GB/Z 18039.1-2019Electromagnetic compatibility - Environment - Description and classification of electromagnetic environments (English PDF)
This is a limited preview
Buy now to download the full PDF (204 pages)
Need quotation for your management?
Get a formal quotation for GB/Z 18039.1-2019 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
June 4, 2019
Implementation date
January 1, 2020
Scope
GB/Z 18039.1-2019 (Electromagnetic compatibility - Environment - Description and classification of electromagnetic environments) is available as an English-translated PDF.
GB/Z 18039.1-2019 — Understanding the electromagnetic environment in electrical, electronic, and system workplaces is an important prerequisite for achieving electromagnetic compatibility.
Can be used in a variety of ways This is understood, including on-site surveys of scheduled locations, technical assessments of equipment and systems, and general information.
This part. --- introduced the concept of harassment and defined the degree of disturbance of each electromagnetic phenomenon; ---Classify various types of places and describe their attributes; --- Provides background information on the different electromagnetic phenomena that may exist in the environment;...
Found what you need?
Document preview — GB/Z 18039.1-2019
National Standard of the People's Republic of China
- ICS
- 33.100.20
- Classification
- L 06
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- 1 Scope
Foreword
The Electromagnetic Compatibility Environment includes the following sections.
---GB /Z 18039.2-2000 Electromagnetic compatibility environment industrial equipment power supply low frequency conducted disturbance emission level evaluation
---GB/T 18039.3-2017 Electromagnetic compatibility environment common low-voltage power supply system low-frequency conduction disturbance and signal transmission
Capacity level
---GB/T 18039.4-2017 Compatibility level of low frequency conducted disturbance in electromagnetic compatibility environment factory
---GB /Z 18039.5-2003 Electromagnetic compatibility environment public power supply system low frequency conduction disturbance and electromagnetic transmission of signal transmission
surroundings
---GB /Z 18039.6-2005 Electromagnetic compatibility environment Low frequency magnetic field in various environments
---GB /Z 18039.7-2011 Electromagnetic compatibility environment, voltage sag, short-term interruption and its measurement system
Result
---GB/T 18039.8-2012 Electromagnetic compatibility environment High altitude nuclear electromagnetic pulse (HEMP) environment describes conducted disturbance
---GB/T 18039.9-2013 Electromagnetic compatibility environment common medium voltage power supply system low frequency conduction disturbance and signal transmission
Capacity level
---GB/T 18039.10-2018 Electromagnetic compatibility environment HEMP environment describes radiated disturbance
This part is the first part of the Electromagnetic Compatibility Environment.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part replaces GB /Z 18039.1-2000 "Classification of electromagnetic environment for electromagnetic compatibility environment", and GB /Z 18039.1-2000
In comparison, the main technical changes are as follows.
--- Refined the scope and content of Chapter 1;
--- Chapter 2 added normative references;
--- Chapter 3 adds 34 terms and definitions, and 118 abbreviations;
--- Added the definition of device port in 4.1, and the content of 4.4 disturbance level and CISPR limit;
--- Revised the 5.1.1 fundamental harmonics, 5.1.2 grid voltage amplitude and frequency changes, 5.1.6 low frequency induced voltage requirements, and
5.2.1 description of the magnetic field, 5.2.2 electric field;
--- Increase the content of 5.1.3 grid common mode voltage, 5.1.4 grid signal voltage, 5.1.7 AC grid DC voltage;
--- Revised the description of 6.1.1, the description of the 6.1.4 transient, and the requirements of 6.1.3 induced continuous wave, 6.2.2 continuous oscillation radiation disturbance;
--- Added 6.1.2 direct conduction continuous wave phenomenon, 6.2.1 overview, 6.2.3 modulated radiation disturbance, 6.2.4 pulse radiation disturbance
content;
--- Revised the requirements of the field generated by the 7.3 electrostatic discharge current;
--- Added the content of Chapter 8 environment type;
--- Increased the content of 9.3 high-density source processing, modified the description of the 9.4 critical state criterion;
--- Added the content of the harassment level of different types of places in Chapter 10;
--- Increased the compatibility level/harassment level of different types of sites in Appendix A, Appendix C Overview of historical distribution of radiation disturbances, Appendix E
Harness and compatibility levels in Powerline Communications (PLT), Appendix F Distributed Generation, and Appendix GIEC 61000-2 Series
The content of the information;
--- Revised Appendix B for requirements for continuous radiated disturbances, and Appendix D for description of pulsed radiated disturbances.
This section uses the translation method equivalent to IEC /T R61000-2-5.2017 "Electromagnetic Compatibility (EMC) Part 2-5. Environmental Electromagnetics
Description and Classification of the Environment.
The documents of our country that have a consistent correspondence with the international documents referenced in this part are as follows.
---GB/T 17626.2-2018 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test (IEC 61000-4-2.
2008, IDT)
---GB/T 17626.3-2016 Electromagnetic compatibility test and measurement technology RF electromagnetic field radiation immunity test (IEC
61000-4-3.2010, IDT)
---GB/T 17626.4-2018 Electromagnetic compatibility test and measurement technology Electrical fast transient burst immunity test (IEC
61000-4-4.2012, IDT)
---GB/T 17626.5-2008 Electromagnetic compatibility test and measurement technology Surge (impact) immunity test (IEC 61000-4-
5.2005, IDT)
---GB/T 17626.6-2017 Electromagnetic compatibility test and measurement technology Conducted disturbance immunity of radio frequency field induction (IEC
61000-4-6.2013, IDT)
---GB/T 17626.8-2006 Electromagnetic compatibility test and measurement technology Power frequency magnetic field immunity test (IEC 61000-4-8.
2001, IDT)
---GB/T 17626.9-2011 Electromagnetic compatibility test and measurement technology Pulse magnetic field immunity test (IEC 61000-4-9.
2001, IDT)
---GB/T 17626.10-2017 Electromagnetic compatibility test and measurement technology Damping oscillating magnetic field immunity test (IEC 61000-
4-10.2001, IDT)
---GB/T 17626.11-2008 Electromagnetic compatibility test and measurement technology resistance to voltage dips, short interruptions and voltage changes
Disturbance test (IEC 61000-4-11.2004, IDT)
---GB/T 17626.12-2013 Electromagnetic compatibility test and measurement technology ringing wave immunity test (IEC 61000-4-12.
2006, IDT)
---GB/T 17626.13-2006 Electromagnetic compatibility test and measurement technology AC power port harmonics, interharmonics and grid letters
Low frequency immunity test (IEC 61000-4-13.2002, IDT)
---GB/T 17626.14-2005 Electromagnetic compatibility test and measurement technology voltage fluctuation immunity test (IEC 61000-4-
14.2002, IDT)
---GB/T 17626.16-2007 Electromagnetic compatibility test and measurement technology 0Hz~150kHz common mode conducted disturbance immunity
Test (IEC 61000-4-16.2002, IDT)
---GB/T 17626.18-2016 Electromagnetic compatibility test and measurement technology Damping oscillator wave immunity test (IEC 61000-4-
18.2011, IDT)
---GB/T 17626.27-2006 Electromagnetic compatibility test and measurement technology three-phase voltage unbalance immunity test (IEC
61000-4-27.2000, IDT)
---GB/T 17626.28-2006 Electromagnetic compatibility test and measurement technology power frequency change immunity test (IEC 61000-
4-28.2001, IDT)
---GB/T 18039.3-2017 Electromagnetic compatibility environment common low-voltage power supply system low-frequency conduction disturbance and signal transmission
Capacity level (IEC 61000-2-2.2002, IDT)
---GB/T 18039.4-2017 Compatible level of low frequency conducted disturbance in electromagnetic compatibility environment factory (IEC 61000-2-4.
2002, IDT)
---GB /Z 18039.7-2011 Electromagnetic compatibility environment, voltage sag, short-term interruption and its measurement system
Results (IEC TR61000-2-8.2002, IDT)
---GB/T 18039.9-2013 Electromagnetic compatibility environment common medium voltage power supply system low frequency conduction disturbance and signal transmission
Capacity level (IEC 61000-2-12.2003, IDT)
---GB/T 18039.10-2018 Electromagnetic compatibility environment HEMP environment describes radiated disturbance (IEC 61000-2-9.
1996, IDT)
This section has made the following editorial changes.
--- In order to adapt to China's standard system, the standard name was changed to "Description and Classification of Electromagnetic Environment for Electromagnetic Compatibility Environment";
--- Added abbreviations and descriptive text for ease of understanding and use.
* Add "HF (high frequency)" abbreviations in 3.2, in line with GB/T 1.1-2009 requirements;
* 5.2.1 Table 9 footnote f and 5.2.2 Table 10 footnote a, added a sentence "China's railway traction system uses 50Hz"
Descriptive text;
* In 9.4, after "Performance Criterion DS", add "(Defined Status)" for explanation.
This part is proposed and managed by the National Electromagnetic Compatibility Standardization Technical Committee (SAC/TC246).
This section was drafted by. China Electric Power Research Institute Co., Ltd., Ministry of Industry and Information Technology, Fifth Institute of Electronics, State Grid Limited
Company, China Household Electric Appliance Research Institute, Beijing Radio Measurement and Testing Institute, Chongqing Institute of Information and Communication, Hubei Province Medical Device Quality Supervision
Inspection and Research Institute, China Southern Power Grid Science Research Institute Co., Ltd., Shanghai Sanji Electronic Industry Co., Ltd., Zhuhai City, Guangdong Province
Volume Supervision and Inspection Institute, Guangdong Product Quality Supervision and Inspection Institute, Yunnan Power Grid Co., Ltd.
1 Scope
Understanding the electromagnetic environment in electrical, electronic, and system workplaces is an important prerequisite for achieving electromagnetic compatibility. Can be used in a variety of ways
This is understood, including on-site surveys of scheduled locations, technical assessments of equipment and systems, and general information.
This part.
--- introduced the concept of harassment and defined the degree of disturbance of each electromagnetic phenomenon;
---Classify various types of places and describe their attributes;
--- Provides background information on the different electromagnetic phenomena that may exist in the environment;...
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 204 pages — is available in the English PDF.
Referenced standards
Cited by
- GB/T 40286-2021The performance testing method of bi-circulation unit for low-temperature waste heat recovery and utilization
- GB/T 38659.1-2020Electromagnetic compatibility—Risk assessment—Part 1: Electronic and electrical device
- NB/T 10279-2019Warm-damp environmental conditions for power transmission and transformation equipments
- GB/T 19954.2-2016Electromagnetic compatibility - Product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use - Part 2: Immunity
- YD/T 2191.1-2012Installation and mitigation guidelines of Electromagnetic Compatibility (EMC)for Telecommunication Equipments. Part 1: general principles
- YD/T 2191.6-2012Electromagnetic compatibility for installation and mitigation guidelines. Part 6: mitigation of external EM influences
How to Download GB/Z 18039.1-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/Z 18039.2-2000 — Electromagneticcompatibility - Environment - Assessment of the emission levels in the power supply of industrial plants as regards low-frequency conducted disturbances
GB/Z 18039.5-2003 — Electromagnetic compatibility - Environment - Electromagnetic environment for low-frequency conducted disturbances and signalling in public power supply systems
GB/Z 18039.6-2005 — Electromagnetic compatibility-environment-low frequency magnetic fields in various environments
Secure payment via Stripe
Payments accepted
GB/Z 18039.1-2019