HJ 38-2017Stationary Source Emission - Determination of Total Hydrocarbons, Methane and Nonmethane Hydrocarbons - Gas Chromatography (English PDF)
Also coversHJ38-2017
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for HJ 38-2017 in 30 minutes.
Issued by
Ministry of Environmental Protection of the People’s Republic of China
Level / Type
National · Mandatory
Issue date
December 29, 2017
Implementation date
April 1, 2018
Scope
HJ 38-2017 (Stationary Source Emission - Determination of Total Hydrocarbons, Methane and Nonmethane Hydrocarbons - Gas Chromatography) is available as an English-translated PDF.
HJ 38-2017 is the Chinese standard "Stationary Source Emission - Determination of Total Hydrocarbons, Methane and Nonmethane Hydrocarbons - Gas Chromatography".
Its scope clause reads: This Standard specifies the gas chromatography method of determining total hydrocarbons, methane and nonmethane hydrocarbons in exhaust gas emitted from stationary sources.
This Standard is applicable to the determination of total hydrocarbons, methane and nonmethane hydrocarbons in organized emission of exhaust gas from stationary sources.
When the sample injection volume is 1.0 mL, the detection limits of total hydrocarbons and methane determined by this method are 0.06 mg/m3 (calculated by methane), and the lower limits are 0.24 mg/m3 (calculated by methane); the detection limit of nonmethane hydrocarbons is 0.07 mg/m3 (calculated by carbon), and the lower limit is 0.28 mg/m3 (calculated by carbon).
Its clauses include terms and definitions; method and principle; reagents and materials; instruments and equipment; sample; analytical procedures; result calculation and expression.
It was issued by the Ministry of Environmental Protection of the People’s Republic of China on 2017-12-29 and took effect on 2018-04-01.
Found what you need?
Document preview — HJ 38-2017
National Standard of the People's Republic of China
Issued by: Ministry of Environmental Protection of the People’s Republic of China
Contents
- Republic of China...3
- Foreword...5
- 1 Scope...7
- 2 Normative References...7
- 3 Terms and Definitions...7
- 4 Method and Principle...8
- 5 Reagents and Materials...8
- 6 Instruments and Equipment...9
- 7 Sample...11
- 8 Analytical Procedures...12
- 9 Result Calculation and Expression...15
- 10 Precision and Accuracy...16
- 11 Quality Assurance and Quality Control...17
- 12 Precautions...18
1 Scope
This Standard specifies the gas chromatography method of determining total hydrocarbons, methane and nonmethane hydrocarbons in exhaust gas emitted from stationary sources.
This Standard is applicable to the determination of total hydrocarbons, methane and nonmethane hydrocarbons in organized emission of exhaust gas from stationary sources.
When the sample injection volume is 1.0 mL, the detection limits of total hydrocarbons and methane determined by this method are 0.06 mg/m3 (calculated by methane), and the lower limits are 0.24 mg/m3 (calculated by methane); the detection limit of nonmethane hydrocarbons is 0.07 mg/m3 (calculated by carbon), and the lower limit is
0.28 mg/m3 (calculated by carbon).
2 Normative References
This Standard quotes the following documents or clauses in the documents. In terms of references without a specified date, the valid version applies to this Standard.
GB/T 16157 The Determination of Particulates and Sampling Methods of Gaseous
Pollutants Emitted from Exhaust Gas of Stationary Source
HJ 732 Emission from Stationary Sources - Sampling of Volatile Organic Compounds
- Bags Method
HJ/T 397 Technical Specifications for Emission Monitoring of Stationary Source
3 Terms and Definitions
The following terms and definitions are applicable to this Standard.
3.1 Total Hydrocarbons (THC)
Total hydrocarbons refer to the sum of gaseous organic compounds that respond on the hydrogen flame ionization detector of the gas chromatograph under the determination conditions specified in this Standard.
4 Method and Principle
Directly inject gas sample into a gas chromatograph equipped with a hydrogen flame ionization detector; respectively determine the content of total hydrocarbons and methane on the total hydrocarbon column and the methane column.
5 Reagents and Materials
Unless it is otherwise specified, analytically pure chemical reagents and distilled water that meet the national standards shall be used for analysis.
5.1 De-hydrocarbon air. content of total hydrocarbons (oxygen peak included) <= 0.40
mg/m3 (calculated by methane); or, determine on the methane column, no other peaks except the oxygen peak.
5.3 Nitrogen. purity >= 99.999%.
5.4 Hydrogen. purity >= 99.99%.
5.5 Air. use a purification tube for air purification.
6 Instruments and Equipment
6.1 Sampling container. all-glass syringe, with a volume not less than 100 mL; clean and dry it, then, save it for later use. The air bag material shall comply with the relevant stipulations of HJ 732; the volume shall be not less than 1 L; before use, use de- hydrocarbon air (5.1) to clean it for at least 3 times.
6.3 Sample storage box. with light-proof function.
6.4 Gas chromatograph. equipped with hydrogen flame ionization detector.
6.5 Sample injector. an injection valve with a 1 mL sample quantitative loop, or, a 1 mL gas-tight glass syringe.
6.6 Chromatographic column
6.7 Sample heating device. the sample can be placed in it and heated to not lower than
120 °C; the temperature control accuracy is ± 5 °C.
7 Sample
7.1 Sample Collection
7.1.1 Collection with air bag
In accordance with Figure 1, connect the sampling device. The determination of the sampling location, sampling point, sampling frequency and sampling time of exhaust gas emitted from stationary sources, as well as the determination of exhaust parameters and the sampling operations shall comply with the relevant stipulations of
GB/T 16157, HJ/T 397 and HJ 732.
7.1.2 Collection with glass syringe
In accordance with Figure 2, connect the sampling device. The determination of the sampling location, sampling point, sampling frequency and sampling time of exhaust gas emitted from stationary sources, as well as the determination of exhaust parameters and the sampling operations shall comply with the relevant stipulations of
GB/T 16157 and HJ/T 397.
7.2 Transportation of Blank Sample
Bring the sampling container filled with de-hydrocarbon air (5.1) to the sampling site.
Send it back to the laboratory for analysis together with the samples collected in the same batch.
7.3 Sample Storage
The glass syringe for sample collection shall be handled with care to prevent it from being damaged. Maintain the needle tip downwards and place it in the sample storage box for storage and transportation.
8 Analytical Procedures
8.1 Reference Conditions of Chromatographic Analysis
8.2 Calibration
8.2.1 Preparation of calibration series
Take a 100 mL glass syringe (beforehand, put in a piece of rigid polytetrafluoroethylene sheet) or a 1 L air bag as a container.
8.2.2 Draw a calibration curve
From low concentration to high concentration, respectively draw 1.0 mL of the calibration series (8.2.1); inject it into the gas chromatograph (6.4) to respectively determine total hydrocarbons and methane. Take the concentration of total hydrocarbons and methane (µmol/mol) as the x-coordinate; take the corresponding peak area as the y-coordinate; respectively a calibration curve of total hydrocarbons and methane.
8.2.3 Standard chromatogram
Under the reference conditions (8.1) of chromatographic analysis provided in this
8.3 Sample Determination
8.3.1 Determination of total hydrocarbons and methane
Take 1.0 mL of the sample to be tested. In accordance with the same operating steps and analysis conditions as the calibration curve, determine the peak area of total hydrocarbons and methane in the sample.
8.3.2 Determination of oxygen peak area
Take 1.0 mL of the de-hydrocarbon air (5.1). In accordance with the same operating steps and analysis conditions as the calibration curve, determine the oxygen peak area on the total hydrocarbon column.
9 Result Calculation and Expression
9.1 Result Calculation
The mass concentration of total hydrocarbons and methane in the sample shall be calculated in accordance with Formula (1).
9.2 Result Expression
When the determined result is less than 1 mg/m3, it shall be retained to two decimal places; when the determined result is greater than or equal to 1 mg/m3, 3 significant figures shall be retained.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Referenced standards
How to Download HJ 38-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16157-1996 — Determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source
HJ/T 397-2007 — Technical specifications for emission monitoring of stationary source
HJ 212-2025 — Technical requirements for data transmission of pollutant automatic monitoring and surveillance systems
Secure payment via Stripe
Payments accepted
HJ 38-2017
$100.00