HJ 538-2009Stationary source emission. Determination of lead. Flame atomic absorption spectrometry (English PDF)

固定污染源废气 铅的测定 火焰原子吸收分光光度法(暂行)

Preview PDF

This is a limited preview

Buy now to download the full PDF (6 pages)

Need quotation for your management?

Get a formal quotation for HJ 538-2009 in 30 minutes.

Issued by

Ministry of Ecology and Environment

Level / Type

National · Mandatory

Issue date

December 30, 2009

Implementation date

April 1, 2010

Scope

HJ 538-2009 is the English-translated version of 固定污染源废气 铅的测定 火焰原子吸收分光光度法(暂行).

HJ 538-2009 — This standard specifies the flame atomic absorption spectrophotometric method for the determination of lead in exhaust gas from stationary sources.

This standard applies to the determination of lead in fixed source pollution. The detection limit of the method is 5 µg/50 ml sample solution. When the sampling volume is 400 L, the detection limit is 0.013 mg/m3, and the lower limit of determination is 0.052 mg/m3.

Found what you need?

Document preview — HJ 538-2009

National Standard of the People's Republic of China

Classification
Z 25

Issued by: Ministry of Ecology and Environment

Contents

  • Foreword
  • 1 Scope of application
  • 2 Normative references
  • 3 Principle of the method
  • 4 Interference and elimination
  • 5 Reagents and materials
  • 6 Instruments and equipment
  • 7 Samples
  • 7.1 Sample collection
  • 7.2 Preservation of samples
  • 7.3 Preparation of samples
  • 7.4 Preparation of blank samples
  • 8 Analysis steps
  • 8.1 Atomic absorption spectrophotometer working conditions
  • 8.2 Drawing of standard curve
  • 8.3 Preparation of samples
  • 8.4 Determination of sample
  • 9 Calculation of results
  • 10 Quality Assurance and Quality Control

Foreword

To protect the environment and protect people in order to implement the Environmental Protection Law of the People's Republic of China and the Law of the People's Republic of China on the Prevention and Control of Air Pollution this standard is formulated for the health monitoring and monitoring methods for the determination of lead in waste gas from fixed sources.

This standard specifies the flame atomic absorption spectrophotometric method for the determination of lead in exhaust gas from stationary sources.

This standard was formulated by the Science and Technology Standards Department of the Ministry of Environmental Protection.

This standard was drafted. Beijing Environmental Protection Monitoring Center.

This standard was approved by the Ministry of Environmental Protection on December 30, 2009.

This standard has been implemented since April 1, 2010.

This standard is explained by the Ministry of Environmental Protection.

Determination of lead in fixed pollution source Flame atomic absorption spectrophotometry (provisional)

1 Scope of application

This standard specifies the flame atomic absorption spectrophotometric method for the determination of lead in exhaust gas from stationary sources.

This standard applies to the determination of lead in fixed source pollution.

The detection limit of the method is 5 µg/50 ml sample solution. When the sampling volume is 400 L, the detection limit is 0.013 mg/m3, and the lower limit of determination is 0.052 mg/m3.

2 Normative references

The contents of this standard refer to the following documents or their terms. For undated references, the valid version applies to this standard.

GB/T 16157 Determination of particulate matter in fixed pollution source exhaust gas and sampling method of gaseous pollutants HJ/T 373 Technical Specifications for Quality Assurance and Quality Control of Fixed Pollution Source Monitoring (Trial) GB/T 6682 Analytical laboratory water specifications and test methods

3 Principle of the method

The exhaust gas sample is collected by a quartz fiber filter cartridge, digested to prepare a sample solution, and the lead solution in the sample solution is determined by an atomic absorption spectrophotometer.

concentration.

4 Interference and elimination

Fe3, A13, Be3, Cr3, Cd2, Cu2, Zn2, Co2, Hg2, Sn2, Mn2, Mg2, Ag over 100 times lead the plasma does not interfere with the measurement and SiO32- is slightly disturbed. Na, K, and Ca2 are slightly sensitized. When the concentration is high, the dilution method can be used.

Eliminate interference.

5 Reagents and materials

Unless otherwise stated, analytically pure reagents that meet national standards were used for the analysis; experimental water, GB/T 6682, grade 2.

5.1 Nitric acid. rho (HNO3) = 1.42 g/ml, excellent grade pure.

5.2 Perchloric acid. rho (HClO4) = 1.67 g/ml, excellent grade pure.

5.3 Hydrogen peroxide. w (H2O2) = 30%, excellent grade pure.

5.4 Nitric acid solution. phi (HNO3) = 1%.

Formulated with nitric acid (5.1).

5.5 Nitric acid solution. 1 1.

Formulated with nitric acid (5.1).

5.6 Lead standard stock solution. rho (Pb) = 1.00 mg/ml.

Weigh 0.500 0 g of metal lead (99.99%) in a 100 ml beaker and dissolve it with 15 ml of (1 1) nitric acid solution (5.5). After cooling, Transfer to a 500 ml volumetric flask and dilute to the mark with water.

Commercially available certified standard solutions can also be used as lead standard stock solutions.

5.7 Lead standard use solution. rho (Pb) = 100 µg/ml.

The lead standard stock solution (5.6) was diluted with 1% HNO3 (5.4) to a standard stock solution containing 100 µg lead per ml.

5.8 Acetylene. The purity is not less than 99.6%.

6 Instruments and equipment

Unless otherwise stated, Class A glassware in accordance with national standards was used for the analysis.

6.1 Smoke sampler. The flow range is 5~50 L/min.

6.2 Quartz fiber filter cartridge.

Note. If the filter cartridge blank value is high, it can be soaked with hot (1 1) nitric acid solution (5.5) for about 3 h before use (can not be boiled, so as not to damage the filter cartridge). From acid After taking out, soak it in water for 10 min, remove it with water and wash it to near neutrality. After drying, it can be used.

6.3 Atomic absorption spectrophotometer.

6.4 Electric heating plate.

7 Samples

7.1 Sample collection

Sample collection was performed in accordance with GB/T 16157. When the temperature is below 400 °C, it is sampled at the same speed in the pipeline. When the temperature is higher than 400 ° C, lead in the presence of gas, the exhaust gas should be led out of the pipeline to lower the temperature to below 400 °C, and sample at a constant flow of 20 L/min for 10 to 30 minutes.

7.2 Preservation of samples

After the sample of the filter cartridge is collected, the seal is folded inward, placed vertically in the original sampling box, and placed in a desiccator for storage.

7.3 Preparation of samples

Cut the filter cartridge into small pieces, place in a 250 ml Erlenmeyer flask, add (1 1) nitric acid solution (5.5) 50 ml and 30% hydrogen peroxide (5.3) 15 ml immersion sample filter cartridge, the bottle mouth was inserted into a small funnel, heated to a slight boiling on the hot plate, and kept slightly boiling for 2 h. Carefully add 30% after cooling Hydrogen peroxide (5.3) 5 ml, if necessary, add a small amount of water, then heat on a hot plate to a slight boiling, keep boiling for 1 h. Filter after cooling, the filtrate was filtered into a beaker, and the conical flask and the filter residue were washed three times with water, and the washing liquid was combined with the filtrate. Place the beaker containing the filtrate on the hot plate on the top, the filtrate is steamed to near dry (the evaporation temperature should not be too high to avoid splashing), then add (1 1) nitric acid solution (5.5) 2 ml, heat to make the residue was dissolved. After cooling, the solution was transferred to a 50 ml volumetric flask and diluted with water to the mark.

7.4 Preparation of blank samples

Take two blank cartridges of the same batch number, and simultaneously process the sample to prepare a blank sample.

8 Analysis steps

8.1 Atomic absorption spectrophotometer working conditions

Instrument parameters can be selected by referring to the instruction manual. The conditions and parameters listed below are for reference.

Wavelength. 283.3 nm; slit width. 0.8 nm; lamp current. 5 mA; flame type. air-acetylene; gas flow. acetylene

2.1 L/min, air 8.0 L/min; burner height. 10.0 cm.

8.2 Drawing of standard curve

8.2.1 Preparation of standard solutions

Take 7 50 ml volumetric flasks and prepare lead standard series according to Table 1. Dilute to the mark with 1% nitric acid solution (5.4) and shake well.

Table 1 Lead Standard Series

Bottle number 0 1 2 3 4 5 6 Lead standard use solution/ml 0 0.50 1.00 2.00 3.00 4.00 5.00 Lead concentration/(µg/ml) 0.00 1.00 2.00 4.00 6.00 8.00 10.0

8.2.2 Drawing a standard curve

The absorbance of the lead standard series is determined according to the selected instrument operating conditions, and the linear regression equation of the standard curve is calculated.

8.3 Preparation of samples

Take an appropriate amount of the sample solution in a 50 ml volumetric flask and dilute to the mark with a 1% nitric acid solution (5.4). A blank sample was prepared by the same method.

8.4 Determination of sample

The absorbance of the sample and the blank sample was determined by the working conditions of the instrument plotted according to the standard curve.

9 Calculation of results

According to the measured absorbance value, the concentration of lead in the sample and the blank sample was calculated from the linear regression equation, and the solid was calculated by the formula (1).

The concentration of lead in the exhaust gas of the pollution source.

rho (Pb)= 1 0 t

Nd a

( ) 50 V

rho rho- × × (1)

Where. rho(Pb)--the mass concentration of lead in the fixed source exhaust gas, mg/m3;

rho1-- the concentration of lead in the sample solution, µg/ml;

rho0--the average value of lead mass concentration in the blank sample, µg/ml;

50--sample solution volume, ml;

Vt--the total volume of the sample solution, ml;

Va--the volume of the sample solution taken during the measurement, ml;

Vnd - the sampling volume of dry gas in the standard state (101.325 kPa, 273 K), L.

10 Quality Assurance and Quality Control

Execute according to the relevant regulations of HJ/T 373.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.

Referenced standards

How to Download HJ 538-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
6 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

HJ 538-2009

$120.00