Scope

HJ 754-2015 is the English-translated version of 水质 阿特拉津的测定 气相色谱法.

HJ 754-2015 — Warning. The solvents and reagents used in the experiment are all toxic. The sample preparation process should be carried out in a fume hood. Wear protective equipment as required to avoid contact with skin and clothing.

1 Scope of application this standard specifies the gas chromatographic method for the determination of atrazine in water. This standard applies to the determination of atrazine in surface water, groundwater, domestic sewage and industrial wastewater.

When the sample size is 100 ml, the detection limit of atrazine is 0.2 µg/L, and the lower limit of determination is 0.8 µg/L.

Found what you need?

Document preview — HJ 754-2015

National Standard of the People's Republic of China

Issued by: Ministry of Ecology and Environment

Contents

  • Foreword
  • 1 Water quality atrazine determination gas chromatography
  • 2 Normative references
  • 3 Principle of the method
  • 4 Reagents and materials
  • 4.5 Sodium chloride (NaCl)
  • 4.6 Anhydrous sodium sulfate (Na2SO4)
  • 5 Instruments and equipment
  • 6 Samples
  • 6.1 Sample collection and preservation
  • 6.2 Preparation of samples
  • 6.3 Preparation of blank samples
  • 7 Analysis steps
  • 7.1 Gas Chromatography Reference Conditions
  • 7.2 Establishing a calibration curve
  • 7.3 Sample determination
  • 7.4 Blank test
  • 8 Calculation and representation of results
  • 8.1 Qualitative analysis
  • 8.2 Quantitative analysis
  • 8.3 Result representation
  • 9 Precision and accuracy
  • 9.1 Precision
  • 9.2 Accuracy
  • 10 Quality Assurance and Quality Control
  • 11 Waste treatment

Foreword

To implement the Environmental Protection Law of the People's Republic of China and the Law of the People's Republic of China on Water Pollution Prevention and Control, to protect the environment, to ensure human health, standardize the determination method of atrazine in water, and develop this standard.

This standard specifies the gas chromatographic method for the determination of atrazine in water.

This standard is the first release.

This standard was formulated by the Science and Technology Standards Department of the Ministry of Environmental Protection.

This standard is mainly drafted by. Taizhou Environmental Monitoring Center Station.

This standard is verified by. Jiangsu Environmental Monitoring Center, Wuxi Environmental Monitoring Center Station, Suzhou Environmental Monitoring Center, Changzhou Environmental Monitoring Center, Zhenjiang Environmental Monitoring Center Station and Taizhou Environmental Monitoring Center Station.

This standard was approved by the Ministry of Environmental Protection on October 22, 2015.

This standard has been implemented since December 1, 2015.

This standard is explained by the Ministry of Environmental Protection.

1 Water quality atrazine determination gas chromatography

Warning. The solvents and reagents used in the experiment are all toxic. The sample preparation process should be carried out in a fume hood.

Wear protective equipment as required to avoid contact with skin and clothing.

1 Scope of application this standard specifies the gas chromatographic method for the determination of atrazine in water.

This standard applies to the determination of atrazine in surface water, groundwater, domestic sewage and industrial wastewater.

When the sample size is 100 ml, the detection limit of atrazine is 0.2 µg/L, and the lower limit of determination is 0.8 µg/L.

2 Normative references

The contents of this standard refer to the following documents or their terms. For undated references, the valid version is appropriate.

Used in this standard.

HJ/T 91 Surface Water and Wastewater Monitoring Technical Specifications HJ/T 164 Technical Specifications for Groundwater Environmental Monitoring

3 Principle of the method

The atrazine in the water is extracted with dichloromethane, and the extract is dried over anhydrous sodium sulfate, concentrated, and converted into acetone.

Agent, after constant volume, separated and detected by gas chromatograph-nitrogen phosphorus detector (NPD), qualitative according to retention time, external standard method Quantitative.

4 Reagents and materials

Unless otherwise stated, analytically pure reagents and laboratory water in accordance with national standards were used for the analysis.

4.1 Dichloromethane (CH2Cl2). pesticide residue grade.

4.2 Acetone (C3H6O). pesticide residue grade.

4.3 n-hexane (C6H14). pesticide residue grade.

4.4 Ethyl acetate (C4H8O2). pesticide residue grade.

4.5 Sodium chloride (NaCl)

It was fired in a muffle furnace at 400 ° C for 4 h, cooled and placed in a ground glass bottle and stored in a desiccator.

4.6 Anhydrous sodium sulfate (Na2SO4)

It was fired in a muffle furnace at 400 ° C for 4 h, cooled and placed in a ground glass bottle and stored in a desiccator.

4.7 Atrazine standard solution. rho = 100 mg/L, the solvent is acetone, commercially available.

4.8 Carrier gas. nitrogen, purity >=99.999%.

4.9 Combustion gas. hydrogen, purity >= 99.95%.

4.10 Gas-assisted gas. oil-free compressed air, purified by 5 Å molecular sieve.

5 Instruments and equipment

5.1 Gas Chromatograph. Nitrogen Phosphorus Detector (NPD).

5.2 Column. quartz capillary column, 30 m × 0.25 mm, coated with 5% phenylmethylpolysiloxane, film thickness 0.25 µm, 2 or other equivalent capillary column.

5.3 Auxiliary Qualitative Column. Quartz capillary column, 30 m × 0.25 mm, internally coated with 35% phenylmethylpolysiloxane, film thickness 0.25 µm, or other equivalent capillary column.

5.4 Concentration device. A device with comparable performance such as a nitrogen blow concentrator, a rotary evaporator or a KD concentrator.

5.5 separatory funnel. 250 ml.

5.6 Microinjectors. 10 µl, 50 µl and 100 µl.

5.7 Purification column. silica gel type adsorption column, 500 mg/6 ml, commercially available.

5.8 Common instruments and equipment used in general laboratories.

6 Samples

6.1 Sample collection and preservation

Samples were taken with reference to the relevant regulations of HJ/T 91 and HJ/T 164. Use 500 ml hard ground glass bottle or have poly four Samples are taken from the threaded glass bottle of the vinyl fluoride cover. The sample should be filled with the sample bottle and sealed, placed in a refrigerator at 4 °C.

Save inside. The sample should be extracted within 7 days after sampling.

6.2 Preparation of samples

6.2.1 Extraction

Take 100 ml of sample into a 250 ml separatory funnel (5.5), add 5 g of sodium chloride (4.5), dissolve and add 15 ml Dichloromethane (4.1), shaken for 5 min, allowed to stand for 15 min, layered, collected organic phase, repeated extraction, combined extraction the liquid was taken and dried over anhydrous sodium sulfate (4.6).

Note 1. If emulsification occurs during the extraction process, mechanical separation can be used to complete the two-phase separation, including agitation, centrifugation, and ultrasonic methods.

Demulsification, can also be used to break the milk by freezing.

6.2.2 Purification

For samples with complex compositions, the following purification method can be used. concentrate the extract (6.2.1) to near dry and then add positive About 1 ml of hexane is used for purification. Purification step. activate the purification column (5.7) with 10 ml of n-hexane (4.3), wait for the column when the hexane is nearly dry, the n-hexane concentrate is transferred to a purification column, and the concentrating tube is washed 2 to 3 times with 5 ml of n-hexane.

On the upper column, control the elution speed to about 2.5 ml/min (about 1 drop/s), discard the eluent; then use a 10 ml volume ratio of 9.1.

Elution with hexane and ethyl acetate (4.4) was carried out to control the elution rate to about 2.5 ml/min (about 1 drop/s), and the eluate was collected.

Note 2. The cleaner groundwater, surface water and domestic sewage extract (6.2.1) can be directly pressed (6.2.3) without purification steps.

The steps are processed.

6.2.3 Concentration and replacement of solvents

Concentrate the extract (6.2.1) or the purified eluent (6.2.2) with a concentration unit (5.4) and convert the solvent to acetone.

(4.2), make up to 1.0 ml. The samples were stored in a 4 ° C refrigerator and analyzed within 40 d.

6.3 Preparation of blank samples

While analyzing the sample, take 100 ml of experimental water instead of the sample, follow the same procedure as the preparation of the sample (6.2).

A blank sample was prepared.

7 Analysis steps

7.1 Gas Chromatography Reference Conditions

Inlet temperature. 240 ° C, split injection, split ratio 10.1; oven temperature. initial temperature 40 ° C, keep 3 3 min, rise to 190 ° C at 30 ° C/min, hold for 5 min, then increase to 250 ° C at 30 ° C/min, keep 5 min; carrier gas flow rate. 1.0 ml/min; detector temperature. 300 ° C, hydrogen flow rate. 3.0 ml/min, air flow rate. 60.0 Ml/min; injection volume. 1.0 µl.

7.2 Establishing a calibration curve

Take 5 5.0 ml volumetric flasks, add appropriate amount of acetone (4.2), and add 5.0 with a micro-syringe (5.6).

Ll, 10.0 µl, 20.0 µl, 40.0 µl, 100.0 µl of atrazine standard solution (4.7), make up to volume with acetone (4.2), and mix.

The concentration of atrazine was 0.10 mg/L, 0.20 mg/L, 0.40 mg/L, 0.80 mg/L, 2.00 mg/L, respectively.

Standard series. The concentration of the standard series (mg/L) is plotted on the abscissa, and the corresponding peak area (or peak height) of the chromatogram is vertical.

Coordinates, establish a standard curve.

7.3 Sample determination

The sample was treated according to the preparation method (6.2) of the sample, and then measured according to the gas chromatography reference condition (7.1).

Note 3. When the actual sample concentration exceeds the calibration curve range, dilute the sample to the linear range of the calibration curve before sample preparation (6.2) and determination.

7.4 Blank test

The prepared blank sample (6.3) was measured according to the same instrumental analysis conditions as the standard curve.

8 Calculation and representation of results

8.1 Qualitative analysis

The target compound is characterized based on the retention time of the target in the sample and the target in the standard series.

The retention time window t±3S was established before sample analysis. t is the retention of the target compound at each concentration level at the initial calibration Time average, S is the standard deviation of the retention time of the target compound at each concentration level at the initial calibration. Target analysis the compound should peak within the retention time window. The gas chromatogram of atrazine is shown in Figure 1 under the reference chromatographic conditions of this standard.

Figure 1 Gas chromatogram of atrazine (2.0 mg/L)

Note 4. If atrazine is detected in the sample, it can be confirmed using an auxiliary qualitative column (5.3) or GC-MS assisted qualitative determination.

8.2 Quantitative analysis

Calculate the mass concentration (µg/L) of atrazine in the sample according to formula (1) using the external standard curve method.

100011 xx=

In the formula.

rho--the mass concentration of atrazine in the sample, µg/L;

4rho1--calculate the mass concentration of atrazine in the sample according to the standard curve, mg/L;

V--sample sampling volume, ml V1--The concentration of the extract after concentration is adjusted to ml.

8.3 Result representation

When the measurement result is greater than or equal to 100 µg/L, the result retains three significant figures; when less than 100 µg/L, the result is guaranteed.

Leave one decimal place.

9 Precision and accuracy

9.1 Precision

Six laboratories tested a uniform sample of atrazine at 1.00 µg/L, 10.0 µg/L, and 18.0 µg/L.

The relative standard deviations in the laboratory are. 4.1% ~ 6.7%, 3.1% ~ 6.1%, 2.0% ~ 3.3%; interlaboratory phase the standard deviations were. 5.5%, 3.3%, and 1.3%; the repeatability limits were. 0.30 µg/L, 1.34 µg/L, and 1.41 µg/L, respectively;

Reproducibility limits were. 0.40 µg/L, 1.53 µg/L, and 1.44 µg/L, respectively.

9.2 Accuracy

The blank samples were spiked in 6 laboratories, and the scalar weights were 0.20 µg, 1.00 µg, and 1.80 µg, respectively.

The recoveries of spiked standards were. 85.5%~111%, 88.5%~108%, 88.3%~102%; the final value of spiked recovery was 95.2% ± 6.6%, 96.5% ± 3.6%, 96.3% ± 1.8%.

Six laboratories performed spiked measurements on surface water, industrial wastewater and domestic sewage, respectively. The scalar weight was 0.05.

Gg, 0.50 µg, 1.80 µg, the recoveries of standard addition are. 81.2%~104%, 75.6%~105%, 78.9%~105%;

The final recovery values were 92.9% ± 6.0%, 88.3% ± 8.8%, and 94.4% ± 8.0%.

10 Quality Assurance and Quality Control

10.1 At least one blank sample shall be made for each batch of samples, and the blank value shall be lower than the method detection limit. Otherwise, the cause should be ascertained.

10.2 The correlation coefficient of the standard curve should be >= 0.995, otherwise the standard curve should be redrawn.

10.3 Continuous calibration. For every 20 samples measured, a standard solution of the concentration of the intermediate point of a standard curve shall be determined, and the measurement result the relative error of this point concentration with the standard curve should be <= 20%, otherwise the standard curve should be redrawn.

10.4 Each batch of samples shall be tested for at least 10% of parallel samples. When the number of samples is less than 10, at least one parallel double shall be determined.

kind. When the measurement result is within 10 times the detection limit (including the detection limit of 10 times), the relative deviation of the results of the parallel double sample determination should be <= 30%; when the measurement result is greater than 10 times the detection limit, the relative deviation of the parallel double sample measurement results should be <= 20%.

10.5 At least one spiked sample shall be determined for each batch of samples, and the spiked recovery rate shall be between 70% and 120%.

11 Waste treatment

The organic waste generated in the experiment should be stored in a centralized manner and entrusted to qualified units for processing.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

How to Download HJ 754-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

HJ 754-2015

$225.00