Scope

HJ 813-2016 is the English-translated version of 水中钋-210的分析方法.

HJ 813-2016 — This standard specifies the determination of polonium-210 in water. This standard applies to surface water, seawater, groundwater and nuclear industry wastewater discharge.

The measurement range of this method is. the activity concentration is greater than 1 × 10-3Bq/L.

Found what you need?

Document preview — HJ 813-2016

National Standard of the People's Republic of China

Classification
Z 33
Replacing
GB/T 12376-1990

Issued by: Ministry of Ecology and Environment

Contents

  • Preface
  • 1 Scope of application
  • 2 Normative reference document
  • Principle of Method
  • 4 Reagents and materials
  • 5 Instruments and equipment
  • 6 The scale of the instrument
  • 7 Sample collection
  • 8 Analysis Procedure
  • 9 Blank experiment
  • 10 Results calculated
  • Quality control
  • 12 Uncertainty Assessment .4
  • Appendix A

Foreword

In order to implement the Environmental Protection Law of the People's Republic of China and the Law of the People's Republic of China on the Prevention and Control of Radioactive Pollution, Protect the human health, regulate the environmental monitoring methods, the development of this standard.

This standard specifies the method of analysis of polonium-210 in water.

This standard is the "water polonium -210 analysis method electroplating sample preparation method" (GB 12376-90) revision, the use of the analysis side Principle and the original standard is basically the same, the main technical content has updated changes.

"Determination of polonium-210 in the electroplating method" (GB 12376-90) was first released in 1990, the original standard draft Unit for the Nuclear Industry Corporation Beijing Institute of uranium mining and smelting. The main technical contents of this standard are as follows.

- delete the "plating sample preparation method" and other non-standard text expression;

- revised methodological principles;

- introduced polonium -209 tracer;

- Partial revision of the analytical procedures;

- self-deposition material replaced by silver by the original standard copper;

- the measuring instrument is replaced by the alpha energy spectrometer with the original standard low background alpha, beta proportional counter;

- revised the results of the calculation formula;

- Increased assessment of the uncertainty of the results;

- Blank experiment and quality control made clear requirements;

Since the implementation of this standard, the former State Environmental Protection Bureau on June 9, 1990 approved and issued the People's Republic of China national standard Quasi "water polonium -210 analysis method electroplating method" (GB 12376-90) abolished.

The appendix to this standard is an informative appendix.

This standard is organized by the Ministry of Environmental Protection Nuclear Safety Management Division, Science and Technology Standards Division.

The main drafting of this standard. Ministry of Environmental Protection Radiation Environmental Monitoring Technology Center (Zhejiang Province, radiation environmental monitoring station).

The environmental protection department of this standard approved on October 12, 2016.

This standard has been implemented since November 1, 2016.

This standard is explained by the Ministry of Environmental Protection.

Analysis of polonium - 210 in water

1 Scope of application

This standard specifies the determination of polonium-210 in water.

This standard applies to surface water, seawater, groundwater and nuclear industry wastewater discharge.

The measurement range of this method is. the activity concentration is greater than 1 × 10-3Bq/L.

2 Normative reference documents

The contents of this standard refer to the following documents or their terms. Those who do not specify the date of the reference file, the effective version of the appropriate for this standard.

GB 12997 water quality sampling program design technical specifications Technical Guidance for Water Quality Sampling Technical specification for preservation and management of samples for water quality sampling Technical specification for radiation environmental monitoring of HJ/T 61

3 Principle of the method

Water samples were added to the known 209Po tracer, with iron hydroxide as carrier, adsorbed in water carrying 210Po and 209Po. Hydrochloric acid dissolved After precipitation, add ascorbic acid and hydroxylamine hydrochloride to restore ferric iron. In the hydrochloric acid system, 210Po and 209Po were self-deposited to pure silver on. Measured in the alpha spectrometer, according to 210Po and 209Po count, calculate the concentration of 210Po activity in water.

When each sample contains 25 µg of gold, 25 µg of platinum, 25 µg of tellurium, 50 µg of mercury and 100 µg of vanadium, the 210Po results are low.

4 Reagents and materials

Unless otherwise stated, analytical pure chemical reagents conforming to national standards are used in the analysis, and the test water is freshly prepared.

Ionized water or distilled water.

4.1 ascorbic acid (C6H8O6).

4.2 potassium permanganate solution (KMnO4) solution. 2% (m/V).

4.3 concentrated hydrochloric acid (HCl). mass concentration of 36.0% ~ 38.0% (m/m). The

4.4 Hydrochloric acid. 1 mol/L.

4.5 hydrochloric acid. 0.5mol/L.

4.6 Hydrochloric acid. 0.1 mol/L.

4.7 ferric chloride (FeCl3) solution. 20mgFe/mL, 0.1mol/L hydrochloric acid system.

4.8 ammonia (NH3 · H2O). mass concentration of 25% to 28% (m/m).

4.9 Hydrogen Peroxide (H2O2). Concentration Concentration 30% (m/m).

4.10 Hydroxylamine hydrochloride (NH2HClOH). mass concentration 25% (m/m)

4.11 anhydrous ethanol (C2H5OH). content of not less than 99.5% (m/m).

4.12 polonium -209 standard solution. 0.1 Bq/mL, 1 mol/L hydrochloric acid system.

4.13 pH test paper. pH = 0.5 ~ 5.5 and pH = 5.5 ~ 9.0.

4.14 silver. thickness 0.5mm, diameter 21mm. Before use, the silver side should be coated with paint, the other side with water sandpaper throwing Light, clean water after drying dry.

5 Instruments and equipment

5.1 alpha spectrometer, the background is less than 1 cph.

5.2 Analysis of balance, the amount of 0.1 mg.

5.3 Magnetic heating electric stirrer.

5.4 hot plate.

5.5 Oven.

6 the scale of the instrument

6.1 Energy scale The energy scale is used to store the energy of the energy spectrum with mixed plating. The result is preserved.

6.2 Efficiency scale Use the mixed plating alpha surface source to perform the efficiency scale on the energy spectrum, and take the average value as the instrument efficiency value.

7 Sample collection

7.1 Acquisition and storage

Samples were collected and stored in accordance with the relevant provisions in GB 12997, GB 12998 and HJ 493.

7.2 Pretreatment of the sample

After the sample collection, add concentrated hydrochloric acid acidification, pH 8 analysis procedures

8.1 Accurately measure 5L of filtered water, add 1 mL of 209Po standard solution (4.12), add 2 to 3 drops Potassium permanganate solution (4.2) until the water samples were stable lavender, allowed to stand for 30 min.

8.2 Add 5.0 mL of ferric chloride solution (4.7) and stir until the solution is homogeneous and heated to 600 ° C on the hot plate.

under.

8.3 Slowly add ammonia (4.8) with stirring until pH = 9.2 (measured with a precision pH test strip), stir every half hour Once, until no floating suspension, standing overnight.

8.4 Dilute (or siphon) the supernatant and filter. Wash the beaker and filter paper 3 times with deionized water and discard the filtrate.

8.5 with 6 ~ 8 mL hydrochloric acid (4.4) dissolved precipitate, the filtrate collected in 100 mL beaker. Followed by 10 mL of hydrochloric acid (4.6) and 5 mL of deionized water to clean the filter paper and the cleaning solution is combined into the beaker.

8.6 Add 2 to 3 drops of hydrogen peroxide (4.9) to the beaker and slightly soak for 3 min on the hot plate.

8.7 After the solution is slightly cold, add 2 ~ 3 g ascorbic acid (4.1) and 0.5 mL hydroxylamine hydrochloride (4.10), add 30 ~ 40 mL Hydrochloric acid (4.6), control acidity of 0.2 ~ 0.5 mol/L, the total volume of about 70 mL.

8.8 Place the stirrer into the beaker, bracket, surface dish and silver (4.14). The whole beaker is placed in the crystal dish and filled Water, open heating and stirring function, self-deposition 1 ~ 2 h.

8.9 Remove the silver, first with deionized, and then immersed in anhydrous ethanol (4.11) soak for about 20 min. Remove, deionize After the water rinse naturally dry, coated with paint on the sample label, and then placed in the 1100C constant temperature drying oven for 1 h.

8.10 silver chip into the alpha spectrometer continuous counting 48 h.

9 Blank experiment

Regular blank experiment, whenever the replacement of reagents, should be blank experiments; each batch of samples should be blank Experiment; under normal circumstances the number of blank samples should not be less than 5% of the total number of sample analysis. The method is as follows.

9.1 Take four 5 L of deionized water, with hydrochloric acid to adjust the pH Appendix A

(Informative)

Supplement to the implementation of the standard A.1 If the solution becomes black during self deposition, deionized water may be added and the self-deposition time may be reduced.

A.2 Self-deposition If you find a lot of foam above the solution, you can use glass rods or filter paper to clean up.

A.3 ferric hydroxide precipitation filter should be dissolved as soon as possible after overnight, the difficulty of dissolution increased.

A.4 If the 210Po content in the water sample is greater than 0.2Bq/L, 50mL sample can be taken directly, the acidity is 0.2 ~ 0.5M with hydrochloric acid, After adding the tracer, follow the procedure of 8.7 ~ 8.10.

A.5 If the 210Po peak area of the alpha spectrometer is large, there is overlap interference to 209Po, the sample can be diluted or reduced, and then Re-analysis once, can effectively reduce the 210Po peak to 209Po peak interference.

A.6 If silver appears black, indicating that self-deposition is not ideal, should be re-analysis.

A.7 If the silver plate caused by the surface is not flat, will increase the alpha-ion scattering, affecting the tail.

A.8 Calculate the time of sample counting according to the following formula.

22EN

NNN

T bccc

Where.

Tc - the time of sample counting, s;

Nc - the total count rate of the sample source plus the background, s-1;

Nb - background count rate, s-1;

N - sample net count rate, s-1;

E - the predetermined relative standard error.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.

How to Download HJ 813-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
8 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

HJ 813-2016

$180.00