reagents and materials
- 6 Instruments and equipment
- 7 Samples
- 7.1 Sample collection and storage
- 7.2 Sample preparation
- 7.3 Blank sample preparation
- 8 Analysis steps
- 8.1 Chromatographic reference conditions
- 8.2 Calibration curve establishment
- 8.3 Determination
- 38.4 Blank test
Foreword
In order to implement the Environmental Protection Law of the People's Republic of China and the Law of the People's Republic of China on the Prevention and Control of Water Pollution, Barrier to human health, regulate the determination of water thiodide in water method, the development of this standard.
This standard specifies the liquid chromatography for the determination of ethylene thiourea in water.
This standard is the first release.
This standard is organized by the Environmental Monitoring Department of the Ministry of Environmental Protection and the Department of Science and Technology Standards.
The main drafting unit of this standard. Qingdao Environmental Monitoring Center Station and China Ocean University.
The main verification unit of this standard. Ministry of Agriculture, Agricultural Product Quality Supervision, Inspection and Testing Center (Qingdao), Shandong Province Environmental Monitoring Central Station, Jinan City Environmental Monitoring Center Station, Tai'an City Environmental Protection Monitoring Station, Liaoning North Environmental Testing Technology Co., Ltd. and Green Island One Monitoring Co., Ltd.
The environmental protection department of this standard approved on August 28, 2017.
This standard has been implemented since November 1, 2017.
This standard is explained by the Ministry of Environmental Protection.
Determination of water quality of ethyl thiourea by liquid chromatography Warning. Ethylene thiourea is a carcinogen, the standard solution should be prepared in the operation of the fume hood, the operation should be required Wear protective equipment to avoid contact with skin and clothing.
1 Scope of application
This standard specifies the liquid chromatography for the determination of ethylene thiourea in water.
This standard is applicable to the determination of ethylene thiourea in surface water, groundwater, domestic sewage and industrial waste water.
When the injection volume was 20 µl, the detection limit was 3 µg/L and the lower limit was 12 µg/L.
2 Normative reference documents
The contents of this standard refer to the following documents or their terms. Those who do not specify the date of the reference file, the effective version of the appropriate for this standard.
Technical specification for surface water and wastewater monitoring Technical specification for groundwater environmental monitoring
3 Principle of the method
The aqueous thiourea in water was injected directly by liquid chromatography with an ultraviolet detector. According to the retention time Qualitative and external standard method.
4 Interference and elimination
When the organic matter in the water sample interferes with the determination of ethylene thiourea, by changing the chromatographic conditions, so that the thiodide thiourea and dry Disassociation, or the water sample first with n-hexane extraction to remove part of the interference, take the water phase for analysis.
5 Reagents and materials
The experimental water is pure water containing no organic matter.
5.1 methanol (CH3OH). liquid chromatography pure.
5.2 Ethylene thiourea. purity >= 98.5%.
5.3 Ethylene thiourea standard stock solution. rho = 100 µg/ml.
Weigh 0.010 g (accurate to 0.1 mg) ethylene thiourea (5.2), dissolved in water to 100 ml, frozen at 4 ° C, Dark and sealed can be kept for 3 months, or direct purchase of certified standard solution.
5.4 Ethylene thiourea standard use of liquid. rho = 10.0 µg/ml.
Accurately remove 1.00 ml of ethyl thiourea standard stock solution (5.3) and dilute to 10 ml with water.
6 Instruments and equipment
6.1 Sampling vials. 100 ml brown glass jar with a mouth plug.
6.2 Liquid Chromatograph. with UV detector or diode array detector.
26.3 Column. Reagent column with 5 µm ODS, 25 cm in length and 4.6 mm in diameter, or other equivalent column.
6.4 Micro Samplers. 10 µl, 50 µl and 100 µl.
6.5 Filtration. 0.22 µm nylon filter or acetate filter.
6.6 Common laboratory equipment and equipment.
7 Samples
7.1 Sample collection and storage
Samples were collected according to the relevant regulations of HJ/T 91 and HJ/T 164. The collected water samples should be refrigerated at 4 ° C, protected from light and sealed Save, within 30 d analysis is completed.
7.2 Sample preparation
The water sample was filtered through a 0.22 µm filter (6.5) and placed in a vial and tested.
Note. For samples containing organic matter, take 10 ml of water samples, with 2 ml of n-hexane extraction, take the water phase for determination.
7.3 Blank sample preparation
The sample was prepared in the same manner as in Sample Preparation Step (7.2).
8 Analysis steps
8.1 Chromatographic reference conditions
Mobile phase A. methanol; mobile phase B. water; flow rate. 0.8 ml/min; column temperature. 30 °C; detection wavelength. 233 nm;
Injection volume. 20 µl. The elution procedure is shown in Table 1.
Table 1 elution program
Time (min) A (%) B (%) Note. After 6 minutes elution, the cleaning column can be used to clean the column. The cleaning time can be adjusted according to the complexity of the actual sample.
8.2 Calibration curve establishment
Respectively, take appropriate amount of thiodide standard use of liquid (5.4), diluted with water, the preparation of at least five concentrations of the standard series, the concentration of ethylene thiourea was 10.0, 50.0, 250, 500, 1000 µg/L (reference concentration). From low concentration to High concentration followed by the standard series of solution injection to the concentration of ethylene thiourea as the abscissa, the corresponding peak area or peak height Calculate the calibration curve.
8.3 Determination
The sample to be tested (7.2) was subjected to the same conditions as the calibration curve.
38.4 Blank test
The blank sample to be measured (7.3) was measured under the same conditions as the sample.
9 Results calculation and representation
9.1 Qualitative analysis According to the samples in the ethylene thiourea and standard series of ethylene thiourea retention time for qualitative, if necessary, the standard sample Product addition method, absorption ratio at different wavelengths or scanning ultraviolet absorption spectroscopy and other methods to assist qualitative.
Figure 1 shows the chromatograms of the thiourea under the chromatographic conditions recommended in this standard (8.1).
Figure 1 Standard phase chromatogram of ethylene thiourea
9.2 Quantitative analysis the concentration of ethylene thiourea in water samples is calculated according to the following formula.
Where. - mass concentration of ethylene thiourea in water sample, µg/L;
A - the peak area or peak height of ethylene thiourea;
a - the intercept of the calibration curve;
b - the slope of the calibration curve;
f - the dilution factor of the water sample.
9.3 The result is shown when the determination result is greater than or equal to 100 µg/L, the data retained three significant digits; when the determination result is less than 100 µg/L, Reserved to integer bits.
10 precision and accuracy 10.1 precision Six laboratories were tested for white water thiazide with a concentration of 10.0 µg/L, 100 µg/L and 800 µg/L.
The relative standard deviations in the laboratory were 3.0% ~ 9.0%, 0.8% ~ 3.1%, 0.3% ~ 1.1% respectively.
The relative standard deviations were. 8.0%, 5.8%, 3.1%, and the repeatability r was 2 µg/L, 6 µg/L and 17 µg/L, respectively.
The current limit R is. 3 µg/L, 18 µg/L, 72 µg/L.
Six laboratories were tested for surface water spiked with thiodide concentrations of 5.0 µg/L, 10.0 µg/L and 50.0 µg/L for 6 the relative standard deviations in the laboratory were 2.0% ~ 7.5%, 2.7% ~ 9.0%, 0.6% ~ 4.8% respectively.
The relative standard deviations were 8.4%, 10% and 4.6%, respectively. The repeatability r was 1 µg/L, 2 µg/L and 4 µg/L respectively.
The limit R is. 1 µg/L, 3 µg/L, 8 µg/L.
6 laboratories were tested for samples of domesticated sulfur thiourea concentrations of 10.0 µg/L, 50.0 µg/L and 300 µg/L 6 times repeated determination. the relative standard deviation in the laboratory were. 4.0% ~ 9.4%, 0.4% ~ 3.8%, 0.4% ~ 4.1%; real the relative standard deviations were 12%, 9.5% and 12%, respectively. The repeatability r was 2 µg/L, 3 µg/L and 19 µg/L, respectively.
Reproducibility R was. 4 µg/L, 13 µg/L, 107 µg/L.
The concentration of thiourea in the two laboratories was 42 µg/L to 77 µg/L, 241 µg/L to 355 µg/L, 371 µg/L to 589 µg/L industrial wastewater samples were subjected to six repeated measurements. the relative standard deviations in the laboratory were. 2.6% ~ 11%, 0.4% ~ 4.6%, 0.9% ~ 3.8%. The relative standard deviations were 25%, 13% and 15%, the repeatability r was 9 µg/L, 19 µg/L, 20 µg/L, and the reproducibility limit was 41 µg/L, 109 µg/L and 202 µg/L.
10.2 Accuracy
Six labs were divided into two groups. white thiourea concentration of 10.0 µg/L, 100 µg/L and 800 µg/L the recoveries were 100% ~ 120%, 97.0% ~ 113%, 99.0% ~ 108%, respectively. The recoveries were the final Value. 105% ± 16.8%, 103% ± 12.0%, 102% ± 6.4%.
Six laboratories were divided into two groups with samples of surface thalidene thiourea concentrations of 5.0 µg/L, 10.0 µg/L and 50.0 µg/L the recoveries were 80.6% ~ 108%, 85.2% ~ 115% and 93.1% ~ 107%, respectively. The recoveries were the final Values. 98.0% ± 18.4%, 102% ± 19.3%, 100% ± 9.6%.
6 laboratories were tested for samples of domesticated sulfur thiourea concentrations of 10.0 µg/L, 50.0 µg/L and 300 µg/L the recoveries were 80.9% ~ 112%, 87.7% ~ 115%, 95.6% ~ 129%, respectively. The recoveries were the most the final values were 96.6% ± 23.4%, 96.7% ± 18.8% and 104% ± 25.0% respectively.
Six laboratories were tested for industrial waste water with a sample of 25.0 µg/L, 300 µg/L and 500 µg/L the recoveries were 83.3% ~ 104%, 75.2% ~ 109%, 71.1% ~ 112%, respectively. The final recoveries were as follows.
93.8% ± 16.4%, 91.9% ± 21.4%, 91.0% ± 27.0%.
11 quality assurance and quality control 11.1 blank test Every 20 samples or per batch (less than 20 samples) should be at least one lab blank, blank in the thiourea Concentration should be lower than the method detection limit.
11.2 Initial calibration the correlation coefficient of the calibration curve is >=0.995.
11.3 Standard curve verification for every 20 samples or per batch (less than 20 samples), a calibration curve should be measured for the intermediate concentration of the standard solution.
The relative deviation between the result and the concentration of the curve should be <=15%. Otherwise, a new calibration curve should be established.
11.4 parallel samples 5 per 10 samples or per batch (less than 10 samples) should be accompanied by a parallel sample, parallel to the relative deviation of <= 15%.
11.5 matrix spikes
Every 20 samples or each batch (less than 20 samples) need to do a matrix plus standard, the matrix spike recovery rate should be controlled in 70% to 130%.
12 Waste treatment
The organic waste generated in the experiment should be collected and kept collectively and entrusted with qualified units for processing.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
How to Download HJ 849-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
HJ 1409-2025 — Technical guidelines for environmental impact assessment - Marine ecology and environment
HJ 1410.1-2025 — Basic dataset of derivation of water quality criteria for aquatic organisms - Part 1: General principles
HJ 1410.10-2025 — Basic dataset of derivation of water quality criteria for aquatic organisms - Part 10: Mollusca
Secure payment via Stripe
Payments accepted
HJ 849-2017
$165.00