Valid

GB/Z 42520-2023Guidelines for X-ray fluorescence spectrometric laboratory practice for the analysis of iron ores (English PDF)

Also coversGBZ42520-2023

Open the GB/Z 42520-2023 preview as PDF

Preview — first pages of GB/Z 42520-2023

This is a limited preview

Buy now to download the full PDF

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

May 23, 2023

Implementation date

December 1, 2023

Scope

GB/Z 42520-2023 (Guidelines for X-ray fluorescence spectrometric laboratory practice for the analysis of iron ores) is available as an English-translated PDF.

GB/Z 42520-2023 — This document provides the operation guide for the iron ore X-ray fluorescence spectroscopic analysis laboratory (hereinafter referred to as "laboratory"): This document is suitable for quality control in laboratories:

Document preview — GB/Z 42520-2023

National Standard of the People's Republic of China

ICS
73.060.10
Classification
D 31

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • foreword
  • 2016 Chapter 3, paragraph 1):
  • 1 Scope
  • 2 Normative references

foreword

This document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules for Standardization Documents"

drafting:

This document is modified to adopt ISO /T R18336:2016 "Guidelines for Good X-ray Fluorescence Laboratory Practice in the Iron Ore Industry":

Compared with ISO /T R18336:2016, this document has more adjustments in structure: Struct number changes between two files compared to one

See Appendix A for a list:

The technical differences between this document and ISO /T R18336:2016 and their reasons are as follows:

--- Added the definitions of "counting statistical error", "reading error" and "melt sheet preparation error" (see 3:1, 3:2 and 3:3) to facilitate this document

correct understanding of the application;

--- Added GB/T 6379:1 and GB/T 6379:2 for normative references, and changed the calculation requirements of precision from "should be in accordance with the appendix

G stipulated" was changed to "should be carried out in accordance with GB /Z 42358-2023, GB/T 6379:1 and GB/T 6379:2" (see

6:3), in order to meet the actual application;

---Change the role of Appendix F and Appendix H from normative to informative, so as to comply with the provisions of GB/T 1:1-2020;

---Replace ISO /T R18231 with normatively quoted GB /Z 42358-2023 (see Table 1, 7:1) to adapt to my country's technical regulations

pieces to increase operability;

---Replace ISO 3082 (see 7:2) with the normatively quoted GB/T 10322:1-2014 to adapt to my country's technical conditions, adding

Operability;

---Replace ISO 7870-2 (see 7:3) with the normatively quoted GB/T 17989:2-2020 to adapt to my country's technical conditions, adding

Increase operability:

The following editorial changes have been made to this document:

---Change the name of the standard to "Operation Guidelines for Iron Ore X-ray Fluorescence Spectroscopic Analysis Laboratory";

--- Deleted the expression "Because this document is a guiding technical report, not a national mandatory standard" (see ISO /T R18336:

2016 Chapter 3, paragraph 1):

Please note that some contents of this document may refer to patents: The issuing agency of this document assumes no responsibility for identifying patents:

1 Scope

This document provides the operation guide for the iron ore X-ray fluorescence spectroscopic analysis laboratory (hereinafter referred to as "laboratory"):

This document is suitable for quality control in laboratories:

2 Normative references

The contents of the following documents constitute the essential provisions of this document through normative references in the text: Among them, dated references

For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to

this document:

GB/T 6379:1 Accuracy of measurement methods and results (trueness and precision) Part 1: General principles and definitions

GB/T 6379:2 Accuracy of measurement methods and results (trueness and precision) Part 2: Determining the weight of standard measurement methods

Basic methods for reproducibility and reproducibility

GB/T 10322:1-2014 iron ore sampling and sample preparation method (ISO 3082:2009, IDT)

GB/T 17989:2-2020 Control Drawings Part 2: Conventional Control Drawings (ISO 7870-2:2013, MOD)

GB /Z 42358-2023 Determination of accuracy of wavelength dispersive X-ray fluorescence spectrometer for iron ore (ISO /T R18231:

2016, MOD)

ISO 9516-1:2003 Determination of multi-element content of iron ores - Wavelength dispersive X-ray fluorescence spectrometry - Part 1: Comprehensive process

prehensive procedure)

encematerials (CRMs)]

The following terms and definitions apply to this document:

3:1

Under certain measurement conditions (voltage, current, optical filter, limiting diaphragm, attenuator, collimator, spectroscopic crystal, pulse height analyzer

(PHA, 2theta, detector, measurement time, etc:), the error caused by the X-ray fluorescence spectrometer detector counting statistics process:

3:2

Reading error readingerror

Errors caused during the operation of X-ray fluorescence spectrometer instruments and components:

Note: Including detector X-ray counting leakage meter, X-ray light source fluctuation, circuit fluctuation, spectroscopic crystal fluctuation, instrument fluctuation, etc:

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 6379 · GB/T 10322 · ISO 3082 · GB/T 17989 · ISO 7870 · ISO 9516

How to Buy GB/Z 42520-2023

  1. 1Add to cart. Click the "Buy GB/Z 42520-2023" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/Z 42520-2023

$365.00

$310.00for partners