Scope

GB/T 7424.24-2020 is the English-translated version of 光缆总规范 第24部分:光缆基本试验方法 电气试验方法.

GB/T 7424.24-2020 is the Chinese standard "Optical fibre cable generic specification - Part 24: Basic optical cable test procedures. Electrical test methods".

Its scope clause reads: This part of GB/T 7424 specifies the purpose, samples, equipment, procedures, requirements and requirements of each test method for the electrical performance test of optical cables: Specify details, etc: This Part applies to optical cables and optical hybrid cables used in communication equipment and devices using similar technologies: It also applies to optical fiber units, Micro-tube fiber unit, etc:. Its clauses include method h1.

Found what you need?

Document preview — GB/T 7424.24-2020

National Standard of the People's Republic of China

ICS
33.180.10
Classification
M 33
Replacing
GB/T 7424.2-2008

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Foreword
  • 1 Scope
  • 2 Method H1: Short-circuit current test (applicable to OPGW and OPAC)
  • 3 Method H2: Lightning test of overhead optical cables (OPGW and OPAC) along power lines
  • 4 Method H3: Electrical continuity test of metal components of optical cable
  • Appendix A (informative appendix) Structure changes of this part compared with IEC 60794-1-24:2014

1 Scope

This part of GB/T 7424 specifies the purpose, samples, equipment, procedures, requirements and requirements of each test method for the electrical performance test of optical cables:

Specify details, etc:

This Part applies to optical cables and optical hybrid cables used in communication equipment and devices using similar technologies: It also applies to optical fiber units,

Micro-tube fiber unit, etc:

2 Method H1

Short-circuit current test (applicable to OPGW and OPAC)

2:1 Purpose

This test is used to evaluate the characteristics of optical fiber composite overhead ground wire (OPGW) under typical short-circuit current, or to evaluate the short-circuit current on suspension wires:

The impact of current on the performance of attached optical cable (OPAC):

2:2 Sample

2:2:1 OPGW test

2:2:1:1 Two-sample test method

A typical setup with two samples is shown in Figure 1:

Two specimens with a length of at least 10m should be fixed at both ends with suitable hardware: In sample A, one or more thermocouples should be plugged into the light

On the surface of the unit, monitor the temperature of the light unit: In sample B, one or more thermocouples should be attached to the metal wire of OPGW to monitor

OPGW temperature: The light source and optical power meter connected to each end of the tested fiber of sample B should be used to monitor the change of fiber attenuation: Optical fiber

The test length should be at least 100m (when the fiber length is less than 100m, the fiber should be connected in series to meet the test fiber length test):

2:2:1:2 Single specimen test method

Specimens with a length of at least 10m should be fixed at both ends with suitable hardware: One or more thermocouples should be inserted through the twisted layer of OPGW Go to the surface of the light unit and monitor the temperature of the light unit: One or more thermocouples should be attached to the metal wire of the OPGW to monitor the OPGW temperature degree: The light source and optical power meter connected to each end of the fiber under test should be used to monitor the changes in the fiber attenuation: The tested length of the fiber should be at least

100m (when the fiber length is less than 100m, the fiber should be connected in series to meet the test fiber length):

2:2:2 OPAC test

The typical device used to test OPAC is shown in Figure 2:

The OPAC sample with a length of at least 10m is attached to the hanging wire agreed by the supplier and the buyer with suitable hardware: Multiple thermocouples should be attached to the hanging

Online, record the temperature reached during the test: In addition, the light source and optical power meter should be connected to each end of the tested fiber of OPAC to monitor the fiber

Attenuation changes: The tested length of the fiber should be at least 100m (when the length of the fiber is less than 100m, the fiber should be connected in series to meet the requirements

Try fiber length):

YD/T 2554.1 | GB/T 9771.1 | GB/T 20186.1 | GB/T 7424.23 | GB/T 7424.22 | GB/T 7424.21 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 7424.24-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
19 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 7424.24-2020

$150.00