GY/T 194-2003Specifications and methods of measurement on optical node used in CATV systems (English PDF)
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for GY/T 194-2003 in 30 minutes.
Issued by
State Administration of Radio and Television
Level / Type
National · Recommended
Issue date
October 13, 2003
Implementation date
December 1, 2003
Scope
GY/T 194-2003 (Specifications and methods of measurement on optical node used in CATV systems) is available as an English-translated PDF.
GY/T 194-2003 — This standard specifies the technical requirements and measurement methods for optical workstations in cable television systems. For tasks that ensure the same measurement uncertainty any equivalent measurement method can also be used.
In case of dispute, this standard shall prevail. This standard applies to the development, production, use, operation and maintenance of optical workstations for cable television systems.
Found what you need?
Document preview — GY/T 194-2003
National Standard of the People's Republic of China
- ICS
- 33.160
- Classification
- M 74
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Technical requirements
- 4.1 General requirements
- 4.2 Technical requirements
- 6 Output optical power stability dB ± 1.5-
- 7 Link flatness dB ± 1.5
- 8 RF input reflection loss dB >=16-
- 9 RF input impedance ohm 75-
- 10 Optical connector form-FC/APC or SC/APC-
- 11 Optical connector form-SC/APC or FC/APC
- 12 Noise power ratio dynamic range a dB
Foreword
This standard is based on the needs of China 's cable television network construction and operation, and refers to the performance parameters of optical workstations at home and abroad.
The technical requirements and measurement methods of the uplink optical transmitter are specified. The technical requirements and measurement methods of its downstream optical receiver are mainly referenced GB/T 11318.1-1996 "Cable distribution system equipment and components for television and sound signals-Part 1. General specifications" and GY/T 143-2000 "Technical Conditions and Measurement Methods for Amplifier Optical Transmitters and Receivers in Cable TV Systems". In the development of this standard, a comprehensive analysis A large number of test data and the specific requirements for the application of cable television systems. At the same time, both the advanced requirements and the production costs are taken into account in the index requirements.
The need for this and use.
Appendix A to this standard is an informative appendix.
This standard is under the jurisdiction of the National Radio and Television Standardization Technical Committee.
This standard was drafted. Radio and Television Metrology and Testing Center of the State Administration of Radio, Film and Television, Wuxi Lutong Electronic Technology Co., Ltd., Sichuan Jiuzhou Electronic Technology Co., Ltd.
1 Scope
This standard specifies the technical requirements and measurement methods for optical workstations in cable television systems. For tasks that ensure the same measurement uncertainty any equivalent measurement method can also be used. In case of dispute, this standard shall prevail.
This standard applies to the development, production, use, operation and maintenance of optical workstations for cable television systems.
2 Normative references
The clauses in the following documents have become the clauses of this standard after being referenced. For dated references, all subsequent Neither amendments (excluding errata) or revised versions are applicable to this standard, however, parties who have reached an agreement under this standard are encouraged to study is the latest version of these files available? For undated references, the latest version applies to this standard.
GB 5465.2-1985 Graphical symbols for electrical equipment GB/T 11318.1-1996 Cable and distribution system equipment and components for television and sound signals-Part 1. General specifications GY/T 143-2000 Cable TV system AM optical transmitter and receiver technical conditions and measurement methods
3 Terms and definitions
The following terms and definitions apply to this standard.
Return optical transmitter an optical transmitter that transmits an uplink transmission signal.
Forward optical receiver Optical receiver for receiving downlink transmission signals.
Return optical receiver Optical receiver for receiving uplink transmission signals.
Optical node
A transmission device with functions such as a downlink optical receiver and an uplink optical transmitter.
Noise power ratio (NPR) the total power (or power spectrum) of the digital modulation signal output by the uplink optical receiver within the specified temperature, specified link loss and return bandwidth the ratio of the density) to the total noise power (or power spectral density) within the return bandwidth is expressed in decibels.
Noise power ratio dynamic range when the noise power ratio is not less than a specified value within the specified temperature, specified link loss, and return bandwidth, it is added to the upstream optical transmitter the decibel difference between the maximum and minimum total power of the digitally modulated signal.
4 Technical requirements
4.1 General requirements
The appearance should be tidy, the surface should not have obvious dents, scratches, cracks, burrs, deformation; the coating should not be blistering, cracking and falling off;
The metal parts should not be rusted and damaged; the pouring material should not spill. The structure and components of the whole machine should be fastened without looseness; text symbols and graphics to explain the function Symbols and signs shall be complete, correct, clear and firm; graphic symbols shall comply with the relevant provisions of GB 5465.2-1985.
4.2 Technical requirements
4.2.1 Technical Requirements of Downlink Optical Receiver
Should comply with the relevant provisions of GY/T 143-2000.
4.2.2 Technical Requirements for Uplink Optical Transmitters
See Table 1.
Table 1 Technical requirements for uplink optical transmitters
Remarks on technical indicators of project unit
1 Laser type-DFB laser FP laser-1310 ± 20-
2 Output light wavelength nm 1550 ± 10-
3 Output optical power dBm >=-3-
4 RF input frequency range MHz 5 ~ 65-
5 RF input signal level dBµV 75 ~ 85 refers to the total power added to the upstream RF signal input port of the optical workstation.
6 Output optical power stability dB ± 1.5-
7 Link flatness dB ± 1.5
Refers to uplink optical transmitter and uplink Optical receiver and other links index.
8 RF input reflection loss dB >=16-
9 RF input impedance ohm 75-
10 Optical connector form-FC/APC or SC/APC-
Noise power ratio (NPR) Dynamic Range dB >=15 (NPR>=30dB) >=10 (NPR>=30dB) Refers to uplink optical transmitter and uplink Optical receiver and other links index.
4.2.3 Technical Requirements of Uplink Optical Receiver See Appendix A of this standard.
4.3 Environmental condition requirements
4.3.1 Environmental requirements for downlink optical receivers should comply with the relevant provisions of 5.3.2.2 of GY/T 143-2000.
4.3.2 Environmental requirements for uplink optical transmitters should comply with the relevant provisions of 4.3 in GB/T 11318.1-1996.
4.4 Security requirements should comply with the relevant provisions of 4.5 in GB/T 11318.1-1996.
4.5 EMC requirements should comply with the relevant provisions of 4.6 of GB/T 11318.1-1996.
5 Measurement method
5.1 Measuring equipment
5.1.1 Spectrum Analyzer Operating wavelength range. 1280nm ~ 1570nm;
Wavelength resolution. 30dB;
Stability. better than ± 0.1dB;
Light reflection loss at each end. > 50dB.
5.1.4 Network Analyzer Impedance. 75ohm;
Operating frequency range. 1MHz ~ 1000MHz;
Measurement accuracy of flatness. 50dB.
5.1.9 Notch filter
Impedance. 75ohm;
Technical parameter chart. See Figure 1.
Figure 1 Technical parameters of the notch
5.2 Measurement of output light wavelength
5.2.1 Measurement block diagram See Figure 2.
Figure 2 Block diagram of output optical wavelength measurement of uplink optical transmitter
5.2.2 Measurement procedure
a) Connect the measurement equipment as shown in Figure 2;
b) Set the wavelength and scan width of the spectrum analyzer;
c) At 25 ° C ± 5 ° C, adjust the measured wavelength to the middle of the screen from left to right and up to the reference position. Read directly with cursor Take the output optical wavelength value of the upstream optical transmitter.
5.3 Measurement of output optical power and output optical power stability
5.3.1 Measurement block diagram See Figure 3.
Uplink optical transmitter optical power meter Optical Spectrum Transmitter
Figure 3 Measurement block diagram of uplink optical transmitter output optical power and output optical power stability
5.3.2 Measurement procedure
a) Connect the measurement equipment as shown in Figure 3;
b) adjust the receiving light wavelength of the optical power meter to the working wavelength of the upstream optical transmitter;
c) Read the output optical power of the upstream optical transmitter directly from the optical power meter at 25 °C ± 5 °C, and record it as A (dBm);
d) Place the upstream optical transmitter in a high and low temperature constant temperature test box, and keep it at -25 °C and + 55 °C for 2h, then from the optical power meter Read the output optical power of the uplink optical transmitter at -25 ° C and + 55 ° C, and record them as B (dBm) and C (dBm), respectively.
e) Take the larger absolute value of BA and CA, which is the output optical power stability at -25 ° C and + 55 ° C.
5.4 Link flatness measurement
5.4.1 Measurement block diagram See Figure 4.
Network Analyzer Uplink Optical Receiver Variable Optical Attenuator Uplink Optical Transmitter
Figure 4 Block diagram of link flatness measurement
5.4.2 Measurement procedure
a) Set the corresponding parameters of the network analyzer, connect the input and output of the network analyzer, and calibrate the network analyzer;
b) Connect the measurement equipment as shown in Figure 4;
c) Measure the flatness of the link on the network analyzer.
5.5 Measurement of RF input reflection loss
5.5.1 Measurement block diagram See Figure 5.
Uplink Optical Transmitter Network Analyzer
Figure 5 Measurement block diagram of RF input reflection loss of uplink optical transmitter
5.5.2 Measurement procedure
a) Set the corresponding parameters of the network analyzer and calibrate the network analyzer;
b) Connect the measurement equipment as shown in Figure 5;
c) Select the maximum reflection value in the operating frequency range on the network analyzer, and its absolute value is the RF input reflection loss of the upstream optical transmitter Consuming.
5.6 Measurement of Noise Power Ratio (NPR) Dynamic Range
5.6.1 Measurement block diagram See Figure 6.
Spectrum analysis
Analyzer
Upward light
Receiver
Variable light
Attenuator
10km
optical fiber
Upward light
Sender
Notch
5MHz ~ 65MHz
Bandpass filter
Wideband white noise Sound generator
Figure 6 Block diagram of noise-to-power ratio dynamic range measurement
5.6.2 Measurement procedure
a) Connect the measurement equipment as shown in Figure 6;
b) adjust the variable optical attenuator so that the uplink optical link loss is 5dB;
c) Adjust the output power of the broadband white noise generator according to the RF excitation power requirements of the upstream optical transmitter, the RF excitation power of the sender starts from 25dB below the nominal excitation power and gradually increases in 2dB steps until it is higher than the nominal excitation power.
Power 15dB;
d) use a spectrum analyzer to measure the NPR at the output of the upstream optical receiver point by point;
e) Using NPR as the ordinate and excitation power as the abscissa, draw the relationship between NPR and input excitation power
f) Find out the dynamic range value from the curve within the specified NPR range.
Appendix A
(Informative appendix) Technical requirements for uplink optical receiver the technical requirements of the upstream optical receiver are shown in Table A.1.
Table A.1 Technical requirements for uplink optical receivers
Technical Index of Project Unit
1 Input optical power range dBm -15.0 ~ 1.0
2 Light reflection loss dB >=45
3 Nominal light wavelength nm 1310, 1550 or double window
4 Output frequency range MHz 5 ~ 65
5 RF output signal level dBµV Product specification
6 Link flatness a dB ± 1.5
7 Optical automatic gain control range dB Product specification
8 RF output reflection loss dB >=16
9 RF output level stability dB ± 3.0 (-25 °C ~ 55 °C)
10 Output impedance ohm 75
11 Optical connector form-SC/APC or FC/APC
12 Noise power ratio dynamic range a dB
>=15 (NPR>=30dB)
Optical transmitter uses DFB laser >=10 (NPR>=30dB) Optical transmitter using FP laser a The link flatness and the dynamic range of the noise power ratio are the link indicators composed of the uplink optical transmitter and uplink optical receiver.
references
[1] GY/T 180-2001 Technical specification of physical channel for uplink transmission of HFC network [2] IEC 60728-4 Cable and distribution system equipment and components for television and sound signals. Part 4. Upstream broadband coaxial cable device
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
Referenced standards
How to Download GY/T 194-2003
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 11318.1-1996 — Equipments and components used in cabled distribution systems primarily intended for television and sound signals--Part 1:Generic specifications
GY/T 182-2026 — Operation and maintenance regulations for satellite digital broadcasting earth station
GY/T 426-2026 — Technical requirements and measurement methods for emergency broadcasting active release terminal
Secure payment via Stripe
Payments accepted
GY/T 194-2003
$264.00