GBZ/T 315-2018Determination of chromium in blood -- Graphite furnace atomic absorption spectrometric method (English PDF)

血中铬的测定 石墨炉原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (6 pages)

Need quotation for your management?

Get a formal quotation for GBZ/T 315-2018 in 30 minutes.

Issued by

National Health and Family Planning Commission

Level / Type

National · Recommended

Issue date

August 16, 2018

Implementation date

January 1, 2019

Scope

GBZ/T 315-2018 is the English-translated version of 血中铬的测定 石墨炉原子吸收光谱法.

GBZ/T 315-2018 — This standard specifies graphite furnace atomic absorption spectrometry for the determination of chromium in blood. This standard applies to the determination of chromium in the blood of occupational contacts.

Found what you need?

Document preview — GBZ/T 315-2018

National Standard of the People's Republic of China

Classification
C 60
Replacing
WS/T 38-1996

Issued by: National Health and Family Planning Commission

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Principle
  • 4 Instruments
  • 5 Reagent
  • 6 Sample collection, transportation and storage
  • 7 Analysis steps
  • 7.1 Instrument Operation Reference Conditions
  • 7.2 Sample Pretreatment
  • 7.3 Preparation and determination of the working curve
  • 7.4 Determination
  • 8 Calculation
  • 9 Description

Foreword

This standard is formulated in accordance with the Law of the People's Republic this standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard replaces WS/T 38-1996 "Method for the determination of chromium in blood by graphite furnace atomic absorption spectrometry".

Compared with WS/T 38-1996, the main changes are as follows.

-- The operating conditions of the instrument are changed to the reference conditions for instrument operation;

-- Improved standard formulation and sample handling methods;

-- Increased use of matrix modifiers.

This standard was drafted. Jiangsu Provincial Center for Disease Control and Prevention, China Center for Disease Control and Prevention, Occupational Health and Poison Control Institute, Guangdong Provincial Occupational Disease Prevention and Control Institute, Wuxi Municipal Center for Disease Control and Prevention, Nanjing Occupational Disease Prevention and Control Institute.

1 Scope

This standard specifies graphite furnace atomic absorption spectrometry for the determination of chromium in blood.

This standard applies to the determination of chromium in the blood of occupational contacts.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document.

For undated references, the latest edition (including all amendments) applies to this document.

GBZ/T 295 General rules for occupational health biological monitoring WS/T 97 urinary creatinine spectrophotometric method WS/T 98 urinary creatinine by reversed-phase high performance liquid chromatography

3 Principle

The blood sample was diluted with a matrix modifier and measured by graphite furnace atomic absorption spectrometry at a wavelength of 357.9 nm.

4 Instruments

4.1 Volumetric flask, 10 mL, 100 mL, 500 mL, 1000 mL.

4.2 Pipettes, 50 µL,.200 µL, 1000 µL.

4.3 Balance, the sensitivity is 0.1mg.

4.4 Covered plastic centrifuge tube, 1.5 mL.

4.5 Blood collection supplies, blood collection needles, sterile cotton swabs, lithium heparin (sodium) vacuum blood collection tubes, etc.

4.6 Atomic absorption spectrometer with graphite furnace atomizer, Zeeman calibration device, chrome hollow cathode lamp.

5 Reagent

5.1 Experimental water, deionized water or quartz glass sub-boiling distilled water.

5.2 Nitric acid, high purity.

5.3 Triton X-100, chromatographically pure.

5.4 Magnesium nitrate hexahydrate, excellent grade.

5.5 Matrix modifier. Weigh 0.865 g of magnesium nitrate hexahydrate dissolved in water, add 1.0 mL Triton X-100, 2.0 mL Nitric acid, make up to 1000 mL.

5.6 Bovine blood, heparin anticoagulation, stored at -20 ° C, shake to room temperature when used. Low background blood can also be used.

5.7 Chromium standard stock solution. Accurately weigh the reference material potassium dichromate (110 °C, baking for 2 h) 1.4315 g (accurate to 0.0001 g), After dissolving with a small amount of water, transfer the whole amount to a 500 mL volumetric flask, add 5.0 mL of nitric acid, dilute to volume with water, and mix. This solution per ml Contains 1.0 mg of chromium. Or purchase a standard stock of chromium monoliths certified by the state and awarded a certificate of reference material.

5.8 Chromium standard intermediate solution [rho(Cr)=5.0 µg/mL]. The chromium monolith standard stock solution is diluted to a concentration of 5.0 with a matrix modifier.

Standard intermediate solution of µg/mL.

5.9 Chromium standard series solution. respectively absorb chromium standard intermediate solution (5.0 µg/mL) 0.0 µL, 30.0 µL, 50.0 µL, 100.0 µL, 200.0 µL, 400.0 µL, and 800.0 µL in a 10 mL volumetric flask, dilute to the mark with a matrix modifier, and mix. In each volumetric flask each liter contains 0.0 µg, 15.0 µg, 25.0 µg, 50.0 µg, 100.0 µg,.200.0 µg, and 400.0 µg of chromium. Temporary Now equipped.

6 Sample collection, transportation and storage

According to the requirements of GBZ/T 295, the venous blood of workers exposed to chromium should be collected more than 2.0 mL, shake immediately and refrigerate. Sample can be guaranteed at 4 °C it can be stored for two weeks at -20 °C for two months.

7 Analysis steps

7.1 Instrument Operation Reference Conditions

The atomic absorption spectrometer with Zeeman correction device was commissioned to the optimum condition with reference to the following instrument conditions.

a) wavelength. 357.9 nm;

b) slit. 0.7 nm;

c) Injection volume. 10 µL;

d) Graphite furnace conditions.

-- Drying. room temperature ~ 110 ° C, 20 s; 110 ° C ~ 130 ° C, 30 s;

-- Ashing. 1300 ° C, 20 s;

-- Atomization. 2300 ° C, 5 s (gas cut);

-- Clear. 2500 °C, 5 s.

7.2 Sample Pretreatment

Place the blood sample at room temperature, shake well, and aspirate 0.10 mL of the blood sample into a 1.5 mL plastic centrifuge tube. Add 0.90 mL matrix to improve.

The agent is thoroughly mixed and tested; at the same time, 0.10 mL of water is used instead of the blood sample, and the sample is treated as the reagent blank.

7.3 Preparation and determination of the working curve

Take 7 1.5 mL plastic centrifuge tubes with caps and draw 0.1 mL of 0.0µg/L~400.0 µg/L standard series solution, 0.1 mL of bovine blood, 0.8 the mL matrix modifier is mixed in a centrifuge tube and sampled according to the instrument operating reference conditions. See Table 1 for specific operations. According to the absorbance of each tube the regression equation was calculated from the difference between the standard series 1 tube absorbance and the chromium concentration (µg/L).

Table 1 blood chromium working curve standard series solution preparation

Test tube number 1 2 3 4 5 6 7 Chromium standard series solution/mL 0.10 0.10 0.10 0.10 0.10 0.10 0.10 Bovine blood/mL 0.10 0.10 0.10 0.10 0.10 0.10 0.10 Matrix improver/mL 0.80 0.80 0.80 0.80 0.80 0.80 0.80 Chromium concentration/(µg/L) Bovine blood Bottom value Bovine blood Bottom value 15 Bovine blood Bottom value 25 Bovine blood Bottom value 50 Bovine blood background Value 100 Bovine blood background Value.200 Bovine blood background Value 400

7.4 Determination

Determination of reagent blanks, sample blanks, and sample solutions using the operating conditions of the standard series of solutions, and blank and absorbance of the measured samples and samples After subtracting the reagent blank absorbance value from the degree value, the concentration of chromium (µg/L) in the sample was calculated from the regression equation.

8 Calculation

The concentration of chromium in the blood sample is calculated according to formula (1).

1cc = ...(1)

In the formula.

c -- the concentration of chromium in the blood sample, in micrograms per liter (µg/L);

C1 -- The concentration of chromium in the blood sample calculated by the regression equation in micrograms per liter (µg/L).

9 Description

9.1 The detection limit of the method is 0.47 µg/L, and the lower limit of quantification is 1.56 µg/L; the method range is 1.56 µg/L to 400.0 µg/L.

Within this range, the correlation coefficient is >0.9990; the precision within the method range is 0.6% to 6.6% (the blood chromium concentration is 4.1 µg/L to 306.1).

Gg/L, n=6); the inter-assay precision range is 1.0% to 6.7% (blood chromium concentration is 4.1 µg/L to 302.4 µg/L, n=6);

The recovery of spiked blood samples was 94.5 %~104.1% (the concentration of blood chromium was 3.2 µg/L~101.2 µg/L, and the spiked concentration was 25.0.

Gg/L ~ 300.0 µg/L, n = 6).

9.2 This method is used for blood chromium determination. The minimum sample volume of blood sample is 50.0 µL.

9.3 All the utensils used in the experiment should be soaked in nitric acid solution (1 4) overnight, rinsed repeatedly with water, and finally rinsed with deionized water.

9.4 When this method is used for the determination of blood chromium, it should not be analyzed by graphite furnace atomic absorption spectrometer with xenon lamp calibration device, otherwise it will lead to the detection limit and the lower limit of quantitation are both high.

9.5 1000.0 µg/mL of Na, K, Ca2, Mg2, Cu2, Zn2, 500.0 µg/mL of Fe3, 100.0 µg/mL of Li, Si the Ba2, Be2, Al3, Ni2, Mn2, and Pb2 ions do not interfere with the measurement.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.

How to Download GBZ/T 315-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
6 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GBZ/T 315-2018

$135.00