Valid

GB/T 7025.2-2008Lifts -- Main specification and the dimensions arrangements for its cars, wells and machine rooms -- Part 2: Lifts of class �� (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (16 pages)

Need quotation for your management?

Get a formal quotation for GB/T 7025.2-2008 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

December 6, 2008

Implementation date

June 1, 2009

Scope

GB/T 7025.2-2008 (Lifts -- Main specification and the dimensions arrangements for its cars, wells and machine rooms -- Part 2: Lifts of class ��) is available as an English-translated PDF.

GB/T 7025.2-2008 — This section provides an elevator installation category IV desired size, defines a class IV elevator is usually used to transport cargo in 3.2.4.

This section applies to electrical and hydraulic drive lift. The horizontal dimension of the hoistway generally determined by the entrance and a drive way, including with Horizontal and vertical automatic sliding doors of the elevator.

For other parameters, the manufacturer should also be considered. This section applies to all installations with one or two entrances of the car elevator in the new building.

In a related case, it may be as a basis for building with elevator installation. This section contains the main parameters and cars, wells, room type and size inconsistent elevator should consult the manufacturer.

Proposed two bearer type (load per unit area). A series. Table 1 loaded in line with GB 7588-2003 to carry passengers and cargo freight elevators or GB 21240-2007 requirements.

Series B. Load does not meet the specified in Table 1 GB 7588-2003 cargo elevator.

Found what you need?

Document preview — GB/T 7025.2-2008

National Standard of the People's Republic of China

ICS
91.140.90
Classification
Q 78
Replacing
GB/T 7025.2-1997

Issued by: Standardization Administration of China

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 General terms and definitions
  • 3.2 Elevator Type
  • 3.3 Symbol Description
  • 4 Elevator 3 main parameters
  • Size 3
  • 5.1 3 car internal dimensions
  • 5.2 Hoistway size
  • 5.3 Lobby size
  • 5.4 Room size
  • 5.5 Room layout
  • 1 IV class diagram. freight elevators --- Size
  • 3 --- hydraulic elevator hoistway and machine room
  • Graphs 7 IV. freight elevators --- Series B. vertical sliding doors

Foreword

GB/T 7025 "Lifts - Main specifications and cars, wells, room type and size" contains the following three parts.

--- The first part 1. I, II, III, VI type elevator;

Part --- Article 2. IV class elevator;

Part --- Section 3. V class elevator.

This section GB/T 7025 Part 2. This part identical with ISO 4190-2:2001 "elevator installation - Part 2.

IV class elevator "(in English).

For ease of use, this part of ISO 4190-2:2001 made the following editorial changes.

--- The "this part of ISO 4190" with the words "in this section."

--- This section deleted ISO 4190-2:2001 Introduction, because its existence to understand and use this section does not have any influences.

--- In this part of the "Normative references" used instead of the standard ISO 4190-2:2001 corresponding to international standards.

--- Because of the elevator industry specific terminology standard GB/T 7024, therefore, removed the ISO 4190-2:2001 in art 3.3 Terms and definitions. For ease of use, increase of Table 1.

--- Taking into account the actual situation in China, an increase of 4.2 in 3000kg, 4000kg rated load as usual.

--- To coordinate with the relevant standard, delete 5.2.1 allows the design dimensions of the hoistway negative bias content.

This Part replaces GB/T 7025.2-1997 "elevator main parameters and cars, wells, room types and dimensions - Part 2. IV class power ladder".

This portion of the GB/T 7025.2-1997 The main differences are.

--- Technical content and the chapter number by ISO 4190-2:2001 were developed;

--- Remove the ISO foreword;

--- The elevator IV class is divided into A, B series;

--- Priority number system by nearly R10 and R5 determine the rated load and rated speed.

This part of the National Standardization Technical Committee elevator (SAC/TC196) and focal points.

This section is responsible for drafting units. Hitachi Elevator (China) Limited.

Participated in the drafting of this section. Schindler (China) Elevator Co., Ltd., Shanghai Mitsubishi Elevator Co., Ltd., Toshiba Elevator (Shenyang) Co., Division Huasheng Fujitec Elevator Co., Ltd.

1 Scope

This section provides an elevator installation category IV desired size, defines a class IV elevator is usually used to transport cargo in 3.2.4.

This section applies to electrical and hydraulic drive lift. The horizontal dimension of the hoistway generally determined by the entrance and a drive way, including with Horizontal and vertical automatic sliding doors of the elevator.

For other parameters, the manufacturer should also be considered.

This section applies to all installations with one or two entrances of the car elevator in the new building. In a related case, it may be as a basis for building with elevator installation.

This section contains the main parameters and cars, wells, room type and size inconsistent elevator should consult the manufacturer.

Proposed two bearer type (load per unit area).

A series. Table 1 loaded in line with GB 7588-2003 to carry passengers and cargo freight elevators or GB 21240-2007 requirements.

Series B. Load does not meet the specified in Table 1 GB 7588-2003 cargo elevator.

2 Normative references

The following documents contain provisions which, through GB/T reference in this 7025 constitute provisions of this part. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

GB 7588-2003 elevator manufacturing and installation of safety norms (EN81-1:1998, MOD) GB 21240-2007 hydraulic elevator manufacturing and installation of safety norms (EN81-2:1998, MOD)

3 Terms and Definitions

The following terms and definitions apply to this section.

3.1 General terms and definitions

3.1.1

Part of the elevator, to transport passengers and/or other loads.

3.1.2

Part of the hoistway, located above the top of the car service.

3.1.3

Access to each floor for car locations.

3.1.4

Install one or more host and drive ancillary equipment rooms.

GB/T 7025.2-2008/ISO 4190-2:2001

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.

Referenced standards

Normative references

GB 7588-2003 · GB 21240-2007

How to Download GB/T 7025.2-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
16 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 7025.2-2008

$165.00