GB/Z 28820.1-2012Long-term radiation ageing in polymers -- Part 1: Techniques for monitoring diffusion-limited oxidation (English PDF)
Also coversGBZ28820.1-2012
Open the GB/Z 28820.1-2012 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
Ministry of Health of the People's Republic of China
Level / Type
National · Recommended
Issue date
November 5, 2012
Implementation date
February 1, 2013
Scope
GB/Z 28820.1-2012 (Long-term radiation ageing in polymers -- Part 1: Techniques for monitoring diffusion-limited oxidation) is available as an English-translated PDF.
GB/Z 28820.1-2012 — When oxygen is present, the polymer ages in a variety of environments, including temperature, radiation, or ultraviolet light, and is affected by diffusion-limited oxidation. Non-homogeneous aging caused by. These effects make it difficult to understand the aging process and to infer accelerated long-term exposure conditions. This section reviews quantitative The experimental techniques for monitoring these effects provide theoretical equations for assessing the importance.
Document preview — GB/Z 28820.1-2012
National Standard of the People's Republic of China
- ICS
- 29.035.01
- Classification
- K 15
Issued by: Ministry of Health of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 to monitor diffusion-limited oxidation profiling techniques
- 2.1 infrared analysis technology
Foreword
GB /Z 28820 "polymer long-term radiation aging" consists of three parts.
--- Part 1. Monitoring of diffusion-limited oxidation technology;
--- Part 2. Prediction of aging programs at low dose rates;
--- Part 3. Low voltage cable materials in service monitoring procedures.
This section GB /Z 28820 Part 1.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method is equivalent to using IEC /T S61244-1.1993 "polymer long-term radiation aging Part 1. Monitoring diffusion limit
Oxidation technology. "
This part is proposed by China Electrical Equipment Industry Association.
This part of the National Electrical Insulation Materials and Insulation Evaluation Committee Standardization Technical Committee (SAC/TC301) centralized.
This part of the drafting unit. Shenzhen Asahi Health Sanyi Science and Technology Co., Ltd., Beijing Institute of Electrical Technology Machinery Industry, Shanghai Cable Research
Institute, Shanghai Nuclear Industry Research and Design Institute, Shanghai Special Cable Electrical Technology Co., Ltd., Jiangsu Shangshang Cable Group Co., Ltd., Shanghai Cable Factory
Co., Ltd., Linhai Yadong Special Cable Material Factory, Shanghai Kaibo Special Cable Material Factory Co., Ltd., Wuxi Jiangnan Cable Co., Ltd., Changzhou Ba Yi
Cable Co., Ltd., Shanghai Zhidaohua Polymer Materials Co., Ltd., Shanghai Innovation High Temperature Cable Factory, Zhejiang Wanma Cable Co., Ltd.
Company, Shenzhen Walnut Nuclear Materials Co., Ltd., Beijing North Heavy Turbine Electric Co., Ltd., Beijing Xin Rui Runda Insulation Limited
Responsible company.
Introduction
It is often necessary to assess the expected lifetime of a polymeric material in a variety of different applications. In order to extend the service life,
Commonly used accelerated aging technology to predict the service life, this technology is to use higher than the ambient conditions to get the result. In a variety of realities
Applications, there are direct exposure to air conditions, which shows that oxidation is an important reason for material degradation. Unfortunately, aggregation
Exposure to air during aging often leads to non-uniform oxidation example results. Therefore, it is necessary to try a method that is both understandable
Oxidation process in turn can infer the impact of long-term exposure to accelerated aging.
The complexity of heterogeneous oxidation is paramount, with diffusion limited oxidation included. In a variety of environments, this complex and meaningful
Methods include many years of recognized heat [1] [2-4] and ultraviolet radiation [5]. When a material oxygen consumption rate greater than the ambient by the proliferation of make up
When oxygen is supplied to the interior of the material, diffusion-limited oxidation can occur. This example results in the concentration of oxygen equilibrating the adsorption value from the sample surface
Smoothly drops to the lower or non-existent value inside the sample. This will cause heterogeneous oxidation of the material, and oxygen generation on the surface of the material
(Eg, equivalent to an air-saturated environment) so as to reduce or not cause internal oxidation.
The geometry of the material is important, plus the rate of oxygen consumption, the oxygen permeability coefficient, and the partial pressure of oxygen in the surrounding sample [5-8]
ring. Because the rate of oxygen consumption generally depends on the ambient pressure level (eg, temperature, radiation dose rate), and when the material degrades [9-10], oxygen
The rate of consumption and the oxygen permeability coefficient will also vary, and the importance of diffusion-limited oxidation will vary with pressure levels and degradation. This
It is shown that the percentage of samples oxidized under high pressure is substantially lower than the percentage oxidized under low pressure conditions [5-7,10-16].
Therefore, in order to determine conclusively whether short-term acceleration can simulate long-term air aging conditions, the key is to monitor and quantitatively understand the diffusion limit
The impact of oxidation.
Recently, a large number of improvement studies in this field have demonstrated that diffusion-limited oxidation can be achieved. This section reviews
this field. Chapter 2 describes an experimental profiling method that can be used to monitor diffusion-limited oxidation. Chapter 3 will briefly introduce this
As the theoretical description. The shape of the theoretical graph depends on the oxygen permeability coefficient and oxygen consumption rate, and these quantities must be measured or estimated to
From the data to verify the validity of the theory. Many experimental methods have been developed to measure the permeability coefficient, and a large amount of data can be found in the literature
To Chapter 4 will introduce some important documents. The experimental method of estimating oxygen consumption rate is briefly reviewed in Chapter 5. Experimental data support
Theory of treatment is introduced in Chapter 6. Once the trusted theoretical treatment exists, this theory can be used to select experimental aging bars
Or predict the importance of such effects, the impact of proliferation is not significant. If it is impossible to eliminate the proliferation of shadow in the air aging conditions
Ringing increases the oxygen pressure on the surrounding sample at the time of aging, which in some instances is used to obtain the desired result, as outlined in Chapter 7 for oxygen
Overvoltage technology.
Part 2 of GB /Z 28820 will be published separately and describe the procedure for predicting radiation aging at low dose rates.
Long-term polymer radiation aging
Part 1. Techniques for monitoring diffusion limiting oxidation
1 Scope
When oxygen is present, the polymer ages in a variety of environments, including temperature, radiation, or ultraviolet light, and is affected by diffusion-limited oxidation.
Non-homogeneous aging caused by. These effects make it difficult to understand the aging process and to infer accelerated long-term exposure conditions. This section reviews quantitative
The experimental techniques for monitoring these effects provide theoretical equations for assessing the importance.
2 to monitor diffusion-limited oxidation profiling techniques
Diffusion Limits The presence of oxidative effects indicates that various properties are associated with certain oxidations depending on the material
In the space location. Therefore, any technique that can be mapped into a spatial map can be used to monitor diffusion-limited oxidation. Because of the few polymers
The structure is expressed in cross-sections down to a few millimeters or less, and diffusion-limiting oxidation effects work on small dimensions. Therefore, cut
Analysis techniques should have a resolution of 100 µm. Another sensitivity-related issue is measured data, which degrades the polymer in general
It is true that less than 1% of the polymer is oxidized. Therefore, a useful analytical techniques should have the condition is that with reasonable results,
Sensitive to minute chemical changes, research can be applied extensively, and operation and analysis are relatively straightforward. This chapter briefly describes some special ones
Technology used.
2.1 infrared analysis technology
The impact of infrared spectroscopy to monitor diffusion-limited oxidation has been exceeded due to the ability of sheet samples to provide detailed chemical information
25 years [17]. Whether it is the effect of sample thickness or the effect of ultrathin sections, any oxidation-sensitive infrared peak can be monitored, allowing
To get heterogeneous oxidation information. Many research data show that the absorption peak of carbonyl group in polyolefin material is about 1720cm-1,
Such as polyethylene and polypropylene, characterize the infrared absorption peaks of this region with higher sensitivity, and these materials do not have absorption peaks when not aged.
Since the carbonyl region represents the superposition of the absorption peaks of various oxidation products (such as ketones, aldehydes, esters and acids) and has different elimination at different wavelengths
The light coefficient, therefore, simplifies assumptions to extract semi-quantitative information. In most cases, you can choose the maximum height or location of multiple carbonyl peaks
area. It is important to note that materials on the market contain additives (such as antioxidants, flame retardants) that often have absorption peaks in the carbonyl region and therefore
FTIR spectroscopy has complicated the testing of these materials. Figure 1 shows an infrared image of a material that has been ultrasonically sliced after aging
Anatomy of the sample diagram [18]. Polyolefin materials were placed in air and aged at 100 ° C for 6 days to characterize the relative degree of oxidation
Light) on the surface of the sample from the air. There is an approximate exponential level of correlation between the degree of oxidation and air exposure, heat aging materials
A similar pattern can be observed [10,13,14].
The second infrared treatment is the use of packaging film to obtain multilayer samples under mechanical pressure. After aging, the films are separated and carried separately
analysis. Unsteady low-density polyethylene material in the air after gamma-ray aging, carbonyl carbonyl obtained in this way profile is shown in Figure 2
Show [19]. This profile is symmetrical because both surfaces of the multilayer sample are exposed to the air. Profiles of these samples are completely oxygenated
There was a sudden shift in the area of oxidation and non-oxidation, which was observed on the power function plot in Figure 1.
Another notable improvement is the use of microscopic Fourier transform infrared spectroscopy (FTIR) as the analytical method. Jouan and others
[20,21] pioneered this method and analyzed the carbonyl absorption peak of the PVC material by photooxidation [20] and also plotted styrene-butadiene
Diene (SBR) rubber and nitrile rubber [21]. Figure 3 shows the photo-oxidation of SBR membrane in air for 100h [21]. This
In this case, the oxidation is significantly reduced when away from the air, which is very similar to the result shown in Fig. 1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
How to Buy GB/Z 28820.1-2012
- 1Add to cart. Click the "Buy GB/Z 28820.1-2012" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/Z 28820.3-2012 — Long-term radiation ageing in polymers -- Part 3: Procedures for in-service monitoring of low-voltage cable materials
GB/Z 120.305-2026 — Microgrids - Part 3-5: Testing for microgrid monitoring, control, and energy management systems
GB/Z 121-2026 — Evaluation index system for sustainable rural development
Secure payment via Stripe
Payments accepted
GB/Z 28820.1-2012
$410.00