Valid

GB/T 7602.4-2017Quantitative determination of T501 oxidation inhibitor content in transformer oil or turbine oil -- Part 4: GC/MS method (English PDF)

Also coversGBT7602.4-2017

Open the GB/T 7602.4-2017 preview as PDF

Preview — first pages of GB/T 7602.4-2017

This is a limited preview

Buy now to download the full PDF

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Recommended

Issue date

November 1, 2017

Implementation date

May 1, 2018

Scope

GB/T 7602.4-2017 (Quantitative determination of T501 oxidation inhibitor content in transformer oil or turbine oil -- Part 4: GC/MS method) is available as an English-translated PDF.

GB/T 7602.4-2017 — GB/T 7602 provisions of this part of the transformer oil, turbine oil added T501 (2,6-di-tert-butyl p-cresol) antioxidant containing Quantitative gas chromatography - mass spectrometry method. This section applies to unused and in operation transformer oil, turbine oil T501 antioxidant content determination.

Document preview — GB/T 7602.4-2017

National Standard of the People's Republic of China

ICS
75.100; 29.040
Classification
E 38

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • Foreword
  • 3.4 The degree of conformity with IEC 60666.2010 is not equivalent.
  • 1 Scope
  • 2 Normative references
  • 3 Method summary
  • 4 reagents and materials
  • 4.3 Dimethyl Phthalate (DMP). Analytical purity.
  • 4.4 Blank oil T501-free mineral insulating oil or turbine oil.
  • 4.5 syringe filter membrane .0.45µm, PTFE material.
  • 4.6 syringe .2.5 mL.
  • 4.7 centrifuge tube .50mL.
  • 4.8 Helium - Purity not less than 99.99%.
  • 5 instruments
  • 5.1 gas chromatograph
  • 0.25 µm.

Foreword

GB/T 7602 "transformer oil, turbine oil T501 antioxidant content assay" is divided into four parts.

--- Part 1. Spectrophotometry;

--- Part 2. Liquid chromatography;

--- Part 3. Infrared spectroscopy;

--- Part 4. GC/MS.

This section GB/T 7602 Part 4.

This section drafted in accordance with GB/T 1.1-2009 given rules.

This section uses the redrafted law reference IEC 60666.2010 "Qualitative and quantitative detection of specific additives in mineral insulating oil" in

3.4 The degree of conformity with IEC 60666.2010 is not equivalent.

This part is proposed by China Electricity Council.

This part of the National Electrochemical Standardization Technical Committee (SAC/TC322) centralized.

This section drafted unit. Guangdong Power Grid Co., Ltd. Electric Power Research Institute, China Petroleum Lanzhou Lubricant Research and Development Center, West

An Thermal Research Institute Co., Ltd., Guangzhou Power Supply Bureau Electric Power Research Institute Ltd., Guangdong Power Grid Co., Ltd. Zhuhai Power Supply Bureau.

1 Scope

GB/T 7602 provisions of this part of the transformer oil, turbine oil added T501 (2,6-di-tert-butyl p-cresol) antioxidant containing

Quantitative gas chromatography - mass spectrometry method.

This section applies to unused and in operation transformer oil, turbine oil T501 antioxidant content determination.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

Electric power oil (mineral insulating oil, turbine oil) sampling method

3 Method summary

This section uses the T501 antioxidants after the transformer oil and turbine oil mass spectrum 205,220 signal peaks appear, and

The peak intensity of this signal is proportional to the concentration of T501. By plotting the standard curve, the T501 in transformer oil and turbine oil

Content, the results with the concentration (%) said.

4 reagents and materials

Iso-octane. Analytical pure.

4.2 2,6-Di-tert-butyl-p-cresol (DBPC, T501). Analytical purity.

4.3 Dimethyl Phthalate (DMP). Analytical purity.

4.4 Blank oil T501-free mineral insulating oil or turbine oil.

4.5 syringe filter membrane .0.45µm, PTFE material.

4.6 syringe .2.5 mL.

4.7 centrifuge tube .50mL.

4.8 Helium - Purity not less than 99.99%.

5 instruments

5.1 gas chromatograph

5.1.1 injection device. With the sample vaporization, diversion and collection of residual oil function.

5.1.2 Capillary column .5% phenylpolysiloxane and 95% methylpolysiloxane stationary phase, length 30m, inner diameter 0.25mm, film thickness

0.25 µm.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

How to Buy GB/T 7602.4-2017

  1. 1Add to cart. Click the "Buy GB/T 7602.4-2017" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 7602.4-2017

$90.00

$75.00for partners