GB/Z 36281-2018Residual current devices (RCDs) associated with additional function (s) (English PDF)
Also coversGBZ36281-2018
Open the GB/Z 36281-2018 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
June 7, 2018
Implementation date
January 1, 2019
Scope
GB/Z 36281-2018 (Residual current devices (RCDs) associated with additional function (s)) is available as an English-translated PDF.
GB/Z 36281-2018 — This guidance document gives the following information that may be used. --- Dedicated additional features declared by the manufacturer to be assembled with residual current protection appliances (RCDs) that meet household and similar use standards; --- A specific RCD with built-in additional features that meets household and similar usage standards. Note 1. The term RCD is a generic term that applies to a family of products that automatically break when the residual current equals or exceeds its rated residual operating current, Ideltan. This general term is usually applied to the following appliances. ---RCCB residual current operated circuit breaker without overcurrent protection; ---RCBO residual current operated circuit breaker with overcurrent protection; ---SRCD socket type residual current appliances with or without overcurrent protection; ---PRCD Mobile residual current device without overcurrent protection. This guidance document identifies the applicable test procedures for determining the effects of a particular RCD on a normal function, and the specific RCD declared is appropriate. Built in or assembled with one or more additional features. This guidance document can also be used to draft additional requirements for additional functional standards that are expected to be combined with home and similar use RCDs. This guidance document provides an evaluation-based procedure to clarify the necessary tests to meet the appropriate requirements. If built in There is no additional test according to this guidance document, as the additional functions in the RCD are evaluated without damaging the RCD. Multiple additional features can be combined with one or more RCDs to check for the most severe combinations. This guidance document does not apply to the following situations. --- Existing standards clearly specify additional features in combination with home and similar use RCDs; Note 2. An example of an additional function appliance with a separate product standard is an auxiliary contact assembly in accordance with GB/T 20640. ---Additional functions combined with RCD for connection purposes; Note 3. An example of an additional function for achieving the connection purpose is the connection between the RCCB and the CB. ---Locking device.
Document preview — GB/Z 36281-2018
National Standard of the People's Republic of China
- ICS
- 29.200
- Classification
- K 31
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
Foreword
This guidance technical document was drafted in accordance with the rules given in GB/T 1.1-2009.
This guidance document uses the redrafting method to modify the residual current protection using IEC /T R62710.2015 with additional functional combinations.
Protective appliances.
The technical differences and reasons for this guidance document and IEC /T R62710.2015 are as follows.
--- Regarding the normative reference documents, this guidance technical document has been technically adjusted to adapt to the technical regulations of our country.
The adjustments are concentrated in Chapter 2, "Regulatory References", and the specific adjustments are as follows.
* Replace IEC /CISPR14-1 with GB 4343.1 equivalent to the international standard;
* Replace IEC /T R60755 with GB/T 6829 modified to adopt international standards;
* Replace IEC 60898 (all parts) with GB/T 10963 (all parts) equivalent to international standards;
* Replace IEC 60479 (all parts) with GB/T 13870 (all parts) equivalent to international standards;
* Replace IEC 60364 (all parts) with GB/T 16895 (all parts) equivalent to international standards;
* Replace IEC 61008 (all parts) with GB/T 16916.1-2014 modified to international standards;
* Replace IEC 61009 (all parts) with GB/T 16917.1-2014 modified to international standards;
* Replace IEC 61543.1995 with GB/T 18499-2008 equivalent to the international standard;
* Replace IEC 61540 with GB/T 20044 modified to adopt international standards;
* Replace IEC 62423 with GB/T 22794 equivalent to the international standard;
* Replace IEC 62640 with GB/T 28527 modified to adopt international standards;
* Replace IEC 62335 with GB/T 29303 modified to international standards.
--- "The connection between RCBO and CB" in Note 3 of Chapter 1 is changed to "the connection between RCCB and CB";
--- 9.4 title "4.3 classification" was changed to "4.2b) classification";
---Modified the contents of Table 1.
* In the header, "Example. Test f according to IEC 61009-1.2010" is modified to "Example according to GB/T 16917.1-2014
(IEC 61009-1.2012, MOD) test f", clause number and test items are changed accordingly;
* "10.3" in test procedure D1 was changed to "9.5.4 of this guidance technical document";
* In test procedure I, the "radiation high frequency phenomenon" is modified to "radiation electromagnetic field";
* In test procedure J, the two test contents were modified to. "Common mode conducted disturbance in the frequency range below 150 kHz" and "static
Discharge".
The following editorial technical documents have been edited as follows.
--- According to the requirements of GB/T 1.1-2009, according to the normative reference in the text, IEC /T R62710.2015 reference
IEC 61540, IEC 61543, IEC 62335, IEC 62640, IEC 60364, IEC 60479 and IEC /CISPR
14-1 is adjusted to a normative reference (see Chapter 2).
This guidance technical document was proposed by the China Electrical Equipment Industry Association.
This guidance technical document is under the jurisdiction of the National Low Voltage Apparatus Standardization Technical Committee (SAC/TC189).
This guiding technical document drafting unit. Shanghai Electric Apparatus Research Institute, Hangzhou Ganlong Electric Co., Ltd., Shanghai Liangxin Electric Co., Ltd.
Company, Xiamen Hongfa Switchgear Co., Ltd., Zhejiang Zhengtai Electric Co., Ltd., Shanghai Dianke Electric Technology Co., Ltd., Shanghai Nuo
Jacques Electric Co., Ltd., Wuxi Xinhongtai Electrical Technology Co., Ltd., Suzhou Future Electric Co., Ltd., Shanghai Siemens Line
Protection Systems Co., Ltd., Schneider Electric (China) Co., Ltd. Shanghai Branch, Zhongshan Kaipu Electric Co., Ltd., Beijing ABB Low Voltage
Electric Appliance Co., Ltd., Shanghai Electric Co., Ltd. People's Electric Appliance Factory, Zhejiang Tianzheng Electric Co., Ltd., Changan Group Co., Ltd., Shenzhen
Shenzhen Lianghui Technology Co., Ltd., Yuyao Jiarong Electronic Appliance Co., Ltd., Ningbo Bull Electric Co., Ltd., Hongxiu Electric Co., Ltd., US
Gao Electric Technology Co., Ltd.
Introduction
This guidance document presents information that allows manufacturers to combine additional functions with residual current protection appliances. To this end, this guide
Sex technical documents introduce requirements and trials. This guidance document will also assist in the RCD of laboratory testing combined with additional features.
This guidance document does not include the additional functionality itself (as defined by the additional functional standards), nor does it include the functionality and features of the RCD (by RCD)
standard regulation). In the absence of additional functional standards for home and similar purposes, this guidance document is limited to checking for additional features.
Any function that damages the RCD. In the case of additional functional standards related to household and similar uses, the relevant standards apply. This means
The combination of RCD and additional functions works as described above.
This guidance document is drafted in accordance with the following basic principles.
--- In order not to limit innovation, this guidance technical document is not related to additional features, and this guidance technical document applies to any additional
Features;
Note. It is not possible to list all of the additional features that may be present and future, and several examples are given in the definition.
--- Verification is limited to a combination of one RCD and one or more additional functions (integral or non-integral);
---The purpose of verification is to prove that one or more additional features (declared to match a particular protective device) and RCD combination is
All, and the combination does not impair the basic characteristics of the RCD;
--- requires additional features and assembly of the RCD is limited to the same manufacturer or the same trademark. Therefore, the manufacturer or trademark holds
It should be stated what additional features the protective device can be assembled with.
Residual current protection device combined with additional functions
1 Scope
This guidance document gives the following information that may be used.
--- Dedicated additional features declared by the manufacturer to be assembled with residual current protection appliances (RCDs) that meet household and similar use standards;
--- A specific RCD with built-in additional features that meets household and similar usage standards.
Note 1. The term RCD is a generic term that applies to a family of products that automatically break when the residual current equals or exceeds its rated residual operating current, Ideltan.
This general term is usually applied to the following appliances.
---RCCB residual current operated circuit breaker without overcurrent protection;
---RCBO residual current operated circuit breaker with overcurrent protection;
---SRCD socket type residual current appliances with or without overcurrent protection;
---PRCD Mobile residual current device without overcurrent protection.
This guidance document identifies the applicable test procedures for determining the effects of a particular RCD on a normal function, and the specific RCD declared is appropriate.
Built in or assembled with one or more additional features.
This guidance document can also be used to draft additional requirements for additional functional standards that are expected to be combined with home and similar use RCDs.
This guidance document provides an evaluation-based procedure to clarify the necessary tests to meet the appropriate requirements. If built in
There is no additional test according to this guidance document, as the additional functions in the RCD are evaluated without damaging the RCD.
Multiple additional features can be combined with one or more RCDs to check for the most severe combinations.
This guidance document does not apply to the following situations.
--- Existing standards clearly specify additional features in combination with home and similar use RCDs;
Note 2. An example of an additional function appliance with a separate product standard is an auxiliary contact assembly in accordance with GB/T 20640.
---Additional functions combined with RCD for connection purposes;
Note 3. An example of an additional function for achieving the connection purpose is the connection between the RCCB and the CB.
---Locking device.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB 4343.1 Electromagnetic compatibility requirements for household appliances, power tools and similar appliances - Part 1 . Launching (GB 4343.1-2009,
CISPR14-1..2005, IDT)
GB/T 6829 General requirements for residual current operated protective devices (RCD) (GB/T 6829-2017, IEC /T R60755.
2008, MOD)
GB/T 10963 (all parts) Electrical accessories overcurrent protection circuit breakers for household and similar places [IEC 60898 (all parts)
Minute)]
GB/T 13870 (all parts) Effect of current on humans and livestock [IEC 60479 (all parts)]
GB/T 16895 (all parts) Low-voltage electrical installations [IEC 60364 (all parts)]
GB/T 16916.1-2014 Residual current operated circuit breakers (RCCB) without overcurrent protection for household and similar purposes 1
Part. General Rules [IEC 61008-1.2012, MOD]
GB/T 16917.1-2014 Residual current operated circuit breakers (RCBO) with overcurrent protection for household and similar purposes Part 1
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
- GB 4343.1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
- GB 4343.1-2009Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
GB/T 6829 · GB/T 6829-2017 · GB/T 10963 · IEC 60898 · GB/T 13870 · IEC 60479 · GB/T 16895 · IEC 60364 · GB/T 16916.1-2014 · IEC 61008 · GB/T 16917.1-2014
How to Buy GB/Z 36281-2018
- 1Add to cart. Click the "Buy GB/Z 36281-2018" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 4343.1-2024 — Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
GB/T 10963.1-2020 — Electrical accessories. Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a. c. operation
GB/T 10963.2-2020 — Electrical accessories. Circuit-breakers for overcurrent protection for household and similar installations - Part 2: Circuit-breakers for AC and DC operation
Secure payment via Stripe
Payments accepted
GB/Z 36281-2018
$360.00