GBZ/T 300.128-2018Determination of toxic substances in workplace air -- Part 128: Methacrylate (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for GBZ/T 300.128-2018 in 30 minutes.

Issued by

National Health and Family Planning Commission

Level / Type

National · Recommended

Issue date

July 16, 2018

Implementation date

July 1, 2019

Scope

GBZ/T 300.128-2018 (Determination of toxic substances in workplace air -- Part 128: Methacrylate) is available as an English-translated PDF.

GBZ/T 300.128-2018 — This part of GBZ/T 300 specifies the direct injection of methyl methacrylate in the air of workplaces - gas chromatography, methacrylic Solvent desorption of acid n-butyl ester - gas chromatography and solution absorption of gas glycidyl methacrylate - gas chromatography.

This section applies to vaporous methyl methacrylate, n-butyl methacrylate and glycidyl methacrylate in workplace air. Detection of concentration.

Found what you need?

Document preview — GBZ/T 300.128-2018

National Standard of the People's Republic of China

ICS
13.100
Classification
C 60
Replacing
GBZ/T 160.64-2004

Issued by: National Health and Family Planning Commission

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Basic information on methacrylates
  • 4 Direct injection of methyl methacrylate - gas chromatography
  • 4.1 Principle
  • 4.2 Instrument
  • 4.3 Reagents
  • 4.4 Sample collection, transportation and storage
  • 4.5 Analysis steps
  • 4.6 Calculation
  • 4.7 Description
  • 5 Solvent desorption-gas chromatography of n-butyl methacrylate
  • 5.1 Principle
  • 5.2 Instruments
  • 5.3 Reagents
  • 5.4 Sample collection, transportation and storage
  • 5.5 Analysis steps
  • 5.6 Calculation
  • 5.7 Description
  • 6 Solution absorption of glycidyl methacrylate - gas chromatography
  • 6.1 Principle
  • 6.2 Instruments
  • 6.3 Reagents
  • 6.4 Sample collection, transportation and storage
  • 6.5 Analysis steps
  • 6.6 Calculation
  • 6.7 Description

Foreword

This part is the 128th part of GBZ/T 300 "Measurement of Toxic Substances in Workplace Air".

This part is drafted in accordance with the rules given in GB/T 1.1-2009.

This part replaces GBZ/T 160.64-2004 "Workplace Air Toxic Substances Determination of Unsaturated Aliphatic Esters" No. 5 the direct injection-gas chromatography of methyl methacrylate has been modified as follows.

-- modified the standard name;

- Added solvent desorption-gas chromatography of n-butyl methacrylate;

- Direct injection of methyl methacrylate - gas chromatography using a gas bag sampling, switched to a capillary column;

- Increase the basic information of the object to be tested;

-- Improved air sampling and expression of standard series concentrations;

-- Added sample blank requirements and method performance indicators.

The main drafting unit and main drafters in this section.

- Direct injection of methyl methacrylate - gas chromatography the main drafting units. Guangdong Provincial Occupational Disease Prevention and Control Institute, Zhejiang Academy of Medical Sciences, Shiyan City, Hubei Province, Occupational Disease Prevention and Treatment Institute.

Main drafters. Chen Liping, Pan Ji, Qian Yaling, Xu Bing, Zhang Geng, Yang Feng.

Solvent desorption-gas chromatography of n-butyl methacrylate Main drafting units. Jiangsu Academy of Safety Production Science, Jiangsu Provincial Center for Disease Control and Prevention.

Main drafters. Zhu Haizhen, Zhu Baoli, Han Xuelian, Cheng Wendong, Wang Xican.

--Solid absorption of glycidyl methacrylate-gas chromatography the main drafting unit. Beijing Municipal Center for Disease Control and Prevention.

Main drafters. Tao Xue, Song Jingping, Liu Yamei.

The previous versions of the standards replaced by this section are.

--GB 8776-88 Appendix A;

--GB 11520-89 Appendix A;

--GBZ/T 160.64-2004 Chapter 5.

Determination of toxic substances in workplace air Part 128. Methacrylates

1 Scope

This part of GBZ/T 300 specifies the direct injection of methyl methacrylate in the air of workplaces - gas chromatography, methacrylic Solvent desorption of acid n-butyl ester - gas chromatography and solution absorption of gas glycidyl methacrylate - gas chromatography.

This section applies to vaporous methyl methacrylate, n-butyl methacrylate and glycidyl methacrylate in workplace air.

Detection of concentration.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document.

For undated references, the latest edition (including all amendments) applies to this document.

GBZ 159 Sampling specification for monitoring of hazardous substances in the workplace air GBZ/T 210.4 Guide to the development of occupational health standards - Part 4. Methods for the determination of chemical substances in the workplace air

3 Basic information on methacrylates

The basic information of methacrylates is shown in Table 1.

Table 1 Basic information of methacrylates

Chemical material

Chemical Abstracts

(CAS number)

Molecular formula relative molecular mass Methyl methacrylate (Methyl methacrylate) 80-62-6 C5H8O2 100.12 N-butyl methacrylate (n-Butyl methacrylate) 97-88-1 CH2C(CH3)COO(CH2)3CH3 142.22 Glycidyl methacrylate (glycidyl methacrylate, Glycidyl methacrylate) 106-91-2 C7H10O3 142.15

4 Direct injection of methyl methacrylate - gas chromatography

4.1 Principle

The vaporized methyl methacrylate in the air is collected by a gas bag, directly injected, separated by a gas chromatography column, and the hydrogen flame ionization detector Detection, quantified by retention time, peak height or peak area quantified.

4.2 Instrument

4.2.1 Gas bag, the volume is 1L ~ 10L.

4.2.2 Air sampler, flow range from 0mL/min to 500mL/min, or two balls.

4.2.3 Syringe, 1 mL, 100 mL.

4.2.4 Microinjectors.

4.2.5 Gas chromatograph with hydrogen flame ionization detector. Instrument operation reference conditions.

a) Column. 30m × 0.32mm × 0.5µm, FFAP;

b) column temperature. 100 ° C;

c) gasification chamber temperature..200 ° C;

d) detection chamber temperature. 250 ° C;

e) carrier gas (nitrogen) flow rate. 1mL/min;

f) Split ratio. 10.1.

4.3 Reagents

4.3.1 Methyl methacrylate, the mass of 1 µL of liquid at 0.9 ° C is 0.936 mg.

4.3.2 Standard gas. accurately extract a certain amount of methyl methacrylate with a micro-syringe and inject it into a 100mL airtight glass syringe.

Dilute to 100.0 mL with clean air as methyl methacrylate standard gas. Or formulated with a nationally recognized standard gas.

4.4 Sample collection, transportation and storage

4.4.1 On-site sampling shall be performed in accordance with GBZ 159.

4.4.2 Short-time sampling. At the sampling point, the air sample is collected after cleaning the gas bag for 3 to 5 times with an air sample. Immediately after sampling the intake valve of the closed gas bag shall be transported and stored in a clean container. The sample shall be measured within 24 hours.

4.4.3 Sample blank. Take the gas bag to the sampling site, collect clean air, transport, save and measure with the sample. Each batch the sample is not less than 2 sample blanks.

4.5 Analysis steps

4.5.1 Sample Handling. Place the sampled gas bag in the laboratory of the measurement standard series for determination.

4.5.2 Preparation of standard curve. Take 4 to 7 100mL airtight glass syringes, and dilute the standard gas with clean air to 0.0µg/mL~ A standard series of methyl methacrylate in the concentration range of 1.50 µg/mL. Adjust the gas chromatograph to the best measurement according to the operating conditions of the instrument State, 0.50 mL was injected, and the peak height or peak area of each concentration of the standard series was determined. Measure the peak height or peak area to the corresponding methyl group the methyl acrylate concentration (µg/mL) is plotted as a standard curve or a regression equation is calculated, and the correlation coefficient should be >=0.999.

4.5.3 Sample determination. The sample gas and sample blank gas are determined by the operating conditions of the measurement standard series, and the measured peak height or peak area is determined by the standard.

The curve or regression equation gives the concentration of methyl methacrylate (µg/mL) in the sample gas. If the concentration of the analyte in the sample gas exceeds the measurement range, Determined by dilution with clean air and multiplied by the dilution factor.

4.6 Calculation

4.6.1 Calculate the concentration of methyl methacrylate in air according to formula (1).

10000 x= cC

In the formula.

C--Methyl methacrylate concentration in air, in milligrams per cubic meter (mg/m3);

C0--Measured concentration of methyl methacrylate in the sample gas (minus sample blank) in micrograms per milliliter (µg/mL).

4.6.2 The time-weighted average contact concentration (CTWA) in air is calculated in accordance with the provisions of GBZ 159.

4.7 Description

4.7.1 This method is developed in accordance with the methods and requirements of GBZ/T 210.4. The detection limit of this method is 0.001µg/mL, and the lower limit of quantification is 0.003µg/mL, the quantitative determination range is 0.003µg/mL~1.50µg/mL, the minimum detection concentration is 1mg/m3, and the lowest quantitative concentration is 3mg/m 3. The relative standard deviation is 2.3% to 8.9%.

4.7.2 This method can also be measured using equivalent other GC columns. Constant temperature measurement or temperature programmed measurement can be selected according to the measurement requirements.

4.7.3 This method can also be sampled with a 100 mL syringe.

4.7.4 The chromatographic separation of this method is shown in Figure 1. As can be seen from the figure, the methyl methacrylate peak is symmetrical and sharp, and the vinyl acetate pair is determined.

No interference.

Description.

1-vinyl acetate;

2-methyl methacrylate.

Figure 1 chromatogram

5 Solvent desorption-gas chromatography of n-butyl methacrylate

5.1 Principle

The vaporized n-butyl methacrylate in the air is collected by an activated carbon tube, and the carbon disulfide is desorbed and injected, and separated by a gas chromatography column.

Ionization detector detection, qualitative by retention time, peak height or peak area quantification.

5.2 Instruments

5.2.1 Activated carbon tube, solvent desorption type, containing 100mg/50mg activated carbon.

5.2.2 Air sampler, flow rate 0mL/min ~ 500mL/min.

5.2.3 Solvent desorption bottle, 5mL.

5.2.4 Micro syringes.

5.2.5 Gas chromatograph with hydrogen flame ionization detector. Instrument operation reference conditions.

a) Column. 30m × 0.32mm × 0.25µm, FFAP;

b) column temperature. 120 ° C;

c) gasification chamber temperature..200 ° C;

d) detection chamber temperature..200 ° C;

e) carrier gas (nitrogen) flow rate. 5mL/min;

f) Split ratio. 2.1.

5.3 Reagents

5.3.1 Carbon disulfide, chromatographic identification without interference peaks.

5.3.2 Standard solution. Add carbon disulfide to the volumetric flask. After accurate weighing, add a certain amount of n-butyl methacrylate.

Amount; add carbon disulfide to the scale, calculate the concentration of the solution from the difference between the two weighings, which is the standard stock solution. Diluted with carbon disulfide before use 500.0 µg/mL n-butyl methacrylate standard solution. Or formulated with a nationally recognized standard solution.

5.4 Sample collection, transportation and storage

5.4.1 On-site sampling shall be performed in accordance with GBZ 159.

5.4.2 Short-time sampling. At the sampling point, a 15 min air sample was collected with an activated carbon tube at a flow rate of.200 mL/min.

5.4.3 Long-time sampling. At the sampling point, an air sample of 2h to 8h is collected with an activated carbon tube at a flow rate of 50 mL/min.

5.4.4 Immediately after sampling, the ends of the activated carbon tube are closed and transported and stored in a clean container. The sample can be stored for 15 days at room temperature.

5.4.5 Sample blank. At the sampling point, open both ends of the activated carbon tube and immediately close it, then transport, store and measure with the sample.

Not less than 2 sample blanks per batch.

5.5 Analysis steps

5.5.1 Sample treatment. Pour the front and rear activated carbon into two solvent desorption bottles, add 1.0mL of carbon disulfide each, after blocking, solve Suck for 30min, shake it from time to time. The sample solution is for measurement.

5.5.2 Preparation of standard curve. Take 4 to 7 volumetric flasks and dilute the standard solution with carbon disulfide to a concentration of 0.0µg/mL to 500.0µg/mL.

The standard range of n-butyl methacrylate. Adjust the gas chromatograph to the best measurement state according to the operating conditions of the instrument, and inject the sample.

1.0 µL, respectively, to determine the peak height or peak area of each concentration of the standard series. Measure the peak height or peak area value for the corresponding butyl methacrylate the ester concentration (µg/mL) is plotted as a standard curve or a regression equation is calculated, and the correlation coefficient should be >=0.999.

5.5.3 Sample determination. The sample solution and the sample blank solution are determined by the operating conditions of the measurement standard series, and the measured peak height or peak area is determined by the standard curve or regression equation gives the concentration (µg/mL) of n-butyl methacrylate in the sample solution. If the concentration of the analyte in the sample solution exceeds the measurement range was determined by diluting with carbon disulfide, and the calculation was multiplied by the dilution factor.

5.6 Calculation

5.6.1 Convert the sample volume to the standard sample volume according to the method and requirements of GBZ 159.

5.6.2 Calculate the concentration of n-butyl methacrylate in air according to formula (2).

Vcc

21)( = ...(2)

In the formula.

C - the concentration of n-butyl methacrylate in air, in milligrams per cubic meter (mg/m3);

C1, c2-- measured concentration of n-butyl methacrylate in the sample solution before and after (minus the sample blank) in micrograms per milliliter (µg/mL);

V--the volume of the sample solution in milliliters (mL);

V0 -- standard sampling volume in liters (L);

D -- desorption efficiency, %.

5.6.3 The time-weighted average contact concentration (CTWA) in air is calculated in accordance with GBZ 159.

5.7 Description

5.7.1 This method is developed in accordance with the methods and requirements of GBZ/T 210.4. The detection limit of this method is 0.4µg/mL, and the lower limit of quantification is 1.4.

Gg/mL, the quantitative measurement range is from 1.4µg/mL to 500µg/mL; the minimum detection concentration is 0.1mg/m3, the highest detection concentration is 3L air sample.

The low quantitative concentration is 0.33 mg/m3; the relative standard deviation is 3.0% to 4.3%, and the breakthrough capacity (100 mg activated carbon) is 18.8 mg.

The rate is 99.8% to 100%, and the desorption efficiency is 94.3% to 97.6%. The desorption efficiency of each batch of activated carbon tubes should be determined.

5.7.2 methacrylic acid, acrylic acid, ethyl acrylate, methyl methacrylate and n-butyl acrylate may coexist in the air Carboxylic acids and their ester compounds do not interfere with the assay.

5.7.3 This method can also be measured using equivalent other GC columns. Constant temperature measurement or temperature programmed measurement can be selected according to the measurement requirements.

5.7.4 The chromatographic separation of this method is shown in Figure 2.

Figure 2 chromatogram

6 Solution absorption of glycidyl methacrylate - gas chromatography

6.1 Principle

The vaporized glycidyl methacrylate in the air is collected by a large bubble absorption tube containing cyclohexane, directly injected, and subjected to gas chromatography.

The column is separated and detected by a hydrogen flame ionization detector, which is characterized by retention time, peak height or peak area.

6.2 Instruments

6.2.1 Large bubble absorption tube.

6.2.2 Air sampler, flow range from 0L/min to 1L/min.

6.2.3 Curling.

6.2.4 Test tube with plug scale, 10mL.

6.2.5 Micro syringes.

6.2.6 Gas chromatograph with hydrogen flame ionization detector, instrument operation reference conditions.

a) Column. 20m × 0.2mm × 0.2µm, OV-101;

b) column temperature. 90 ° C;

c) gasification chamber temperature..200 ° C;

d) detection chamber temperature..200 ° C;

e) carrier gas (nitrogen) flow rate. 5mL/min;

f) Blowing. 60 mL/min.

6.3 Reagents

6.3.1 Cyclohexane, chromatographic identification of interference-free peaks.

6.3.2 Standard solution. Add cyclohexane to the volumetric flask. After weighing accurately, add a certain amount of glycidyl methacrylate (if necessary) Refining is required, and then accurately weighed, diluted to the mark with cyclohexane; the concentration of the solution is calculated from the difference between the two weighings, which is the standard stock solution. Temporary Previously, it was diluted with cyclohexane to a standard solution of 500.0 µg/mL glycidyl methacrylate. Or formulated with a nationally recognized standard solution.

6.4 Sample collection, transportation and storage

6.4.1 On-site sampling shall be performed in accordance with GBZ 159.

6.4.2 Short-time sampling. At the sampling point, use a large bubble absorption tube (placed in a curling pot) containing 5.0 mL of cyclohexane at 500 mL/min.

Flow collection <= 15min air sample. Immediately after sampling, the inlet and outlet of the large bubble absorption tube are closed and transported and stored in a clean container.

The sample should be measured within 24 hours.

6.4.3 Sample blank. At the sampling point, open the inlet and outlet of a large bubble absorption tube containing 5.0 mL of cyclohexane, and immediately close it, then the same product is transported, stored and measured together. Not less than 2 sample blanks per batch.

6.5 Analysis steps

6.5.1 Sample treatment. After washing the inner wall of the inlet pipe 3 times with the sample solution in the large bubble absorption tube, pour the sample solution into the stopper test.

In the tube, the absorption tube was washed with a small amount of cyclohexane, and the washing solution was incorporated into a stoppered test tube, and then diluted to 5.0 mL for measurement.

6.5.2 Preparation of standard curve. Take 4 to 7 volumetric flasks and dilute the standard solution with cyclohexane to a concentration of 0.0µg/mL to 500.0µg/mL.

A range of standard glycidyl methacrylates. Adjust the gas chromatograph to the best measurement state according to the operating conditions of the instrument.

A sample of 2.0 µL was used to measure the peak height or peak area of each concentration of the standard series. Decrease the corresponding methacrylic acid with the measured peak height or peak area the glyceride concentration (µg/mL) is plotted as a standard curve or a regression equation is calculated, and the correlation coefficient should be >=0.999.

6.5.3 Sample determination. The peak height or peak area value measured by measuring the sample solution and the sample blank solution using the operating conditions of the standard series.

The concentration (µg/mL) of glycidyl methacrylate in the sample solution was obtained from a standard curve or a regression equation. If the concentration of the analyte in the sample solution Exceeding the measurement range, it is measured by diluting with cyclohexane, and the calculation is multiplied by the dilution factor.

6.6 Calculation

6.6.1 Convert the sample volume to the standard sample volume according to the method and requirements of GBZ 159.

6.6.2 Calculate the concentration of glycidyl methacrylate in air according to formula (3).

In the formula.

C--the concentration of glycidyl methacrylate in air, in milligrams per cubic meter (mg/m3);

C0--measurement of the concentration of glycidyl methacrylate in the sample solution (minus the sample blank) in micrograms per milliliter (µg/mL);

V--the volume of the sample solution in milliliters (mL);

V0 - the standard sampling volume in liters (L).

6.7 Description

6.7.1 This method is developed in accordance with the methods and requirements of GBZ/T 210.4. The detection limit of this method is 1.6µg/mL, and the lower limit of quantification is 5.3.

Gg/mL, the quantitative determination range is 5.3µg/mL~500µg/mL; the minimum detection concentration is 1mg/m3, the highest detection concentration is 7.5L air sample.

The low quantitative concentration was 3.5 mg/m3.

6.7.2 Cyclohexane is volatile, the sampling flow rate cannot be large, and the sampling time cannot be long.

6.7.3 This method can also be measured using equivalent other GC columns. Constant temperature measurement or temperature programmed measurement can be selected according to the measurement requirements.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

How to Download GBZ/T 300.128-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GBZ/T 300.128-2018

$95.00